Skip to content

Performance Study with the SiMoT System for in Vitro Diagnostic Tests

Analytical Performance Study of the Handheld Device Single-Molecule with a Large Transistor (SiMoT) for the Near-patient Testing of Biological Samples

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06518967
Enrollment
50
Registered
2024-07-25
Start date
2024-07-16
Completion date
2025-05-31
Last updated
2025-02-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Non-interventional Analytical Performance Study on Left-over Samples

Brief summary

Advanced and performing technologies able to analyze specific biomarkers for the diagnosis, prognosis and prediction as well as for the monitoring, the personalized care and the evaluation of the therapeutic response to pathologies, is currently considered extremely relevant. Such technologies work only if molecular markers specific for a given pathology have been already validated. This approach is considered of strategic importance for the health and well-being of citizens as well as for the sustainability of public spending. Often, however, the analysis of the markers is carried out on tissues or fluids of the organs involved, being hence quite invasive procedures. In this scenario, it is strategic to develop devices and platforms that allow the analysis of markers in a minimally invasive or non-invasive way, through the analysis of peripheral biological fluids, such as blood or urine. The goal is to provide clinicians with the attacker's advantage against a plethora of progressive diseases by mass-screening individuals who are affected by a disease long before symptoms appear or to allow the identification of those patients who have a high probability of recurring or responding to target-oriented pharmacological approaches. This study pertains to the definition of the analytical performance of the Single-Sensor Single-Molecule with a large Transistor (SiMoT) device. In the context of the present performance study, the IVD SiMoT system will be equipped with an accessory-cartridge developed and produced without any diagnostic purpose but only to verify the analytical performance of the SiMoT system, in the detection of exogenous biochemical molecules suitably selected to act as markers of interest.

Detailed description

Advanced and performing technologies able to analyze specific biomarkers for the diagnosis, prognosis and prediction as well as for the monitoring, the personalized care and the evaluation of the therapeutic response to pathologies, is currently considered extremely relevant. Such technologies work only if molecular markers specific for a given pathology have been already validated. This approach is considered of strategic importance for the health and well-being of citizens as well as for the sustainability of public spending. Among the pathologies that will increasingly be monitored and treated thanks to enabling technologies for precision medicine, tumors are certainly of particular importance. Often, however, the analysis of the markers is carried out on tissues or fluids of the organs involved, being hence quite invasive procedures. In this scenario, it is strategic to develop devices and platforms that allow the analysis of markers in a minimally invasive or non-invasive way, through the analysis of peripheral biological fluids, such as blood or urine. The goal is to provide clinicians with the attacker's advantage against a plethora of progressive diseases by mass-screening individuals who are affected by a disease long before symptoms appear or to allow the identification of those patients who have a high probability of recurring or responding to target-oriented pharmacological approaches. This study pertains to the definition of the analytical performance of the Single-Sensor Single-Molecule with a large Transistor (SiMoT) device. The SiMoT device is an in vitro diagnostic - IVD system (REGULATION (EU) 2017/746, IVDR Art. 2, point 2) that performs decentralized analyses (near-patient testing, such as, for example, patient's home, emergency unit, ambulance) composed of a palm reader completed by machine-learning / artificial-intelligence software. The system works through an accessory (IVDR Art. 2, point 4) represented by a disposable cartridge, which determines the specific diagnostic application based on the molecular markers detected by the accessory. In the context of the present performance study, the IVD SiMoT system will be equipped with an accessory-cartridge developed and produced without any diagnostic purpose but only to verify the analytical performance of the SiMoT system, in the detection of exogenous biochemical molecules suitably selected to act as markers of interest. The present performance study aims to verify the qualitative detection (on/off) of target molecules (both proteins and nucleic acids) with a single molecule threshold in 0.1 mL (10\^-20 M). The threshold is established by the limit of identification (LOI). Analytical performance will be evaluated according to standard statistical approaches such as: analytical sensitivity, analytical specificity, trueness (bias), precision (repeatability and reproducibility), accuracy (resulting from trueness and precision), limits of detection and identification, measurement range, possible linearity, threshold values, including the determination of appropriate criteria for the collection and handling of samples and the control of known endogenous and exogenous interferences, cross reactions. Risk evaluation (Risk-to-Benefits rationale) There are no identifiable physical, psychic and/or social risks for the patients enrolled in the study directly deriving from the procedures that will be followed for the enrollment and collection of the related data.

Interventions

DIAGNOSTIC_TESTanalytical performance study

analytical performance study on left-over samples with the SiMoT IVD system for in vitro diagnostic tests

Sponsors

Centro di Innovazione Regionale in Single Molecule Digital Assay
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Informed Consent and personal data handling consent signed by the subject; * \> 18 years of age * presence of neoplastic or suspected neoplastic pathology at the time of sample collection

Exclusion criteria

* \< 18 years of age * Participation in a clinical trial with an investigational drug or a medical device within the 30 days preceding and during the present investigation.

Design outcomes

Primary

MeasureTime frameDescription
To evaluate the analytical performance in plasma, serum, and urine samples supplemented with non-endogenous molecules (three proteins and two nucleotide sequences) of the SiMoT handheld deviceDecember 2024Qualitative detection of specific marker at single molecule level

Secondary

MeasureTime frameDescription
Duration of analytical analysis performanceDecember 2024To define the time to obtain the test result (time-to-result) for a complete analysis.

Countries

Italy

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026