Skip to content

Thoracoabdominal Artery Stent Graft System Exploratory Study

Exploratory Study of Thoracoabdominal Artery Stent Graft System in the Treatment of Thoracoabdominal Aortic Aneurysms

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06710938
Enrollment
11
Registered
2024-11-29
Start date
2025-07-24
Completion date
2032-06-30
Last updated
2026-05-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Thoracoabdominal Aortic Aneurysms

Keywords

Thoracoabdominal Aortic Aneurysms, G-branch Stent Graft, Lifetech Scientific, Thoracoabdominal Artery Stent Graft System

Brief summary

This study is designed as a single-center, prospective, single-arm, open-label, exploratory study. The objective is to evaluate the feasibility of Thoracoabdominal Artery Stent Graft System for endovascular treatment of Thoracoabdominal aortic aneurysms (TAAA).

Detailed description

Thoracoabdominal Aortic Aneurysms involve both thoracic and abdominal aortic arteries, as well as abdominal aortic aneurysms above the renal arteries. The treatment of TAAAs is complicated because the disease involves multiple visceral arteries. Traditional methods of treatment of TAAA include open surgery and hybrid surgery. The early postoperative mortality, as well as postoperative complications such as respiratory failure, renal failure, and other vital organ complications are concern for open surgery, which makes the benefit-risk ratio of traditional open surgery remains unsatisfactory. In addition, open surgery requires thoracoabdominal incision which will result in huge wound and the reconstruction of visceral artery is also complicated. Hybrid surgery, comprised of an initial open visceral debranching procedure followed by endovascular aneurysm exclusion, is another treatment option. Although hybrid surgery can reduce the huge wound caused by thoracotomy, it does not seem to result in lower complication rates at early and midterm follow up. With the rapid development of endovascular treatment technology, endovascular therapy is also applied in the treatment of TAAA, and gradually becomes one of the main treatment method. Especially for patients with high surgical risk because of comorbidities, an endovascular solution may be preferable. Total endovascular aneurysm repair (t-EVAR) without debranching surgery does not require thoracotomy and laparotomy and could improve the outcomes of these patients. t-EVAR includes fenestrated EVAR (f-EVAR), multi-branched EVAR (b-EVAR), and physician-modified fenestration endograft (PMFG). Compared with open surgery and hybrid surgery, endovascular therapy has the following advantages: 1) minimally invasive surgery, avoiding thoracic and abdominal incision; 2) avoiding aorta occlusion during the operation so that reduce various visceral ischemia complications; 3) reducing intraoperative blood loss and hospital stay; 4) reducing spinal cord complications. The TAAA stent graft system used for endovascular treatment generally consists of a stent graft and a delivery system. Stent graft, also known as artificial stent-type vascular graft, is generally composed of tubular covered and metal wire braided stent. The stent can be compressed into the sheath which delivers the stent to the lesion site of TAAA, and then is released from the sheath. The stent opens by its own expansion force to separate the blood from the lesion site, so as to achieve the treatment purpose. Custom made stents need to be designed and manufactured according to the patient's aortic characteristics, and the 6-8 week waiting period limits its use in patients who show precursors to rupture or who have already ruptured. Currently commercially available off-the-shelf multibranched stent grafts for TAAA include Zenith t-Branch stent (Cook), E-nside TAAA Multibranch Stent Graft System (Jotec) and GORE® EXCLUDER® Thoracoabdominal Branch Endoprosthesis (Gore & Associates). A critical issue with these multibranched stent grafts is the limited device specification and suboptimal anatomical feasibility for TAAA patients, therefore, improvements to the device profile, configuration and size optimization are needed. In the current context, Lifetech have developed a new TAAA stent graft system, Thoracoabdominal Artery Stent Graft System, which is a mixed branch design with two inner branches for the visceral arteries and two outer branches for the bilateral renal arteries. It is an off-the-shelf multibranched endograft and there is no need to waste time on customisation. The variations in the main body diameter, length and branch size, introducing diversified configurations that accommodate more anatomic conditions. Two inner branches are integrated with preloaded guidewires to facilitate visceral artery cannulation and reduce the procedure time. The semi-release design allows the stent position to be adjusted during the release process, making the stent positioning more accurate and less difficult. This study is an exploratory study aimed to assess the feasibility of the Thoracoabdominal Artery Stent Graft System.

Interventions

DEVICEThe system includes the G-Branch™ thoracoabdominal aortic stent graft system, the peripheral vascular stent graft system, and the aortic extension stent graft system

The thoracoabdominal artery stent graft system is a mixed branch design with two inner branches for the visceral arteries and two outer branches for the bilateral renal arteries.

Sponsors

Lifetech Scientific (Shenzhen) Co., Ltd.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DEVICE_FEASIBILITY
Masking
NONE

Intervention model description

Thoracoabdominal Artery Stent Graft System. The system includes the G-Branch™ thoracoabdominal aortic stent graft system, the peripheral vascular stent graft system, and the aortic extension stent graft system.

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

1. Age: 18 to 80 years old; 2. Patients diagnosed with a Thoracoabdominal aortic aneurysm (based on the modified Crawford classification and European Society for Vascular Surgery (ESVS) 2019 Clinical Practice Guidelines on the Management of Abdominal Aorto-iliac Artery Aneurysms), and should meet at least ONE of the following conditions: 1. Maximum diameter of TAAA is \>50 mm; 2. TAAA diameter increases by more than 5 mm in the past 6 months or by more than 10 mm in the past 1 year; 3. Definite symptoms associated with TAAA, such as abdominal pain and back pain. 3. Anatomical Criteria 1. Proximal landing zone (aorta or implanted graft): the diameter ranges from 17 to 36 mm, and length should be ≥25 mm; 2. Distal landing zone (aorta or implanted graft): If distal landing zone is in iliac artery, distal landing zone diameter ranges from 7 to 25 mm, and length should be ≥15 mm; If the distal landing zone is in the abdominal aorta, distal landing zone diameter ranges from 12 to 36 mm, and length should be ≥20 mm. 3. Visceral branch landing zone: the diameter ranges from 6 to 13 mm, and the length should be ≥15 mm; 4. Renal artery landing zone: the diameter ranges from 4.5 to 9 mm, and the length should be ≥15 mm; 5. Appropriate iliac, femoral, and upper limb arterial access. 4. Patients who understand the purpose of the study, volunteer to participate and sign the informed consent form, and are willing to complete follow-up as required by the protocol; 5. Patients do not want to or cannot wait for the approved alternative

Design outcomes

Primary

MeasureTime frameDescription
Treatment success rateIntraoperative and 12-month post operationTreatment success is a composite index that should meet all of the following criteria: * Immediate technical success: refers to successful delivery of the delivery system to the intended location, successful deployment of the stent graft, withdrawal of the delivery system, with no type I/III endoleak) \[Timeframe: intraoperative\], * No TAAA-related secondary intervention (including secondary intervention due to aneurysm rupture, sustained enlargement, stent migration, type I/III endoleak, branch stenosis/occlusion) \[Timeframe: 12-month post operation\].
Incidence of major adverse events (MAEs): 30-day post operation30-day post operationMAEs are defined as all-cause death, hepatic failure, bowel necrosis, renal failure, stroke, permanent paraplegia, myocardial infarction, and respiratory failure.

Secondary

MeasureTime frameDescription
Incidence of perioperative delivery system-related complicationsintraoperative and within 30-day post operationInclude conversion to open surgery, hemorrhage, hematoma, and pseudoaneurysm of the atrial access.
All-cause mortality6-month, 12-month, and 2- to 5-year post operationAll-cause death is defined as death from any cause during the follow-up period.
TAAA-related mortality6-month, 12-month, and 2- to 5-year post operationTAAA-related death is defined as death due to rupture of TAAA or surgical treatment of TAAA.
Incidence of serious adverse events (SAEs)6-month, 12-month, and 2- to 5-year post operationIf staged reconstruction is performed because of the patient's condition, then the reconstruction should not be a serious adverse event.
Incidence of device-related adverse events6-month, 12-month, and 2- to 5-year post operationAdverse events refer to adverse medical events that occur during a clinical trial, regardless of whether they are related to the investigational device. However, normal postoperative stress reactions, such as fever and constipation, should be distinguished. If events are judged by the investigator as normal postoperative stress reactions, they need not be recorded as adverse events. If staged reconstruction is chosen because of the patient's condition, then the reconstruction should not be an adverse event.
Incidence of increase in maximum diameter of aneurysm >5mm6-month, 12-month post operation
Incidence of type I or III endoleaks6-month, 12-month post operation
Incidence of stent graft migration6-month, 12-month post operationThe evaluation criteria are as follows: 1) the stent graft migration at the follow-up point after operation is more than 10mm compared with the position before discharge, or 2) the migration caused symptoms or required intervention.
Patency rate of branch vessels6-month, 12-month post operationPatency of branch vessels is defined as stenosis ≤50% of the branch vessels.
Incidence of TAAA-related secondary intervention6-month, 12-month, and 2- to 5-year post operationIf staged reconstruction is performed because of the patient's condition, then the reconstruction should not be a secondary intervention.

Countries

Germany

Contacts

CONTACTRae Gong
gongrui@lifetechmed.com(86-755)-86026250-6957

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: May 27, 2026