Conventional Versus Automated Bag-based Mechanical Ventilator to Support ARDS Patients

Description of the Performance of the Masi Mechanical Ventilator in a Hospital in Lima: Case Series

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06667375
Acronym
Masi-ARDS
Enrollment
87
Registered
2024-10-31
Start date
2021-01-19
Completion date
2022-12-20
Last updated
2024-10-31

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Acute Respiratory Distress Syndrome (ARDS)

Keywords

Ventilators, Medical devices,, Data analysis, Technological innovation

Brief summary

This study evaluates the extubation success and compares the survival rate in patients with signs of Covid-19 intubated with Masi, a novel type of mechanical ventilator, or with other conventional ventilators admitted in the ICU of a reference hospital in Lima, Peru between January and August 2021. The Masi mechanical ventilator works by automating a resuscitation bag with promising preclinical results. The key features of Masi are its low manufacturing cost, low dependence on a supply of high volumes of oxygen, low oxygen consumption, flexibility between non-invasive and invasive ventilation, and extended range of working environmental altitudes compared to commercially available ventilators. A retrospective study of variables and outcomes was done. The main goal of this study is to compare the survival rate of respiratory failure patients supported either with Masi or conventional ventilators at Hospital Vitarte II in Lima between January and August 2021.

Detailed description

The translation of novel technologies for Intensive Care Units (ICU) including mechanical ventilators has been mostly about incremental improvements through increasing features assuming the presence of highly trained personnel and dedicated infrastructure such as permanent power supply and high oxygen flow. Despite the long history of use of mechanical ventilators, the Covid-19 pandemic demanded innovation to meet worldwide demands for this type of life support equipment. The inadequacy of the commercially available ventilators has been mostly attributed to weak fabrication and supply chains and inconsistencies between the required sanitary infrastructure and human resources available for which most commercial ventilators have been designed. Diverse approaches addressed the design and development of low-cost and more available mechanical ventilators worldwide achieving various levels of clinical implementation. In Peru, the Masi (companion in Quechua) ventilator was developed based on concepts of the MIT Emergency Ventilator (MIT E-Vent) by automating a resuscitation bag. The Masi initiative showed promising pre-clinical results that allowed the production of more than 250 units under an exceptional permit to be used clinically in Peru only when no other ventilators were available. The key features of this technology are its low manufacturing cost, low oxygen consumption, flexibility between non-invasive and invasive ventilation, and extended range of working environmental altitudes compared to commercially available ventilators. Clinical characteristics, blood chemistry information, respiratory parameters, and survival rates were analyzed for 77 patients (42 ventilated by Masi, 35 ventilated by commercial ventilators). This is an observational retrospective cohort study. The study protocol was approved by the Research Ethics Committee for Life Sciences and Technology of the PUCP (002-2021-CEICVyTech/PUCP) on September 23, 2021. A total of one hundred and three (103) patients were admitted to the ICU between January 19, 2021 until August 27, 2021, which coincides with the second Peruvian wave of the Covid-19 pandemic in the Hospital Vitarte II in Lima, Peru. Data from patients who were diagnosed with Covid-19, with signs of Acute Respiratory Distress Syndrome (ARDS), intubated, and connected to a mechanical ventilator in the ICU were de-identified for this study. From the 132 variables collected into the Electronic Health Records, only 120 selected variables were transcribed into an electronic database (Microsoft Excel V). The data was standardized and entered by a physician trained in Good Clinical Practice (Data Entry Investigator) following a Data Dictionary. After data cleanup, this study retrospectively analyzed data from eighty-seven (87) patients who had a positive Covid-19 diagnosis and used a mechanical ventilator machine. According to the Peruvian regulatory agency, DIGEMID, Masi was indicated only when no conventional ventilator was available, and a patient needed one as determined by the ICU physician. The physicians used their criteria to prescribe Masi or other available ventilator brands. During the described period, the ICU of the Hospital Vitarte II had seven beds and four conventional ventilators: Evolution (EVL100001-T-NF), Vela (16532-07), Newport (e360) and Dragger (Savina 300). Eight new individually validated ventilators known as Masi were provided to the ICU, and the medical personnel were trained regarding its clinical use. This device was approved to be used in Peru during the sanitary emergency by the local competent authority: Dirección General de Medicamentos, Insumos y Dispositivos Médicos (DIGEMID, Spanish acronym) based on preclinical evidence of safety. To avoid bias derived from the convenience sampling of a single-site study, the Data Entry Investigator reviewed the medical charts corresponding to every patient (n=103) admitted into ICU at the site during the study range across Masi before selecting the charts to be included. A selection was made from the initial 132 variables recorded based on relevance for the present study. Variables from the initial database were uploaded into R studio. The variables and values were reviewed by two independent data analysts and queried to the data entry assistant when necessary. The dataset was cleaned up, and variables were normalized and categorized. Each variable was evaluated with a univariate analysis followed by a bivariate analysis comparing different results between pre- and post-intubation, and post and last-intubation measurements. The main factors used for comparison were the respiratory parameters before and after the intubation between the mechanical ventilators Masi versus conventional. An additional analysis was done to compare survival rates by using the Kaplan-Meier estimator and COX analysis. A sensitivity analysis was done to each model to evaluate suitability for a non- parametric and semi-parametric test.

Interventions

None listed

Sponsors

EsSalud Hospital Vitarte (HOSPITAL II VITARTE ESSALUD)
CollaboratorUNKNOWN
Fanny Lys Casado Pena
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients hospitalized to ICU requiring mechanical ventilation during COVID-19 pandemic * Over 18 years old

Exclusion criteria

\- None

Design outcomes

Primary

MeasureTime frameDescription
ICU discharge statusPatients were followed 15 days (median)After being in the ventilator in the ICU what happened at extubation or censoring time.

Secondary

MeasureTime frameDescription
Ventilator parameter: Oxygen Saturation (%)Patients were followed up 15 days (median)Comparing Oxygen Saturation(%) between ventilators.
Ventilator parameter: Respiratory rate (breaths/minute)Patients were followed up 15 days (median)By comparing Respiratory rates between ventilators.
Ventilator parameter: PaO2/FiO2 ratioPatients were followed up 15 days (median)Comparing PaO2/FiO2 ratio between ventilators.
Ventilator parameters: Tidal volumen (mL)Patients were followed up 15 days (median)Comparing Tidal volumen between ventilators
Ventilator parameters: PIP (mmHg)Patients were followed up 15 days (median)Comparing PIP values between ventilators.

Countries

Peru

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026