Neonatal Disease
Conditions
Keywords
neonatologist performed lung ultrasound, extubation failure, neonates, consolidation
Brief summary
The objective of the study is to evaluate the role of neonatologist-performed lung ultrasound (NPLUS) after weaning from invasive mechanical ventilation and extubation. Our aim is to study the diagnostic accuracy of NPLUS and investigate whether LUS leads to earlier actions before clinical deterioration and hence prevents extubation failure.
Detailed description
In the past few years, lung ultrasound has been established as a tool to dynamically assess the lungs in various clinical conditions. Standardized protocols have been compiled to allow for an easy and fast evaluation. The point-of-care ultrasound (POCUS) is easily accessible and allows the clinician a readily available bed-side evaluation. Although invasive mechanical ventilation displays a lifesaving strategy in neonatal intensive care, it is associated with numerous long-term complications especially in preterm infants. Despite a shift to lung-protective ventilation, time on mechanical ventilatory support should be kept as short as possible, considering timely weaning and switch to a non-invasive ventilation. Estimating the right time for discontinuation of invasive mechanical ventilation remains challenging and is influenced by several parameters. Extubation failure can be associated with respiratory failure following exhaustion on non-invasive ventilatory support. Collapse of alveolar units lead to hypo-aerated areas. Small airway size, obstruction due to secretion and muscular weakness predispose to the development of atelectasis in neonates. Atelectasis occurring post extubation are a frequent cause of extubation failure. Lung consolidations can be sonographically detected. A sensitivity of 100% for the detection of neonatal pulmonary atelectasis has been described. In recent studies Lung Ultrasound Severity Score (LUSS) has been shown to be an independent predictor of successful extubation in mechanically ventilated preterm infants. However, once extubated, only limited data is available if extubation failure later in the process can be predicted. Lung aeration decreased after extubation to spontaneous breathing. Early standardized evaluation of the lung via lung ultrasound can deliver important information on aeration of the lungs and whether action may be required. Using a standardized protocol (lung ultrasound score, LUS) on certain timepoints after extubation can lead to early detection of loss of aeration. Timely intervention with e.g., temporary PEEP increase for alveolar recruitment on non-invasive ventilatory support, positioning of the patient prior to clinical deterioration can impede the need of a reintubation and invasive mechanical ventilatory support.
Interventions
NPLUS is conducted with an ultrasound scanner using a high-frequency (12-15 MHz) linear transducer probe (scanning depth approximately 4-5 cm). The neonate is placed in a supine position. The anterior, lateral and posterior chest areas are scanned using the presets lung or small parts. Landmarks are the anterior and posterior axillary line (longitudinal) on each hemithorax. A sequential scan from right to left, anterior to posterior is performed. (6 lung areas). In the study NPLUS is performed to quantify the lung ultrasound score at time points T0, T1 and T2. Sequences of 3-5 seconds are saved and assessed according to the lung ultrasound score adapted by Rodriguez-Fanjul et al. (0- to 3 point score for each area, resulting in a total score ranging from 0 to 18). To ensure inter-observer reliability the anonymous video sequences are then rated by two independent neonatologists.
Sponsors
Study design
Eligibility
Inclusion criteria
* All preterm and full-term neonates receiving invasive mechanical ventilation at the Division of Neonatology of the Medical University of Graz AND * Written informed consent was obtained from parents prior to extubation
Exclusion criteria
none
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| Reintubation rate (within 72 hours after extubation) | within 72 hours after extubation |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Respiratory settings- FiO2 | within 72 hours after extubation | FiO2 (fraction of inspired oxygen) during 72 hours after extubation |
| Respiratory settings- PEEP | within 72 hours after extubation | PEEP (Positive EndExpiratory Pressure) during 72 hours after extubation |
| SpO2/FiO2 ratio | every hour during 72 hours after extubation | Ratio of arterial oxygen saturation and fraction of inspired oxygen |
| pH from capillary blood gas analysis | within 72 hours after extubation | pH routinely obtained capillary blood gas analysis at certain time points within 72 hours after extubation |
| Carbon dioxide partial pressure (pCO2) | within 72 hours after extubation | pCO2 Routinely obtained capillary blood gas analysis at certain time points within 72 hours after extubation |
| Mode of respiratory support | within 72 hours after extubation | NCPAP, DUOPAP or BILEVEL during 72 hours after extubation |
| Number of lung imaging | within 72 hours after extubation | Number of chest X-rays and NPLUS within 72 hours after extubation |
| Number of lung imaging based interventions | within 72 hours after extubation | Number and time points of chest X-ray or NPLUS based interventions |
| Recruitment maneuvers | within 72 hours after extubation | Number and time points of recruitment maneuvers (PEEP increase, positioning) |
| Time to detect consolidations | within 72 hours after extubation | Time to detect impairment of lung aeration (consolidations) |
| Lung ultrasound scores (LUS) | up to 24 hours after extubation | LUS at time point T0 (prior to extubation), T1 (2-4 hours post extubation) and time point T2 (16-24 h post extubation) |
| Base Excess (BE) | within 72 hours after extubation | BE routinely obtained capillary blood gas analysis at certain time points within 72 hours after extubation |
Countries
Austria