Skip to content

Hydra Registry - UK

Prospective Observational Study on the Efficacy and Safety of Hydra Transcatheter Aortic Valve

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06507579
Enrollment
250
Registered
2024-07-18
Start date
2024-07-11
Completion date
2027-08-01
Last updated
2026-08-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aortic Valve Stenosis

Keywords

Aortic Valve Stenosis, TAVI, Hydra

Brief summary

The study will evaluate the efficacy and safety of transcatheter aortic valve implantation (TAVI) using the Hydra transcatheter aortic heart valve (THV) series, in patients with severe aortic stenosis up to 1-year after the procedure. This will include an evaluation of the preservation of coronary access post implant by attempting to selectively engage both the right and left coronary arteries through standardised angiographic views. The study will also examine the utility of 72 hours of post discharge remote ambulatory continuous electrocardiogram (ECG) monitoring using the novel Checkpoint Cardio System where it is clinically appropriate.

Detailed description

This is a prospective, observational, multi-centre study. The aim of this study is to collect clinical, procedural, and follow-up data in order to evaluate the efficacy and safety of the Hydra THV series (Vascular Innovations Co. Ltd., Nonthaburi, Thailand). Additionally, the study will conduct the following evaluation: 1. The remote ambulatory cardiac monitoring (rACM) using the Checkpoint Cardio System, consisting of 72 hours of continuous electrocardiogram (ECG) monitoring, will be evaluated post hospital discharge where it is clinically appropriate. 2. Coronary access will be evaluated immediately post-TAVI by attempting to selectively engage both the right and left coronary arteries through standardised angiographic views. This will be done in a sub-set of patients who are either known to have coronary artery disease, did not have coronary angiogram prior to TAVI or where it is felt to be clinically appropriate for other reasons post implant. Following discharge, clinical follow-ups are scheduled at 45 days (±14 days), and 1-year (±30 days).

Interventions

The Hydra device consists of a self-expanding nitinol frame and three bovine pericardial leaflets in supra-annular position.

Sponsors

Sahajanand Medical Technologies Limited
Lead SponsorINDUSTRY
Psephos Biomedica
CollaboratorUNKNOWN

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 99 Years
Healthy volunteers
No

Inclusion criteria

1. Patients with severe aortic stenosis eligible for transfemoral TAVI procedure as per local Heart Team evaluation 2. Full understanding and willing to provide informed consent to study enrolment 3. Age ≥ 18 years

Exclusion criteria

1. Contraindications to TAVI (e.g., anatomically phenotypes, intracardiac mass, thrombus, vegetation, endocarditis) 2. Refusal to provide informed consent to study enrolment 3. Patients with severe aorta or peripheral artery disease precluding transfemoral approach of TAVI 4. Patients with significant calcification of the aortic annulus and in the Left Ventricular Outflow Tract (LVOT), or/and excess calcium within each cusp, or those who are deemed unsuitable for the Hydra THV series based on the clinical judgment of the Investigator.

Design outcomes

Primary

MeasureTime frameDescription
Primary safety endpoint45 daysEarly safety as defined by VARC-3 as composite of: * Freedom from all-cause mortality; * Freedom from all stroke; * Freedom from VARC 3 type 3-4 bleeding; * Freedom from major vascular, access-related, or cardiac structural complication; * Freedom from acute kidney injury stage 3 or 4; * Freedom from moderate or severe aortic regurgitation; * Freedom from new permanent pacemaker due to procedure-related conduction abnormalities; * Freedom from surgery or intervention related to the device.
Primary performance endpoint45 daysDevice success as defined by VARC-3 as composite of: * Technical success; * Freedom from mortality; * Freedom from surgery or intervention related to the device or to a major vascular or access related or cardiac structural complication; * Intended performance of the valve (mean gradient \<20mmHg, peak velocity \<3 m/s, Doppler velocity index ≥0.25, and less than moderate aortic regurgitation).

Secondary

MeasureTime frameDescription
Technical successImmediately after the procedureAs per VARC-3 defined criteria
Cardiovascular mortality45 days, and 1-year
All-cause mortality45 days, and 1-year
All stroke45 days, and 1-year
Disabling stroke45 days, and 1-year
Myocardial infarction45 days, and 1-year
Major vascular complication45 days
Acute kidney injury45 days
New permanent pacemaker implantation due to procedure related conduction abnormalities45 days, and 1-year
New-onset atrial fibrillation45 days, and 1-year
Coronary artery obstruction requiring intervention45 days, and 1-year
Re-hospitalization for procedure- or valve-related causes45 days, and 1-year
Mean aortic valve gradient45 days, and 1-year
Effective Orifice Area (EOA)45 days, and 1-year
Paravalvular leak45 days, and 1-year
New York Heart Association (NYHA) functional class45 days, and 1-year
Change in quality-of-life score assessed by the Kansas City Cardiomyopathy Questionnaire (KCCQ-12)45 days, and 1-yearAssessed by the Kansas City Cardiomyopathy Questionnaire (KCCQ-12)
Bioprosthetic Valve Failure (BVF), defined as valve-related mortality or aortic valve re-operation/re-intervention, or stage 3 haemodynamic severe structural valve deterioration45 days, and 1-year
Bioprosthetic valve dysfunction (BVD), defined as structural valve deterioration, non-structural valve deterioration, clinical valve thrombosis, infective endocarditis45 days, and 1-year
Stroke or peripheral embolism (presumably valve-related, after ruling out other non-valve aetiologies)45 days, and 1-year
VARC-3 Type 3-4 bleeding secondary to or exacerbated by antiplatelet or anticoagulant agents used specifically for valve-related concerns (e.g., clinically apparent leaflet thrombosis)45 days, and 1-year
Significant arrhythmias on rACM that would potentially lead to permanent pacemaker implantation (PPMI)72 hours post hospital discharge
Ability to selectively engage and obtain diagnostic epicardial coronary angiography images from the right and left coronary ostiaImmediately post-TAVI

Countries

United Kingdom

Contacts

CONTACTDr. Javaid Iqbal, MRCP, PhD
J.Iqbal@sheffield.ac.uk7788438471
PRINCIPAL_INVESTIGATORDr. Javaid Iqbal, MRCP, PhD

Northern General Hospital, Sheffield Teaching Hospitals NHS Foundation Trust

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Aug 19, 2026