Skip to content

Safety and Efficacy of Persistent Atrial Fibrillation Ablation With a Cryoballoon Technology

Safety and Efficacy of Persistent Atrial Fibrillation Ablation With a Cryoballoon Technology

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06567652
Enrollment
80
Registered
2024-08-23
Start date
2021-01-01
Completion date
2022-09-01
Last updated
2024-08-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atrial Fibrillation

Brief summary

The goal of this retrospective observational study is to learn about the safety and efficacy of cryoballoon catheter ablation in 80 patients with persistent atrial fibrillation using the PolarX (Boston scientific) cryoablation technology. The main question it aims to answer is if it is safe and effective.

Interventions

DEVICEcatheter ablation

All patients underwent pulmonary vein isolation (and eventually left atrial posterior wall isolation) with the POLARx™ cryoballoon system

Sponsors

Universitair Ziekenhuis Brussel
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 90 Years
Healthy volunteers
No

Inclusion criteria

* persistent atrial fibrillation patients undergoing first atrial fibrillation ablation procedure with PolarX cryoballoon

Exclusion criteria

* previous atrial fibrillation ablation or cardiac surgery, * paroxysmal atrial fibrillation, * congenital heart disease, * non-treated coronary artery disease, * intracavitary thrombus, * significant valvular disease, * contraindications to general anesthesia.

Design outcomes

Primary

MeasureTime frameDescription
Effectiveness1 year follow-upPrimary effectiveness failure is defined as the composite of any of the following occurrences: Failure to achieve acute procedural success at the index procedure (pulmonary vein isolation); More than one repeat procedure during the blanking period (within 90 days post-index procedure); Documented atrial fibrillation, or new onset of atrial flutter or atrial tachycardia event (≥ 30 seconds in duration or from a 10 second 12-lead ECG) Repeat procedure for atrial fibrillation, or new onset of atrial flutter or atrial tachycardia Electrical and/or pharmacological cardioversion • Prescribed a new antiarrhythmic drug not documented at baseline Prescribed a higher dose of antiarrhythmic drug documented at baseline
Safety of the procedureThe safety endpoint was evaluated at 7-days 30-days and 1-year follow-upSafety is defined as the composite of any of the following occurrences: Death Myocardial infarction Persistent gastroparesis/injury to vagus nerve Stroke/Transient ischemic attack Thromboembolism/ Air embolism Cardiac tamponade/perforation Pneumothorax Serious vascular access complications\* Pulmonary edema/Heart Failure Ablation related atrioventricular block not attributable to medication effect or vasovagal reaction. Safety events (0-30 days post procedure) Symptomatic pericardial effusion Safety events (0-360 days post procedure) Atrial esophageal fistula Persistent Phrenic nerve injury Pulmonary Vein Stenosis \* Including hematoma requiring intervention or prolongation of hospital stay, artero-venous fistulas or pseudoaneurysm.

Countries

Belgium

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026