Skip to content

Change in Task-related Oxygen Uptake After EBV Treatment

Change in Task-related Oxygen Uptake After Bronchoscopic Lung Volume Reduction With Endobronchial Valves

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06702072
Acronym
CROCODILE
Enrollment
20
Registered
2024-11-22
Start date
2025-06-02
Completion date
2028-08-01
Last updated
2026-04-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

COPD

Keywords

COPD, Emphysema, lung volume reduction, endobronchial valves, bronchoscopy

Brief summary

Rationale: Bronchoscopic lung volume reduction using endobronchial valves (EBV) has emerged as a viable treatment option for eligible patients with severe emphysema. In all studies conducted so far, exercise capacity has only been measured using the 6-minute walk distance test (6MWT). It is known that patients with COPD frequently experience problems during ADL, which can lead to avoidance of or care dependency for performing certain tasks and have a significant social impact on their lives. Patients report that it is easier to perform ADLs after EBV treatment. Previously it was found that it was easier for patient to perform these activities after the EBV treatment. However, the physiological load during these ADLs has never been investigated before. Potentially, EBV treatment could improve the metabolic load and consequently symptom perception, thus enhancing the execution of ADLs, which is an important patient-centred outcome. However, this has not been investigated so far. Objective: To investigate the change in exercise physiology during daily activities after EBV treatment. Study design: Observational study in which the study population will be asked to perform some additional test during regular visits for the bronchoscopic lung volume reduction treatment with valves. Study population: Patients with emphysema who are scheduled for a bronchoscopic lung volume reduction treatment using endobronchial valves. Intervention: Not applicable Main study parameters: The change in task-related oxygen uptake measured with a mobile oxygen device during activities of daily life 6 months after EBV treatment.

Detailed description

Rationale: Bronchoscopic lung volume reduction using endobronchial valves (EBV) has emerged as a viable treatment option for eligible patients with severe emphysema. In all studies conducted so far, exercise capacity has only been measured using the 6-minute walk distance test (6MWT). The 6MWT is conducted under laboratory conditions, which weakly correspond to activities of daily living (ADL). It is known that patients with COPD frequently experience problems during ADL, which can lead to avoidance of or care dependency for performing certain tasks and have a significant social impact on their lives. Patients report that it is easier to perform ADLs after EBV treatment. Previously, it was found that it was easier for patient to perform these activities after the EBV treatment. However, the physiological load during these ADLs was not investigated before. This could be measured with a mobile oxygen device which can measure oxygen uptake (VO2) and carbon dioxide production (VCO2) under more functional conditions and thus measure the metabolic load of these activities. Potentially, EBV treatment could improve the metabolic load and consequently symptom perception, thus enhancing the execution of ADLs, which is an important patient-centred outcome. However, this has not been investigated so far. Objective: To investigate the change in exercise physiology during daily activities after EBV treatment. Study design: Observational study in which the study population will be asked to perform some additional test during regular visits for the bronchoscopic lung volume reduction treatment with valves. Study population: Patients with emphysema who are scheduled for a bronchoscopic lung volume reduction treatment using endobronchial valves. Intervention: Not applicable Main study parameters: The change in task-related oxygen uptake measured with a mobile oxygen device during activities of daily life 6 months after EBV treatment. Nature and extent of the burden and risks associated with participation, benefit and group relatedness: This study has no specific benefits for the participating patients and the study also has no major risks.

Interventions

DEVICEEndobronchial valve treatment

Endobronchial valve treatment

Sponsors

University Medical Center Groningen
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

1. Patient is scheduled for a bronchoscopic lung volume treatment using Pulmonx Zephyr Endobronchial Valves; 2. Patient read, understood and signed the Informed Consent Form.

Exclusion criteria

1\) Patients who cannot perform ADL activities without the use of Long Term Oxygen Therapy (LTOT).

Design outcomes

Primary

MeasureTime frameDescription
Task-related oxygen uptake6 months follow upThe change between baseline and 6 months of follow up after EBV treatment in task-related oxygen uptake (VO2) during a set-up daily life activity trail.

Countries

Netherlands

Contacts

CONTACTJorine E Hartman, PhD
j.hartman@umcg.nl0031503619194
CONTACTMarlies van DIjk, MD PhD
0031503619194
PRINCIPAL_INVESTIGATORDirk-Jan Slebos, MD PHD

University Medical Center Groningen

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Apr 30, 2026