Skip to content

Does the Structure of the Tendon Relate to the Temporal, Kinetic and Kinematic Jump Variables? Athletes Vs. Non Athletes

Does the Structure of the Tendon Relate to the Temporal, Kinetic and Kinematic Jump Variables? Athletes Vs. Non Athletes: an Observational Study

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06732986
Enrollment
48
Registered
2024-12-13
Start date
2024-03-05
Completion date
2025-09-30
Last updated
2025-02-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Achilles Tendon, Patellar Tendon, Vertical Jump

Keywords

Vertical jump, Jump performance, Patellar tendon, Tendon structure, UTC, Achilles tendon

Brief summary

The goal of this observational study is to investigate the relationship between temporal, kinetic, and kinematic jump variables and patellar and Achilles tendons' structure in athletes and non-athletes. The main research questions are: Does the structure of the patellar and Achilles tendons relate to the temporal, kinetic, and kinematic jump variables? Does the relationship between these variables differ between athletes and non-athletes? To answer these questions, researchers will compare the two groups to determine if the relationships between the variables are similar. Participants will undergo a UTC (Ultrasound Tissue Characterization) scan of the patellar and Achilles tendons and perform five jumps: a countermovement jump, a single-leg countermovement jump on each leg and a single-leg horizontal jump on each leg.

Interventions

None listed

Sponsors

Escola Superior de Tecnologia da Saúde do Porto
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
18 Years to 35 Years
Healthy volunteers
Yes

Inclusion criteria

for the Athletes Group: 1. Being a volleyball athlete competing in the 1st or 2nd division of the portuguese national championship; 2. Participating in training and games for more than 20 hours per week.

Exclusion criteria

for the Athletes Group: 1. Presence of any musculoskeletal, neurological, cardiorespiratory, or metabolic condition that affects jumping performance; 2. Absence from competition due to injury or illness in the last two weeks; 3. History of tendon rupture; 4. Previous tendon surgery; 5. Diagnosis of patellar tendinopathy in the last 12 months.

Design outcomes

Primary

MeasureTime frameDescription
Tendon StructureBaselineUltrasound Tissue Characterization (UTC) captures tendon structure and quantifies the number of altered fibers. This technology classifies tendon structure into four echo types, reflecting tendon integrity and fibrillar organization. Data collection for the patellar tendon will be conducted with participants seated, hips and knees at 90° flexion, and feet supported on a stable surface. For the Achilles tendon, the participants will be lying down with ankle in neutral position. This positioning ensures the probe is aligned transversely to the tendons, enabling the acquisition of optimal ultrasound images without anisotropy. Ultrasound parameters will be standardized for all scans: a 40-second B-mode ultrasound using a 7-10 Hz linear transducer, with the probe attached to a tracking device that moves automatically along the tendon's perpendicular axis, capturing consecutive images at 0.2 mm intervals. A single scan of the tendons will be performed for each knee.
Jump VariablesBaselineThe data collection protocol includes the following tasks: countermovement jump, single-leg countermovement jump with the dominant leg, single-leg countermovement jump with the jumping leg, single-leg horizontal jump with the jumping leg and single-leg horizontal jump with the dominant leg. Kinematic variables will be analyzed by recording the spatial positions of reflective markers placed on specific anatomical regions. Data will be captured using the Qualisys Motion Capture System (version 2021.2). Ground reaction forces will be measured using a force platform connected to a signal amplifier. The platform records the three components of ground reaction forces-anteroposterior, mediolateral, and vertical-via four sensors. The image capture hardware is connected to the Qualisys USB Analog Acquisition interface, synchronizing temporal, kinetic, and kinematic data with the Qualisys Track Manager (QTM) software.

Countries

Portugal

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026