Skip to content

Accuracy and User Performance Evaluation of PixoTest HbA1c Measurement System

Accuracy and User Performance Evaluation of PixoTest HbA1c Measurement System

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06575231
Enrollment
80
Registered
2024-08-28
Start date
2016-07-01
Completion date
2017-06-30
Last updated
2024-08-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabetes, HbA1c

Keywords

HbA1c

Brief summary

To evaluate the accuracy user performance of PixoTest HbAc1 measurement system and to collect feedback from subjects.

Detailed description

According to WHO report, the number of people with diabetes has risen from 108 million in 1980 to 422 million in 2014. Diabetes is a major cause of blindness, kidney failure, heart attacks, stroke and lower limb amputation. In 2012 alone diabetes caused 1.5 million death. Tight glucose control is essential for prevention of complications in people with diabetes. The Diabetes Control and Complications Trial (DCCT) provided direct evidence the relationship between HbA1c level and risks for diabetic complications in diabetes. Based on the results of the DCCT, the American Diabetes Association (ADA) has published recommendations for HbA1c and plasma glucose levels that are widely used. HbA1c testing can be performed at any time of day and without special patient preparation, it is more convenient for patients and even measuring fasting plasma glucose. The ADA recommends measurement of HbA1c (typically 3-4 times per year for type 1 and poorly controlled type 2 diabetic patients, and 2 times per year for well-controlled type 2 diabetic patients) to determine whether a patient's metabolic control has remained continuously within the target range. .Most diabetes patients will go to hospital to measurement HbA1c, but should wait few days for test result. Most diabetes patient maybe not measurement HbA1c so many time per year. The PixoTest HbA1c measurement system can give result for a few minutes at home. The diabetes patient can measure HbA1c at home don't need go to hospital. The PixoTest HbA1c measurement system is defined as the respective reagent system and the corresponding smartphone. It is intended for quantitative measurement of HbA1c in capillary whole blood and use in the home by people with diabetes mellitus as an aid to monitor the effectiveness of diabetes control. This study is designed to test the accuracy and user performance of the Pixotest HbA1c measurement system.

Interventions

DIAGNOSTIC_TESTin-vitro

responding smartphone. It is intended for quantitative measurement of HbA1c in capillary whole blood and use in the home by people with diabetes mellitus as an aid to monitor the effectiveness of diabetes control.

Sponsors

China Medical University Hospital
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Intervention model description

Each subject should draw two tubes of venous blood in the K2-EDTA. One tube should be tested by POC operator as a study participant using the PixoTest POCT System. The other tube takes 1c.c. blood sample from K2-EDTA to analyzed with a comparison method.

Eligibility

Sex/Gender
ALL
Age
20 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. 18 years or older. 2. Willing to participate in the study, able to read and provide written informed consent form. 3. HCT 25\ 65%. 4. Subjects including healthy subjects, outpatients and inpatients.

Exclusion criteria

1. An individual who does not meet the inclusion criteria will be excluded from enrollment.Taking prescription anticoagulants (such as Warfarin or Heparin) or have clotting problems that may prolong bleeding. Taking Plavix or aspirin daily is not excluded. 2. Hemophilia or any other bleeding disorder 3. Reports having an infection with a blood borne pathogen (e.g. HIV, hepatitis)

Design outcomes

Primary

MeasureTime frameDescription
HbA1c3 minutesHbA1c testing can be performed at any time of day and without special patient preparation.

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026