Skip to content

Continuous Glucose Monitoring in HIE

Real-time Continuous Glucose Monitoring in Infants With Hypoxic-ischaemic Encephalopathy: a Pilot Randomized Controlled Trial

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06563687
Enrollment
70
Registered
2024-08-21
Start date
2024-08-01
Completion date
2026-12-01
Last updated
2024-08-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hyperglycemia, Hypoglycemia, Hypoxic Ischemic Encephalopathy of Newborn

Keywords

Continuous glucose monitoring, Neonatal hypoglycemia, Neonatal hyperglycemia

Brief summary

The aim of the study is to examine whether the use of continuous glucose monitoring (CGM) to guide the clinical management of glycaemic control will result into an increased time in the target glucose concentration. To further examine the efficacy of using CGM the following secondary outcomes in the two groups were assessed: mean glucose values, glucose variability within individuals, percentage of time that glucose values are in hyperglycaemic or hypoglycaemic ranges. Randomized controlled trial recruiting neonates (Birth weight \>1.8kg, Gestation\>36 weeks) with moderate or severe hypoxic ischemic encephalopathy (HIE) following perinatal asphyxia . Neonates will be randomly assigned (1:1) within 6 hours of birth to receive either the intervention with real-time CGM or standard care for 72 hours.

Detailed description

Neonatal hypoglycaemia and hyperglycaemia are associated with brain injury and impaired neurodevelopment outcomes in neonates with HIE. Improving early glucose control is an important modifiable risk factor for outcomes in this population. Glycaemic monitoring is usually performed by capillary or central line sampling. However, over 30% of the episodes of abnormal glucose concentration are undetected, even with regular but intermittent sampling. CGM can allow earlier detection and prevention of exposure to extreme glucose concentrations. Study design - This is a multicentre interventional, open-label, randomized controlled trial of CGM compared with standard clinical management (control).A total of 70 neonates (Birth weight \>1.8kg, Gestation \>36 weeks and aged \<6hours) with moderate or severe HIE following perinatal asphyxia will be recruited within 6 hours of birth after informed parental consent. Neonates with major congenital malformations, inborn errors of metabolism, congenital infections, imminent death will be excluded. Neonates will be randomly assigned (1:1) to receive either the intervention with real-time CGM for 72 hours or standard care using a randomization program (R package SRS: A Subject Randomization System). We will use the minimization method to control for severity and to achieve balance within recruiting centres. In all the neonates recruited Dexcom ONE+ CGM (Dexcom, San Diego, CA, USA) will be placed soon after study enrollment. The sensors will be inserted in the lateral thigh and continuous measurements will be recorded for 72 h. The CGM device will be calibrated using blood glucose values measured by point-of-care test. CGM calibrations will be performed at least twice a day. CGM data will be downloaded by using Dexcom Studio software on a dedicated computer. In the standard care group, the CGM device will collect glucose data continuously, but the clinical team will be blinded to the data. These neonates will have their glucose control monitored and managed according to standard clinical practice using intermittently sampled blood glucose levels. In the intervention group the CGM data will be used to support clinical management including blood glucose measurements and decision making. Changes in glucose and insulin infusion will be based primarily on the real-time CGM data but blood glucose concentrations will be checked in case of rapid changes in CGM data. Interventions to target glucose control will be guided by a protocol shared among the participating hospitals. As part of the study protocol, all the neonates will receive a continuous infusion of glucose 10% of 3-4 mg/kg/minute and total fluid intake starting at 50-60 ml/kg/day followed by titration depending on urine output, renal function, and management of glucose infusion rates.

Interventions

DEVICEDexcom ONE+

In all the neonates recruited CGM sensor and transmitter will be placed soon after study enrollment. The sensors will be inserted in the lateral thigh and continuous measurements will be recorded for all the duration of therapeutic hypothermia.

Sponsors

University of Campania Luigi Vanvitelli
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
SINGLE (Investigator)

Eligibility

Sex/Gender
ALL
Age
No minimum to 6 Hours
Healthy volunteers
No

Inclusion criteria

* Birth weight \>1.8kg * Gestation \>35 weeks * Aged \<6hours * Moderate or severe HIE following perinatal asphyxia

Exclusion criteria

* Major congenital malformations * Inborn errors of metabolism, * Congenital infections * Imminent death

Design outcomes

Primary

MeasureTime frameDescription
In range - time72 hours after birthProportion of time that the sensor glucose values are in the target range (50 to 180 mg/dL) compared between the study groups

Secondary

MeasureTime frameDescription
Hypoglycemia72 hours after birthPercentage of time below 50 mg/dl
Hyperglycemia72 hours after birthPercentage of time above 180 mg/dl
Glycemic variability72 hours after birthEvaluation of glycemic variability
Adverse events associated to insertion of CGMup to 10 days after birth% of infants with adverse events secondary to CGM placement or wear

Countries

Italy

Contacts

Primary ContactPaolo Montaldo, PhD
paolo.montaldo@unicampania.it0815664023
Backup ContactSimona Puzone, MD
simona.puzone@unicampania.it

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026