Effect of Time Delay and Syringe Surface Area on Blood Gas Samples Analysis

Effect of Time Delay and Syringe Surface Area on Results of Blood Gas Analysis

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06522009
Enrollment
45
Registered
2024-07-26
Start date
2019-07-30
Completion date
2020-07-30
Last updated
2024-08-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Respiratory Failure

Keywords

blood gas, oxygen saturation, syringe surface area, Time Delay

Brief summary

To detect the effect of time delay and syringe surface area on the oxygen tension (PaO2), oxyhaemoglobin saturation (SaO2), acidity (pH), and carbon dioxide tension (PaCO2) in both arterial and venous blood gas outcomes.

Detailed description

Arterial blood gas (ABG) analysis and monitoring is a crucial process for the diagnosis and management of the oxygenation status and acid-base balance of high-risk patients during surgery, as well as for the critical care of critically ill patients in the Intensive Care Unit . Acid-base imbalance anomalies can have major repercussions in a number of medical scenarios, and in a few rare instances, they may even be a risk factor for death. ABG test explores the arterial blood's pH, oxyhaemoglobin saturation (SaO2), bicarbonate concentration (HCO3), oxygen tension (PaO2), and carbon dioxide tension (PaCO2). Traditionally, the concept blood gas testing has been used to describe measuring the blood's pH, oxygen saturation of haemoglobin (SaO2), and partial pressures of the physiologically active gases (pO2, pCO2). But now available commercial equipment can measure electrolytes (sodium, potassium, chloride, ionized calcium, and magnesium), glucose, lactate, and creatinine, usually all at the same time, in addition to haemoglobin quantification and co-oximetry

Interventions

None listed

Sponsors

Theodor Bilharz Research Institute
CollaboratorOTHER
Helwan University
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Critically ill-patients, and intraoperative patients who aged above 18 years.

Exclusion criteria

* Patients with haematological diseases e.g. sickle cell anaemia * burn patients with risk of carbon monoxide poisoning * ARDS * pulmonary oedema * samples that were clotted

Design outcomes

Primary

MeasureTime frameDescription
To detect the effect of time delay and syringe surface area on the oxygen tension (PaO2) arterial and venous blood gas outcomes.1 hourPaO2 by mmhg arterial and venous samples To detect the effect of time delay and syringe surface area on SO2 in arterial and venous samples To detect the effect of time delay and syringe surface area on other parameters of blood gases e.g. PH,CO2

Secondary

MeasureTime frameDescription
effect of delay on analysis oxyhaemoglobin saturation (SaO2) acidity (pH) carbon dioxide tension (PaCO2)60 minutesspao2 by mmhg and paco2 by mmhg

Countries

Egypt

Outcome results

None listed