Skip to content

Patient-Centric Innovation: Superior Vena Cava Approach in Zero-Fluoroscopy

Patient-Centric Innovation: Superior Vena Cava Approach in Zero-Fluoroscopy Radiofrequency Catheter Ablation for Atrioventricular Nodal Reentrant Tachycardia

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06492499
Enrollment
31
Registered
2024-07-09
Start date
2022-10-01
Completion date
2024-06-20
Last updated
2024-07-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atrioventricular Nodal Reentrant Tachycardia

Keywords

Zero-Fluoroscopy, Superior Vena Cava (SVC) Approach, Radiofrequency Catheter Ablation

Brief summary

This study aims to evaluate the viability and therapeutic efficacy of zero-fluoroscopy radiofrequency catheter ablation (RFCA) using the superior vena cava (SVC) approach in patients with atrioventricular nodal reentrant tachycardia (AVNRT). The study compares outcomes between the SVC approach and the conventional inferior vena cava (IVC) approach. Patients diagnosed with AVNRT who underwent RFCA between June 2022 and October 2022 were retrospectively analyzed. The primary outcome measure is the non-inducibility of AVNRT, while secondary outcomes include postoperative recovery time and complication rates. The study seeks to provide a safer and more efficient RFCA method, enhancing patient recovery by minimizing radiation exposure and optimizing catheter access routes.

Detailed description

This retrospective study investigates the feasibility and therapeutic efficacy of zero-fluoroscopy radiofrequency catheter ablation (RFCA) using the superior vena cava (SVC) approach in patients diagnosed with atrioventricular nodal reentrant tachycardia (AVNRT). The study was conducted at our institution between June 2022 and October 2022, including adult patients (age \>18 years) who underwent RFCA during this period. Patients were divided into two groups based on the catheter access site: the SVC approach group and the inferior vena cava (IVC) approach group. The primary objective of the study is to assess the success rate of AVNRT ablation using the SVC approach compared to the conventional IVC approach, under zero-fluoroscopy conditions. Secondary objectives include evaluating the postoperative recovery time, incidence of complications, and overall patient outcomes. Inclusion criteria required that patients experienced at least one episode of AVNRT during transesophageal atrial pacing (TEAP) and programmed stimulation. Exclusion criteria included cases where AVNRT was attributed to reversible causes such as acute myocarditis, cardiac surgery, or other types of tachycardias (e.g., atrial tachycardia, Wolff-Parkinson-White syndrome, ventricular tachycardia). The electrophysiologic study involved TEAP and programmed stimulation to screen for AVNRT and exclude other arrhythmias. The catheterization procedure was performed under conscious sedation and local infiltration anesthesia, with continuous monitoring of vital signs. Catheter access sites for the SVC group included the median cubital vein and the basilic vein, while the femoral vein was used for the IVC group. The ablation procedure utilized a large-tip electrode catheter for mapping and ablation, guided by the EnSite NavX system. Ablation endpoints were determined by the non-inducibility of AVNRT after programmed stimulation. Follow-up evaluations included monitoring for recurrence of atrial arrhythmias or the occurrence of iatrogenic atrioventricular block (AVB). Statistical analysis was performed using R 4.4.0 software, with continuous variables expressed as mean ± SD or median (interquartile range) and categorical variables as counts or percentages. An unpaired t-test or nonparametric test was used to compare the SVC and IVC approach groups, with a p-value of \<0.05 considered statistically significant. This study aims to demonstrate that the SVC approach for zero-fluoroscopy RFCA is a viable and effective alternative to the conventional IVC approach, potentially offering advantages such as reduced postoperative vascular events and elimination of bed rest requirements. The findings could broaden treatment options and enhance patient safety in RFCA procedures. Further research is encouraged to validate these findings across diverse populations and optimize procedural techniques for improved long-term efficacy and minimized risks.

Interventions

PROCEDUREZero-Fluoroscopy Radiofrequency Catheter Ablation

Patients undergo zero-fluoroscopy RFCA for atrioventricular nodal reentrant tachycardia (AVNRT) using the superior vena cava (SVC) or inferior vena cava (IVC) approach. The procedure is performed under conscious sedation and local infiltration anesthesia. A large-tip electrode catheter is used for mapping and ablation, guided by the EnSite NavX system, with ablation parameters set at 40 W power and 50°C temperature.

Sponsors

Ning Zhou
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adults aged \>18 years. * Diagnosed with atrioventricular nodal reentrant tachycardia (AVNRT). * Underwent radiofrequency catheter ablation (RFCA) at our institution between June 2022 and October 2022. * Experienced at least one episode of AVNRT during transesophageal atrial pacing (TEAP) and programmed stimulation. * Provided informed consent for the procedure and data collection.

Exclusion criteria

* AVNRT attributed to reversible causes, such as acute myocarditis or recent cardiac surgery. * Presence of other types of tachycardias (e.g., atrial tachycardia, Wolff-Parkinson-White syndrome, ventricular tachycardia). * Inability to abstain from pharmacological interventions for at least five half-lives of the medication prior to TEAP. * Contraindications for the use of conscious sedation or local anesthesia. * Severe comorbidities that would interfere with study participation or follow-up. * Patients who are pregnant or lactating. * Previous RFCA procedures for AVNRT within the past six months.

Design outcomes

Primary

MeasureTime frameDescription
Non-inducibility of Atrioventricular Nodal Reentrant Tachycardia (AVNRT)During the procedureThis is determined during the procedure by performing programmed stimulation to test for the presence of AVNRT. Non-inducibility is confirmed if AVNRT cannot be induced following the ablation, indicating a successful therapeutic intervention.
Recurrence of supraventricular tachycardiaWithin 1 year post-procedureIt is defined as any documented episode of supraventricular tachycardia, such as AVNRT, atrial fibrillation, or atrial flutter, confirmed by electrocardiographic evidence.

Secondary

MeasureTime frameDescription
Postoperative Recovery TimeWithin 24 hours post-procedureIt is defined as the duration from the completion of the RFCA procedure to the patient's ability to walk unassisted.
Complication RateWithin 1 year post-procedureIt is defined as any documented episode of SVT, including AVNRT, confirmed by electrocardiographic evidence.

Countries

China

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026