Skip to content

Miniscrews Placement for Orthodontic Anchorage

A Retrospective Observational Mono-center Study Of Miniscrews Placement For Orthodontic Anchorage

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06635304
Enrollment
40
Registered
2024-10-10
Start date
2025-01-07
Completion date
2025-06-30
Last updated
2025-02-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Miniscrew Placement, Third Palatal Ruga

Keywords

Miniscrews, Third palatal ruga

Brief summary

The goal of this retrospective observational mono-center study is to evaluate inter- and intra-operator variability and accuracy in miniscrews placement compared to CBCT-guided planning. The main questions it aims to answer are: * Is there inter- and intra-operator variability in miniscrews placement? * Is CBCT-guided placement more accurate than direct technique? * Is there consistency among operators in identifying the third palatal ruga? * Is there an influence of palatal vault morphology on these results? The study will be conducted on a sample of 736 cases, that underwent digital planning for palatal mini-implants with the superimposition between the virtual model of the arch and the CBCT or latero-lateral teleradiography. The sample will be provided by a specialist in the field (Professor Giuseppe Perinetti, Adjunct Professor at Vita-Salute San Raffaele University) in anonymized form. From this sample the virtual models, that meet inclusion and exclusion criteria, will be selected and divided in two subgroups according to the palatal vault morphology (deep/flat) using the Korkhaus Index, which relates the distance between the first molars (specifically between the intersection point of the transverse groove and the buccal groove of each first molar) and the height of the palatal vault (i.e., the length of a vertical line perpendicular to the median palatal suture and the previously drawn line) setting the cutoff to determine the depth of the palatal vault at 42%. Below this percentage, the vault is considered flat; above this percentage, it is considered deep. The operators involved will be orthodontists with varying levels of experience. At two different times, using Meshmixer software, they will digitally place a miniscrew in the left hemi-palate of each model and identify the most medial and lateral point of third palatal ruga. The placement of the miniscrews will be repeated by the same operators on the same models after a period of time. Before proceeding with the placement, they will be instructed on the clinical references for positioning palatal mini-implants and on the use of Meshmixer software. Two trial placements will be proposed to make operators familiarize with the software and the described positioning parameters in the presence of an expert clinician. The most adopted references in the literature, which will be therefore illustrated, are as follows: * Placement at the third palatal ruga or up to 2 mm posteriorly, specifying that some authors discourage positioning directly over the third palatal ruga due to the risk of incorrect mini-implant angulation during insertion * A distance from the midline ranging from 3 to 5 mm * Regarding the inclination of the mini-implant, it was specified that Wilmes and co-authors recommend inserting it perpendicularly to the occlusal plane, although this parameter was not considered; what truly matters is the point where the mini-implant penetrates the bone. The identification of the third ruga and the positioning of the mini-implant will occur at different times and in random order. Data collected will be analyzed through statistical methods.

Interventions

None listed

Sponsors

IRCCS San Raffaele
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Completeness of data and records * Good quality of available records, particularly models and CBCT * Healthy patients * Digital planning performed using CBCT * Placement of orthodontic mini-implants in the anterior paramedian area of the palate

Exclusion criteria

* Craniofacial anomalies and congenital syndromes (such as cleft lip and palate) * Cysts and tumors of the jaws * Presence of impacted teeth * Presence of several palatal ectopias of the teeth

Design outcomes

Primary

MeasureTime frameDescription
Inter- and intra-operator variability and accuracy in miniscrews direct placement compared to CBCT-guided planningBaseline, up to 1 monthFor each model, miniscrew coordinates (as placed by recruited orthodontists) will be recorded. To this purpose, all models will be prepared using Meshmixer software (version 3.5; Autodesk Inc) by positioning the Y-axis reference on the median palatal suture and considering the center of the Cartesian coordinate system at the most distal point of the incisive papilla. Miniscrew position and reference position planned with CBCT will be statistically compared using parametric or non-parametric tests depending on the normality of the data. Miniscrew placement will be repeated on the same models by the same operators within 1 month after.

Secondary

MeasureTime frameDescription
Consistency among operators in identifying the third palatal rugaImmediatly after the procedureFor each model, recruited orthodontists will identify the most medial and the most lateral points of the third palatal ruga.

Other

MeasureTime frameDescription
Influence of palatal vault morphology on primary and secondary outcomeThrough study completion, an average of 6 monthsFor each model, palatal vault morphology (deep/flat) will be assessed according to Korkhaus index.

Countries

Italy

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026