Skip to content

Mechanical Alignment vs Kalipered Kinematic Alignment Total Knee Arthroplasty

A Prospective, Randomized, Single-blinded Clinical Trial Comparing Mechanical Alignment vs Kalipered Kinematic Alignment Total Knee Arthroplasty Using Medacta Spherika

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06617871
Enrollment
95
Registered
2024-10-01
Start date
2024-08-01
Completion date
2028-12-01
Last updated
2026-03-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Knee Arthropathy, Knee Osteoarthritis

Keywords

randomized trial, knee arthroplasty

Brief summary

Knee replacement surgery can be performed in one of two ways. Traditionally the goal was for the new joint to be in a neutral position with respect to the femur (thigh bone). This is called Mechanical Alignment (MA). The neutral position is different than the human knee's natural position, so MA often requires the surgeon to make additional cuts to the ligaments and other soft tissue around the knee. More recently surgeons have started to place the new joint in a position that more closely replicates the natural alignment of the human knee. This is called Kinemetic Alignment (KA). KA can be done without additional soft tissue dissection but the procedure requires a higher level of precision that can be difficult to achieve in every case. Some studies have found no difference in outcomes between MA and KA, whereas others have found KA to be superior. But these were small studies or studies that did not consider patient-rated outcomes.

Detailed description

Up to 20% of patients that report dissatisfaction and chronic pain following Total knee arthroplasty (TKA). Prior research has identified patient demographic, comorbidity, and expectations as factors that are associated with dissatisfaction. Emerging literature has also suggested that surgical factors including component alignment, soft tissue balance, and kinematics may play a role in patient satisfaction, and that modifications to alignment may result in better function than performing soft tissue releases. Personalized alignment strategies have been proposed that aim to more closely recreate native knee morphology and kinematics. Kinematic alignment (KA) describes a technique that aims to restore the pre-arthritic joint surfaces and alignment of the femur and tibia by removing the bone and cartilage thickness that will be replaced by the implant, taking into account cartilage wear. KA can therefore be conceptualized as a resurfacing procedure, wherein native joint surfaces are replaced by prosthetic surfaces but the position and alignment of the joint surfaces are not changed. This contrasts with mechanical alignment (MA), in which implants are positioned perpendicular to the mechanical axes of the femur and tibia in a manner independent of the pre-arthritic joint surfaces, and soft tissue releases are performed to bring limb alignment into mechanical neutral. There have been prior randomized trials comparing kinematic and mechanical alignment, and these have had mixed results regarding the superiority of one approach over the other. The majority of these trials did not use the same operative modality for both groups (manual vs computer-assisted techniques) or did not include relevant patient reported outcomes (PROs). There is a need for a prospective, randomized trial comparing outcomes following kinematic vs mechanical alignment TKA, with the same operative modality used in both groups with inclusion of relevant PROs.

Interventions

PROCEDUREMechanical Alignment (MA)

Primary TKA with the Medacta SpheriKA, utilizing either MA methodology.

PROCEDUREKinematic Alignment (KA) Interventions:

Primary TKA with the Medacta SpheriKA, utilizing either KA methodology.

Sponsors

Northwestern University
Lead SponsorOTHER
Medacta International SA
CollaboratorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Outcomes Assessor)

Intervention model description

1:1

Eligibility

Sex/Gender
ALL
Age
21 Years to 79 Years
Healthy volunteers
No

Inclusion criteria

* Patient undergoing primary TKA with a medially-stabilized SpheriKA knee system * Able to read and understand consent form and PRO instruments and willing to return for follow up visits

Exclusion criteria

* Varus or Valgus malalignment \>15 degrees to mechanical axis * Flexion contracture \>15 degrees or flexion \<90 degrees * BMI \>40 * Revision TKA or other prior knee surgery other than arthroscopy or arthroscopic-assisted ligament reconstruction * Diagnosis or history of any of the following * inflammatory arthritis * infection in study knee * chronic pain * chronic opioid use * metabolic musculoskeletal disorder other than osteopenia/osteoporosis * Patients receiving workers' compensation for study condition * Patients who cannot complete questionnaires in English * Patients with comorbidities preventing surgery * Patients who are not able to provide informed consent

Design outcomes

Primary

MeasureTime frameDescription
6-week Knee Injury and Osteoarthritis - Joint Replacement Score (KOOS-JR)6 weeks postoperativeThe Knee Injury and Osteoarthritis Score - Joint Replacement (KOOS-JR) score; range: 0 (worst knee health) - 100 (perfect knee health)

Secondary

MeasureTime frameDescription
Forgotten Joint Score (FJS)1 year postoperativeForgotten Joint Score (FJS) questionnaire score; range: 0 (worst outcome) - 100 (best outcome)

Countries

United States

Contacts

CONTACTMelissa Shauver, MPH
melissa.shauver@northwestern.edu312-472-6024
CONTACTMegan VanDyke, BSN
megan.vandyke@nm.org312-472-3445
PRINCIPAL_INVESTIGATORAdam Edelstein, MD

Assistant Professor of Orthopaedic Surgery

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Mar 25, 2026