Skip to content

Four-Week Oral Malodor and Clinical Safety for a Concentrated Cosmetic Mouthwash

Four-Week Oral Malodor and Clinical Safety for a Concentrated Cosmetic Mouthwash

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06479096
Enrollment
166
Registered
2024-06-27
Start date
2024-07-15
Completion date
2024-09-12
Last updated
2025-01-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Oral Malodor

Brief summary

The objective of this study is to evaluate the safety of the concentrated mouthwash prototypes, and to evaluate the efficacy of the concentrated mouthwash prototypes in the control of oral malodor compared to a comparator mouthwash and a negative control.

Interventions

OTHERBrush / Espresso Mild Prototype

Subjects will brush and rinse with their assigned mouthwash twice daily.

OTHERBrush / Espresso Intense Prototype

Subjects will brush and rinse with their assigned mouthwash twice daily.

OTHERBrush / Fresh Breath Oral Rinse

Subjects will brush and rinse with their assigned mouthwash twice daily.

OTHERBrush / Hydroalcohol

Subjects will brush and rinse with their assigned mouthwash twice daily.

Sponsors

Johnson & Johnson Consumer and Personal Products Worldwide
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Investigator)

Masking description

Examiner-blind

Eligibility

Sex/Gender
ALL
Age
18 Years to 99 Years
Healthy volunteers
Yes

Inclusion criteria

1. Able to comprehend and follow the requirements and restrictions of the clinical trial (including willingness to use the assigned study products per instructions, availability on scheduled visit dates and likeliness of completing the clinical trial) based upon research site personnel's assessment; 2. Evidence of a personally signed and dated informed consent document indicating the subject (or legally acceptable representative) has been informed of all pertinent aspects of the trial; 3. Able to read and understand the local language (subject is capable of reading the documents); 4. Adequate oral hygiene (i.e., brush teeth daily and exhibit no signs of oral neglect); 5. Adults, 18 years of age and older, in good general and oral health without any known allergy to commercial dental products or cosmetics; 6. Negative pregnancy urine tests (females of child-bearing potential only); * For females: Postmenopausal state (i.e. at least 1 year without menses without an alternative medical condition prior to the first study IP administration) or premenopausal/perimenopausal state with an effective means of contraception. * For males: No pregnant or lactating spouse or partner at screening and willingness to utilize an acceptable form of birth control with spouse or any potential partner during the study and for 30 days thereafter. 7. Females of childbearing potential must be using a medically acceptable method of birth control for at least one month prior to Visit 1 and agree to continue using this method during their participation in the clinical trial. Medically acceptable forms of birth control that may be used by the subject and/or his/her partner include: * Double barrier method (condoms, diaphragm or cervical cap with spermicide), * Hormonal prescription contraceptives (i.e., oral, injectable, implanted, patch or vaginal ring hormone therapy) * Intrauterine device (IUD) * Surgical sterilization (e.g., vasectomy that has been confirmed effective by sperm count check, tubal ligation, hysterectomy and/or bilateral oophorectomy) * Abstinence 8. A minimum of 16 uncrowned teeth; 9. At Screening (Visit 1) and before brushing with the assigned study product at Baseline (Visit 2), subjects must provide 2 samples of mouth air, which must have a mean hydrogen sulfide concentration greater than 200ppb. At screening and baseline (pre-brushing), the two samples of mouth air must have a ≤ 500ppb difference in hydrogen sulfide values; 10. At Baseline (Visit 2), before brushing with assigned dentifrice, subjects must provide a breath sample with a mean organoleptic score ≥3.5 across judges; 11. Absence of significant oral soft tissue pathology, periodontitis and active dental caries, based on a visual examination and at the discretion of the Investigator; and 12. Absence of partial dentures, dentures, orthodontic bands, fixed retainers, removable orthodontic appliances.

Exclusion criteria

1. Diagnosed with Xerostomia; 2. Suspected alcohol or substance abuse at the discretion of the Investigator (e.g., amphetamines, benzodiazepines, cocaine, marijuana, opiates); 3. Known sensitivity, allergy or contraindications to any investigational product ingredient, oral care products and auxiliary supplies provided for the study; 4. Self-reported smokeless tobacco user including snuff, chewing tobacco, vaping and e-cigarette usage; 5. Females who are pregnant, planning to become pregnant or breastfeeding during the study; 6. Subjects who were previously screened and determined to be ineligible for the study (unless subject previously screen failed for the OralChroma GC and/or organoleptic criteria; 7. Participation in any clinical study investigation within 30 days of Screening visit (Visit 1); 8. Planned surgery during the trial period, 6 months prior to clinic visit 1 or 30 days after the end of study period; 9. Has a compromised immune system; 10. Has any acute or chronic, medical or psychiatric conditions) that may increase the risk associated with study participation or investigational product administration or may interfere with the interpretation of study results and, in the judgement of the medically qualified investigator, would make the subject inappropriate for entry in this study; 11. Significant, unstable or uncontrolled medical condition which may interfere with subject's participation in the study, at the discretion of the Investigator; and 12. Subjects who are related to those persons involved directly or indirectly with the conduct of this study (i.e., principal Investigator, sub-investigators, study coordinators, other site personnel, employees of Johnson & Johnson (J&J) subsidiaries, contractors of J&J, and the families of each).

Design outcomes

Primary

MeasureTime frameDescription
Mean malodor intensity assessed at 60 minutes after product useAfter 60 minutes of product useMean malodor intensity will be independently assessed by three odor trained judges 60 minutes after product use on Day 0 using the following scale: 0 = No appreciable odor, 1 = Barely noticeable odor, 2 = Slight but clearly noticeable odor, 3 = Moderate odor, 4 = Strong odor, 5 = Extremely foul odor
Mean malodor intensity assessed at 120 minutes after product useAfter 120 minutes of product useMean malodor intensity will be independently assessed by three odor trained judges 120 minutes after product use on Day 0 using the following scale: 0 = No appreciable odor, 1 = Barely noticeable odor, 2 = Slight but clearly noticeable odor, 3 = Moderate odor, 4 = Strong odor, 5 = Extremely foul odor
Mean malodor intensity assessed at 180 minutes after product useAfter 180 minutes of product useMean malodor intensity will be independently assessed by three odor trained judges 180 minutes after product use on Day 0 using the following scale: 0 = No appreciable odor, 1 = Barely noticeable odor, 2 = Slight but clearly noticeable odor, 3 = Moderate odor, 4 = Strong odor, 5 = Extremely foul odor
Mean malodor intensity assessed at 240 minutes after product useAfter 240 minutes of product useMean malodor intensity will be independently assessed by three odor trained judges 240 minutes after product use on Day 0 using the following scale: 0 = No appreciable odor, 1 = Barely noticeable odor, 2 = Slight but clearly noticeable odor, 3 = Moderate odor, 4 = Strong odor, 5 = Extremely foul odor
Mean malodor intensity assessed at 12 hours after product use on Day 7After 12 hours of product use on Day 7Mean malodor intensity will be independently assessed by three odor trained judges 12 hours after product use on Day 7 using the following scale: 0 = No appreciable odor, 1 = Barely noticeable odor, 2 = Slight but clearly noticeable odor, 3 = Moderate odor, 4 = Strong odor, 5 = Extremely foul odor
Mean malodor intensity assessed at 12 hours after product use on Day 21After 12 hours of product use on Day 21Mean malodor intensity will be independently assessed by three odor trained judges 12 hours after product use on Day 21 using the following scale: 0 = No appreciable odor, 1 = Barely noticeable odor, 2 = Slight but clearly noticeable odor, 3 = Moderate odor, 4 = Strong odor, 5 = Extremely foul odor

Secondary

MeasureTime frameDescription
Hydrogen sulfide concentration assessed at 60 minutes after product use on Day 0After 60 minutes of product use on Day 0Two mouth air sample will be evaluated 60 minutes after product use on Day 0 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the hydrogen sulfide concentration in the breath in the range of 50- 2400ppb.
Hydrogen sulfide concentration assessed at 120 minutes after product use on Day 0After 120 minutes of product use on Day 0Two mouth air sample will be evaluated 120 minutes after product use on Day 0 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the hydrogen sulfide concentration in the breath in the range of 50- 2400ppb.
Hydrogen sulfide concentration assessed at 180 minutes after product use on Day 0After 180 minutes of product use on Day 0Two mouth air sample will be evaluated 180 minutes after product use on Day 0 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the hydrogen sulfide concentration in the breath in the range of 50- 2400ppb.
Hydrogen sulfide concentration assessed at 240 minutes after product use on Day 0After 240 minutes of product use on Day 0Two mouth air sample will be evaluated 240 minutes after product use on Day 0 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the hydrogen sulfide concentration in the breath in the range of 50- 2400ppb.
Hydrogen sulfide concentration assessed at 12 hours after product use on Day 7After 12 hours of product use on Day 7Two mouth air sample will be evaluated 12 hours after product use on Day 7 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the hydrogen sulfide concentration in the breath in the range of 50- 2400ppb.
Hydrogen sulfide concentration assessed at 12 hours after product use on Day 21After 12 hours of product use on Day 21Two mouth air sample will be evaluated 12 hours after product use on Day 21 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the hydrogen sulfide concentration in the breath in the range of 50- 2400ppb.
Methyl mercaptan concentration assessed at 60 minutes after product use on Day 0After 60 minutes of product use on Day 0Two mouth air sample will be evaluated 60 minutes after product use on Day 0 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the methyl mercaptan concentration in the breath in the range of 50- 2400ppb.
Methyl mercaptan concentration assessed at 120 minutes after product use on Day 0After 120 minutes of product use on Day 0Two mouth air sample will be evaluated 120 minutes after product use on Day 0 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the methyl mercaptan concentration in the breath in the range of 50- 2400ppb.
Methyl mercaptan concentration assessed at 180 minutes after product use on Day 0After 180 minutes of product use on Day 0Two mouth air sample will be evaluated 180 minutes after product use on Day 0 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the methyl mercaptan concentration in the breath in the range of 50- 2400ppb.
Total volatile sulfur compounds (VSC) concentration assessed at 60 minutes after product use on Day 0After 60 minutes of product useTwo mouth air sample will be evaluated 60 minutes after product use on Day 0 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the total VSC concentration in breath (hydrogen sulfide, methyl mercaptan, and methyl sulfide) in the range of 50- 2400ppb.
Methyl mercaptan concentration assessed at 12 hours after product use on Day 7After 12 hours of product use on Day 7Two mouth air sample will be evaluated 12 hours after product use on Day 7 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the methyl mercaptan concentration in the breath in the range of 50- 2400ppb.
Methyl mercaptan concentration assessed at 12 hours after product use on Day 21After 12 hours of product use on Day 21Two mouth air sample will be evaluated 12 hours after product use on Day 21 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the methyl mercaptan concentration in the breath in the range of 50- 2400ppb.
Methyl sulfide concentration assessed at 60 minutes after product use on Day 0After 60 minutes of product use on Day 0Two mouth air sample will be evaluated 60 minutes after product use on Day 0 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the methyl mercaptan concentration in the breath in the range of 50- 2400ppb.
Methyl sulfide concentration assessed at 120 minutes after product use on Day 0After 120 minutes of product use on Day 0Two mouth air sample will be evaluated 120 minutes after product use on Day 0 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the methyl mercaptan concentration in the breath in the range of 50- 2400ppb.
Methyl sulfide concentration assessed at 180 minutes after product use on Day 0After 180 minutes of product use on Day 0Two mouth air sample will be evaluated 180 minutes after product use on Day 0 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the methyl mercaptan concentration in the breath in the range of 50- 2400ppb.
Methyl sulfide concentration assessed at 240 minutes after product use on Day 0After 240 minutes of product use on Day 0Two mouth air sample will be evaluated 240 minutes after product use on Day 0 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the methyl mercaptan concentration in the breath in the range of 50- 2400ppb.
Methyl sulfide concentration assessed at 12 hours after product use on Day 7After 12 hours of product use on Day 7Two mouth air sample will be evaluated 12 hours after product use on Day 7 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the methyl mercaptan concentration in the breath in the range of 50- 2400ppb.
Methyl sulfide concentration assessed at 12 hours after product use on Day 21After 12 hours of product use on Day 21Two mouth air sample will be evaluated 12 hours after product use on Day 21 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the methyl mercaptan concentration in the breath in the range of 50- 2400ppb.
Methyl mercaptan concentration assessed at 240 minutes after product use on Day 0After 240 minutes of product use on Day 0Two mouth air sample will be evaluated 240 minutes after product use on Day 0 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the methyl mercaptan concentration in the breath in the range of 50- 2400ppb.
Total volatile sulfur compounds (VSC) concentration assessed at 120 minutes after product use on Day 0After 120 minutes of product useTwo mouth air sample will be evaluated 120 minutes after product use on Day 0 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the total VSC concentration in breath (hydrogen sulfide, methyl mercaptan, and methyl sulfide) in the range of 50- 2400ppb.
Total volatile sulfur compounds (VSC) concentration assessed at 180 minutes after product use on Day 0After 180 minutes of product useTwo mouth air sample will be evaluated 180 minutes after product use on Day 0 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the total VSC concentration in breath (hydrogen sulfide, methyl mercaptan, and methyl sulfide) in the range of 50- 2400ppb.
Total volatile sulfur compounds (VSC) concentration assessed at 240 minutes after product use on Day 0After 240 minutes of product useTwo mouth air sample will be evaluated 240 minutes after product use on Day 0 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the total VSC concentration in breath (hydrogen sulfide, methyl mercaptan, and methyl sulfide) in the range of 50- 2400ppb.
Total volatile sulfur compounds (VSC) concentration assessed at 12 hours after product use on Day 7After 12 hours of product use on Day 7Two mouth air sample will be evaluated 12 hours after product use on Day 7 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the total VSC concentration in breath (hydrogen sulfide, methyl mercaptan, and methyl sulfide) in the range of 50- 2400ppb.
Total volatile sulfur compounds (VSC) concentration assessed at 12 hours after product use on Day 21After 12 hours of product use on Day 21Two mouth air sample will be evaluated 12 hours after product use on Day 21 using the Oral Chroma Halitosis Measuring instrument, a portable gas chromatograph with a highly sensitive semiconductor gas detector that will determine the total VSC concentration in breath (hydrogen sulfide, methyl mercaptan, and methyl sulfide) in the range of 50- 2400ppb.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026