Test-retest Correlation in Isokinetic Shoulder Testing

Evaluation of Test-retest Correlation in Isokinetic Shoulder Testing

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06671366
Acronym
ISO2024
Enrollment
32
Registered
2024-11-04
Start date
2024-11-08
Completion date
2025-01-29
Last updated
2025-06-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Isokinetic

Brief summary

This study is a prospective, monocentric interventional clinical study in 30 healthy volunteers. The aim is to objectively assess shoulder external and internal rotation strength using a Cybex dynamometer in a specific position (seated with the arm at 45° abduction and 30° elevation). The investigator would like here to determine the reproducibility of measurements in this precise evaluation position, but also to determine reference values in healthy subjects. The results of this study will enable us to improve our management and establish a database for comparison with pathological subjects.

Interventions

DEVICEexternal and internal shoulder rotation using a Cybex dynamometer

Measurement of the reproducibility, in this precise evaluation position, of the results obtained between the different tests carried out 30 minutes apart, and thus the reliability of each measurement in this test. measures : * Concentric internal rotation 60degrees/sec * Concentric external rotation 60 degrees/sec * Concentric internal rotation 180 degrees/sec * Concentric external rotation 180 degrees/sec * Eccentric internal rotation 60degrees/sec * Eccentric external rotation 60degrees/sec

Sponsors

Clinique Saint Jean, France
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Student of the Montpellier School of Physical Therapy * Adult having received informed information about the study and signed the consent form

Exclusion criteria

* Any history of shoulder pathology in the year preceding the tests.

Design outcomes

Primary

MeasureTime frameDescription
Correlation between each measurement at peak torque1hourCorrelation between each measurement at peak torque below, and for each arm (12 correlations) in seated position abduction at 45 and 30 degrees anterior elevation. * Concentric internal rotation 60degrees/sec * Concentric external rotation 60 degrees/sec * Concentric internal rotation 180 degrees/sec * Concentric external rotation 180 degrees/sec * Eccentric internal rotation 60degrees/sec * Eccentric external rotation 60degrees/sec Evaluation of results using an intraclass correlation coefficient (ICC).

Secondary

MeasureTime frameDescription
Data in healthy patients1hourEvaluation of the peak torque of each measurement in healthy patients, have a database.
Establishing the test's external validity1hourValidated external test : 1\) External validity * Differences between dominant arm / weak arm measurements * Differences between eccentric and concentric measurements * Difference between test and retest measurements

Countries

France

Outcome results

None listed