Skip to content

Cerebral Blood Flow: Helmet vs Oronasal Mask During Continuous Positive Airway Pressure Ventilation

Variation of Cerebral Blood Flow Depending on the Interface Chosen During Continuous Positive Airway Pressure Ventilation

Status
Not yet recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06480253
Enrollment
19
Registered
2024-06-28
Start date
2024-07-01
Completion date
2024-07-31
Last updated
2024-06-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Ventilation Therapy

Keywords

Continuous Positive Airway Pressure

Brief summary

In this trial the investigators will evaluate blood flow in common carotid artery of healthy subjects treated with Continuous Positive Airway Pressure (CPAP) Ventilation, comparing two different devices: oronasal mask versus Helmet. The hypothesis is that Helmet CPAP reduces carotid flow compared to oronasal mask.

Interventions

DEVICEHelmet Continuous Positive Airway Pressure

Partecipants will be started on Continuous Positive Airway Pressure at 10 cmH2O on inspired fraction of oxygen (FiO2)= 21% with the Helmet interface for a duration of 5 minutes while laying down on a stretcher with head elevated at 60°

DEVICEOronasal Mask Continuous Positive Airway Pressure

Partecipants will be started on Continuous Positive Airway Pressure at 10 cmH2O on Inspired fraction of oxygen (FiO2)= 21% with the oronasal mask interface for a duration of 5 minutes while laying down on a stretcher with head elevated at 60°

Sponsors

Papa Giovanni XXIII Hospital
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

Open Label, randomized, controlled with crossover

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Age ≥ 18 years, * Ability to give informed consent

Exclusion criteria

* known cardiac pathologies * known pulmonary pathologies * known vascular pathologies * history of concussion * history of headache

Design outcomes

Primary

MeasureTime frameDescription
Common carotid artery flow4 consecutive heart beats at the end of the interventionLeft common carotid artery flow, expressed as ml/min measured with pulsed wave doppler with ultrasound

Secondary

MeasureTime frameDescription
Mean arterial blood pressuresingle measure, at the end of the interventionNon invasive mean arterial blood pressure on left arm
Peripheral vascular resistance4 consecutive heart beats at the end of the interventionPeripheral vascular resistance measured in left common carotid artery, measured with pulsed wave doppler with ultrasound

Countries

Italy

Contacts

Primary ContactAndrea Duca, MD
a.duca85@gmail.com+393396980738
Backup ContactRoberto Cosentini, MD
r.cosentini@asst-pg23.it+390352678981

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026