OM2 Low Saturation Verification

Low Saturation Verification of Investigational Pulse Oximetry Devices in Adult Volunteers

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06661889
Enrollment
28
Registered
2024-10-28
Start date
2024-11-18
Completion date
2025-05-27
Last updated
2026-05-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hypoxia

Keywords

Low Saturation, Pulse Oximetry

Brief summary

The verification of an investigational pulse oximetry board to verify pulse rate and saturation accuracy over a specified saturation range in diverse populations.

Detailed description

To verify the SpO2 and pulse rate accuracy in comparison to a reference standard blood measurements. To achieve paired observations of SpO2 and SaO2 values over the specified SpO2 accuracy range of the prototype pulse oximeter on a group of healthy adult volunteers. The fraction of inspired oxygen (FiO2) delivered to test subjects is varied to achieve a series of targeted steadystate saturation periods. In this study, the investigational pulse oximetry PCBA system saturation measurements will be compared to saturation measurements made by a multi-wavelength CO-oximeter, taken from arterial blood samples from a diverse pool of healthy human subjects.

Interventions

None listed

Sponsors

Medtronic - MITG
Lead SponsorINDUSTRY

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 39 Years
Healthy volunteers
Yes

Inclusion criteria

1. Healthy volunteers 18 to ≤39 years 2. Subject is willing and able to comply with study procedures and duration 3. Subject is willing to sign an informed consent 4. Subject weighs \>40kg 5. Subject is a non-smoker or has not smoked within 2 days prior to the study 6. Cleared same day health assessment form and health screening

Exclusion criteria

1. Subject is considered as being morbidly obese (defined as BMI \>39.5) 2. Compromised circulation, injury, or physical malformation of fingers, hands, ears or forehead/skull or other sensor sites which would limit the ability to test sites needed for the study (Note: Certain malformations may still allow subjects to participate if the condition is noted and would not affect the sites utilized) 3. Subjects of childbearing potential who are pregnant, who are trying to get pregnant, or who have a urine test positive for pregnancy on the day of the study 4. Subjects with known concurrent, active respiratory conditions such as: 1. uncontrolled / severe asthma 2. flu or influenza type infection 3. pneumonia / bronchitis 4. shortness of breath / respiratory distress 5. unresolved respiratory or lung surgery 6. emphysema, COPD, lung disease 7. recent COVID (last 2 months) 5. Subjects with known heart or cardiovascular conditions such as: 1. hypertension: systolic \>140mmHg, or Diastolic \>90mmHg on 3 consecutive readings 2. have had cardiovascular surgery 3. chest pain (angina) 4. heart rhythms other than a normal sinus rhythm and/or with respiratory sinus arrhythmia, at the discretion of the Principal Investigator or designee 5. previous heart attack 6. blocked artery 7. unexplained shortness of breath 8. congestive heart failure (CHF) 9. history of stroke 10. transient ischemic attack 11. carotid artery disease 12. myocardial ischemia 13. myocardial infarction 14. cardiomyopathy 15. implantable active medical device such as pacemaker or automatic defibrillator 6. Self-reported health conditions as identified in the Health Assessment Form 1. diabetes 2. uncontrolled thyroid disease 3. kidney disease / chronic renal impairment 4. history of seizures (except childhood febrile seizures) 5. epilepsy 6. history of unexplained syncope 7. recent history of frequent migraine headaches 8. recent symptomatic head injury, within the last 2 months 9. cancer requiring chemotherapy, radiation, or current treatment 10. subjects with known clotting disorders 11. history of bleeding disorders or personal history of prolonged bleeding from injury 12. history of blood clots 13. hemophilia 14. sickle cell trait or disease 15. current use of blood thinner: prescription or daily use such as aspirin 16. subjects with Severe contact allergies to standard adhesives, latex or other materials found in pulse oximetry sensors, ECG electrodes, respiration monitor electrodes or other medical sensors 17. participants with severe allergy to iodine (only applicable if iodine is used) 18. subjects with prior or known severe allergies to lidocaine (or similar pharmacological agents, e.g. Novocain) or heparin 19. arterial cannulation within the last 30 days prior to study date, (this may exclude only one radial artery site, left or right) 20. history of clinically significant complications from previous arterial cannulation 21. unwillingness or inability to remove colored nail polish or colored artificial nails other than clear from test digits 22. other known health condition, upon disclosure in Health Assessment form

Design outcomes

Primary

MeasureTime frameDescription
Verification of Saturation Accuracy2.5 hoursVerification of Saturation Accuracy Saturation accuracy in a diverse subject population over a specified saturation range. The acceptance criteria for SpO2 during low saturation conditions across the saturation range of 60-80%: SpO2 Max-A ±3% (ARMS) Max-N ±3% (ARMS) OxySoft-N ±3% (ARMS) Max-Fast ±3%(ARMS)
Acceptance criteria for SpO2 accuracy across the saturation range of 70-100%:2.5 hoursVerification of Saturation Accuracy Saturation accuracy in a diverse subject population over a specified saturation range. The acceptance criteria for SpO2 during saturation conditions across the saturation range of 70-100%: SpO2 Max-A ±2% (ARMS) Max-N ±2% (ARMS) OxySoft-N ±2% (ARMS) Max-Fast ±2%(ARMS)
Acceptance criteria for pulse rate accuracy within 20-250 BPM2.5 hoursPulse rate accuracy Max-A \<=3 BPM (ARMS) Max-N \<=3 BPM (ARMS) OxySoft-N \<=3 BPM (ARMS) Max-Fast \<=3 BPM(ARMS)

Countries

United States

Contacts

PRINCIPAL_INVESTIGATORRandall M Clark

Medtronic Clinical Physiology Laboratory

PRINCIPAL_INVESTIGATORDavid Macleod

Duke University

Outcome results

None listed