Skip to content

The Impact of Soft Contact Lenses on the Corneal Neuromediators and Optical Quality in High Myopia Prior to SMILE

The Impact of Soft Contact Lenses on the Corneal Neuromediators and Optical Quality in High Myopia Prior to SMILE

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06650306
Enrollment
80
Registered
2024-10-21
Start date
2024-10-18
Completion date
2026-06-30
Last updated
2024-10-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Contact Lens Complication

Keywords

Corneal Neuromediator, Soft contact lenses, Corneal optical density, Corneal aberration

Brief summary

To investigate the influence of Neuromediators expression in corneal stromal lenticules and corneal injury repair after small incision extraction

Detailed description

This study included 160 eyes from high myopia patients who underwent Small Incision Lenticule Extraction. Patients were devided into three groups based on duration of wearing SCLs: \> 10 years group, ≤ 10 years group, and NW group (not SCLs). Corneal higher-order aberrations and densitometry were evaluated using a Pentacam system. Neuromediator levels in corneal stromal lenticules were analyzed using ELISA and immunofluorescence

Interventions

This study does not involve any interventions

Sponsors

yuhao shao
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 45 Years
Healthy volunteers
Yes

Inclusion criteria

* age ≥ 18 years with stable refraction for at least two years; * spherical equivalent (SE) \< -6.00 D; * corrected distance visual acuity of 20/20 or better; * no history of using rigid gas permeable lenses or orthokeratology (OK) lenses prior to examination

Exclusion criteria

\- a history of moderate to severe dry eye as well as any ocular or systemic disease that would contraindicate laser refractive surgery.

Design outcomes

Primary

MeasureTime frameDescription
Corneal stromal lenticule NeuromediatorsbaselineCorneal neuromediators, including NGF(pg/mL), CGRP(pg/mL), SP(pg/mL), IGFBP-1(ng/mL), and MANF(pg/mL), which play pivotal roles in maintaining normal physiological functions of the cornea.

Secondary

MeasureTime frameDescription
Corneal AberrationbaselinePreoperative corneal aberration measurements were performed using a Scheimpflug tomography system (Pentacam; Oculus GmbH, Wetzlar, Germany). Images of the highest quality (designated as OK) were selected for analysis. The coefficients for a standardized diameter of 8 ?mm were examined, followed by an assessment of the clinical significance of total higher-order aberrations (HOA, mm), spherical aberration (Z4, 0, mm), horizontal coma (Z3, 1, mm), vertical coma (Z3, -1, mm), horizontal trefoil (Z3, 3, mm), and oblique trefoil (Z3, -3, mm) in relation to visual quality.
Corneal DensitometrybaselineThe Pentacam HR was used to collect data on corneal densitometry values, which were expressed in grayscale units (GSUs), playing a crucial role in quantifying corneal clarity by monitoring transient haze-like reactions. The cornea was divided into four annular zones (0-2 mm, 2-6 mm, 6-10 mm, and 10-12 mm), each exhibiting distinct corneal densitometry values. Based on the anatomical layers of the cornea at different depths, it consists of four layers: a superficial anterior layer of 120 μm, a posterior layer located within the innermost part of the cornea measuring 60 μm; central layers calculated by subtracting thickness of the anterior and posterior layers from the total layer thickness; and a total layer. Corneal densitometry values were measured in the 0-2 mm and 2-6 mm to correspond to the corneal optical zone diameter of SMILE.

Countries

China

Contacts

Primary Contactmin Li, Dr
rgswan@163.com+86 18817367841
Backup ContactYuhao Shao, MD

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026