Skip to content

Controlled Desaturation Study for TipTraQ SpO2 Performance Validation

Accuracy of Pulse Oximeters with Profound Hypoxia

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06634693
Enrollment
12
Registered
2024-10-10
Start date
2023-10-10
Completion date
2023-10-11
Last updated
2024-10-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hypoxia

Keywords

SpO2

Brief summary

The objective is to validate the performance of SpO2 measurement of the TipTraQ by comparing it with measurement from an artery blood sample of a healthy volunteer in a controlled desaturation study. The overall framework of the validation process followed Annex EE.2 of ISO 80601-2-61:2019.

Detailed description

The TipTraQ, is a finger-based wearable for aiding OSA diagnosis at home that consists of a sensor placed on a fingertip. PPG data are produced by a reflective emitter and photodetector elements from one of the fingertips. TipTraQ Companion app can read and record the PPG signals from the TipTraQ Sensor and further transmit the data to TipTraQ Cloud. The overall framework is a controlled desaturation study follows the Annex EE.2 of ISO 80601-2-61:2019. A radial arterial cannula was placed in each subject's left or right wrist for blood sampling and monitoring blood pressure. Each subject had two control blood samples taken at the beginning of each experiment while breathing room air. Hands with pulse oximeters were maintained motionless on arm boards. Hypoxia was then induced to different and stable levels of oxyhemoglobin saturation (between 70-100%) by having subjects breathe mixtures of nitrogen, air, and carbon dioxide controlled by the study physician by adjusting gas flows with valves according to breath-by-breath estimates of oxygen saturation calculated from end-tidal PO2 and PCO2. Each plateau level of oxyhemoglobin saturation was maintained for at least 30 seconds or until reference pulse oximeter readings were stable. During the procedure, the subject is under stationary status. Two arterial blood samples were then obtained approximately 30 seconds apart. Each stable plateau, therefore, was maintained for at least 60 seconds with SpO2 fluctuating by less than 2-3%. The plateaus were nominally at 100%, room air saturation, 93%, 90%, 87%, 85%, 82%, 80%, 77%, 75% and 70%. At least 200 data points were collected for each type of oximeter and probe combination studied.

Interventions

None listed

Sponsors

PranaQ Pte. Ltd.
Lead SponsorINDUSTRY

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 50 Years
Healthy volunteers
Yes

Inclusion criteria

* Participant must have the ability to understand and provide written informed consent * A participant is an adult 18-50 years of age * Participant must be willing and able to comply with study procedures and duration * Participant is a non-smoker or who has not smoked within 2 days before the study.

Exclusion criteria

* Participant is considered as being morbidly obese (defined as BMI \>39.5) * Compromised circulation, injury, or physical malformation of fingers, toes, hands, ears, forehead/skull, or other sensor sites would limit the ability to test sites needed for the study. Tattoos in the optical path would limit the ability to test sites needed for the study. * Participants with known respiratory conditions * Uncontrolled/severe asthma * pneumonia/bronchitis * shortness of breath / respiratory distress, unresolved respiratory or lung surgery, emphysema, COPD, lung disease * Recent COVID (last 2 months) * Participants with self-reported heart or cardiovascular conditions * chest pain (angina) * heart rhythms other than a normal sinus rhythm or with respiratory sinus arrhythmia * previous heart attack * blocked artery * congestive heart failure (CHF)

Design outcomes

Primary

MeasureTime frameDescription
SaO2During the controlled desaturation study, within 1 dayoxygen saturation of arterial blood sample measured by blood gas analysis
SpO2During the controlled desaturation study, within 1 dayPeripheral blood oxygen saturation measured through plethysmography(PPG)

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026