Skip to content

Management of COPD Patients With BoraCare® Remote Monitoring Solution Including BVS3 Early Detection Score for COPD Exacerbations

Management of Chronic Obstructive Pulmonary Disease (COPD) Patients With BoraCare® Remote Monitoring Solution Including BVS3 Early Detection Score for COPD Exacerbations

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06523140
Acronym
AUSTRAAL
Enrollment
380
Registered
2024-07-26
Start date
2024-11-20
Completion date
2027-12-31
Last updated
2025-08-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

COPD

Keywords

Remote monitoring, COPD, Prevention, Exacerbations, Patient quality of life

Brief summary

The goal of this clinical trial is to demonstrate the superiority of remote monitoring with the Bora Care solution in patients with COPD and frequent exacerbations (experimental group) compared to conventional follow-up alone (control group) on the total number of hospital days per patient for respiratory deterioration over 12 months of follow-up. The main question it aims to answer is: Does remote monitoring of COPD patients reduce the average annual length of hospitalization for exacerbations of COPD patients? All participants will benefit a conventional clinical follow-up. Participants in experimental group will also benefit from the Bora care remote monitoring system.

Detailed description

Control group (control): conventional follow-up For the target population (frequent exacerbating COPD patients), the usual follow-up includes two consultations with the general practitioner and one consultation with the pulmonologist per year. The inclusion and follow-up visit at 12 months by a pulmonologist are consistent with the follow-up of COPD patients in current practice and the recommendations of HAS (National Authority for Health) and SPLF (French-Language Society of Pneumology). Experimental group (conventional monitoring + remote monitoring): The patients will be subject to conventional clinical follow-up and at the same time benefit from the Bora care remote monitoring system. The Bora care remote monitoring system includes a BoraBand wristband measuring vital signs at home, the Bora Connect platform for caregiver visualization of data and the BVS3 score for early detection of COPD exacerbations. Patients are monitored daily remotely by Case Managers (nurses trained in Bora Care solution), who, when the BVS3 \> 3 alert is triggered on Bora Connect, call the patient to inform the patient about his symptoms, then alert the pulmonologist by transmitting the information from Bora Connect and the minutes of the phone call, who, according to conventional management, decides whether or not to hospitalize the patient, or to generate an unscheduled consultation in order to prescribe drug treatment, and/or to prescribe additional examinations, and/or to adapt the patient's oxygen therapy prescription. The Case Manager re-evaluates the situation after 48 hours and 96 hours if necessary and forwards the information to the pulmonologist. The nature of the transmission of information (telephone or email) between the Case Manager and the pulmonologist in case of an alert is defined when the patient is included by the pulmonologist. If desired, remotely monitored patients will be able to access the Bora Connect interface provided for patients (restricted viewing of data).

Interventions

DEVICEBoracare remote monitoring solution

Bora Band wristband measuring vital signs at home, Bora Connect platform for caregiver visualization and BVS3 early detection of COPD exacerbations

Sponsors

Assistance Publique - Hôpitaux de Paris
CollaboratorOTHER
Biosency
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
NONE

Intervention model description

Comparative, superior, randomised, multicentre, two-arm study (experimental group, control group, 1:1 ratio) in open-label, with a pilot phase Control group: Conventional follow-up: two consultations with the general practitioner and one consultation with the pulmonologist per year. The inclusion and follow-up visit at 12 months by a pulmonologist are consistent with the follow-up of COPD patients in current practice and the recommendations of SAH and SPLF. Experimental group: Patients will receive conventional clinical follow-up and at the same time benefit from the Bora care remote monitoring system. Patients are monitored daily remotely by Case Managers, who, when the BVS3-3 alarm is triggered on Bora Connect, call the patient to inform the patient about his symptoms, then notify the pulmonologist by transmitting the information from Bora Connect. The Case Manager re-evaluates the situation at 48h and 96h if necessary and forwards the information to the pulmonologist.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patient over 18 years of age with COPD defined according to the recommendations of the SPLF, whose level of respiratory function in a stable state is known (measured less than 12 months), recruited in pulmonology * Patient who has been hospitalized for COPD exacerbation in the previous 12 months * Informed patient who has signed consent, * Patient enrolled in a social security scheme (Art L1121-11 of the CSP)

Exclusion criteria

* Presence of a comorbidity considered unstable or very severe by the investigator. * Patient with psychological frailties, * Patient already included in another interventional trial, * Patient who does not speak French and is unable to use the Bora Band tool and without access to a caregiver, * Patient protected under guardianship or unable to give free and informed consent. * Pregnant or nursing woman

Design outcomes

Primary

MeasureTime frameDescription
Demonstrate the superiority of remote monitoring with the Bora Care solution in patients with COPD and frequent exacerbations compared to conventional follow-up.1 yearNumber of hospital days for respiratory deterioration per patient over 12 months.

Secondary

MeasureTime frameDescription
Evaluate the effect of the device on the average length of stay.1 yearAverage length of stay in hospital within 12 months of the implementation of Bora Care.
Assess the overall quality of life of patients at baseline and at the end of the trial. (1)1 yearScore from CAT (Chronic Obstructive Pulmonary Disease Assessment Test) questionnaire to assess the quality of life collected at Day 0, M6, M12.
Assess the overall quality of life of patients at baseline and at the end of the trial. (2)1 yearScore from Short Form 36 (SF36) quality of life assessment questionnaire to assess the quality of life collected at Day 0, M6, M12.
Assess the overall quality of life of patients at baseline and at the end of the trial. (3)1 yearScore from EXACT E-RS (Evaluating Respiratory Symptoms) symptom assessment questionnaire to assess the quality of life collected at Day 0, M6, M12.
Assess the conformity of use of the Bora Care device.3 yearsNumber of hours spent wearing the Bora Connect bracelet normalized by the total number of hours spent in the remote monitoring session, information collected via the Bora Care tool.
Assess the impact of the device on the organisation of care. (1)3 yearsNumber and nature of emergency, resuscitation, consultations and teleconsultations with the pulmonologist or attending physician.
Assess the impact of the device on the organisation of care. (2)3 yearsDuration of emergency, resuscitation, consultations and teleconsultations with the pulmonologist or attending physician.
Evaluate the effect of the device on the number of hospitalizations per patient.1 yearNumber of hospitalizations within 12 months of implementation of Bora Care remote monitoring.
Assess the impact of the device on the quality of support. (1)3 yearsNumber and nature of prescribed pharmacological treatments and prescribed oxygen therapy.
Assess the impact of the device on the quality of support. (3)3 yearsDuration of prescribed pharmacological treatments and prescribed oxygen therapy.
Assess patient and caregiver satisfaction with the device. (1)1 yearSubjective assessment by the patient of the device, the reassurance provided by the device, the assistance to resume physical activity provided by the device, obtained using satisfaction questionnaires at M6 and M12.
Assess patient and caregiver satisfaction with the device. (2)1 yearSubjective assessment by the patient of the overall quality of follow-up obtained using a detailed questionnaire (Likert scale) and an open-ended question about possible improvements at M6 and M12.
Assess patient and caregiver satisfaction with the device. (3)1 yearSubjective assessment by caregivers of the Bora Care solution's impact on patient care using questions about organizational impacts and improved quality of care provided by the device, obtained using a satisfaction questionnaire at M6 and M12.
Evaluate the performance of the warning device in the early detection of exacerbations.3 yearsThe number and nature of the alerts issued by the Bora Care solution, the number and nature of the actions taken following the alert specified in the alert management tool in the Bora Connect tool.
Identify new markers of exacerbations or other clinical events.3 yearsAlert performance in detecting exacerbations and other medical events by calculating alert sensitivity and specificity.
Assess the impact of the device on the organisation of care. (3)3 yearsNumber and nature of follow-up examinations and new pathologies detected during follow-up.

Countries

France

Contacts

Primary ContactAlexis TOULLEC
clinical@biosency.com02 21 65 70 01

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026