Skip to content

Thumb Hemi-Arthroplasty With Natural Kinematics; a Prospective Multicenter Study to Confirm the Safety and Efficacy of the InDx Implant

Thumb Hemi-Arthroplasty With Natural Kinematics; a Prospective Multicenter Study to Confirm the Safety and Efficacy of the InDx Implant

Status
Terminated
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06467760
Acronym
THANKS PRO
Enrollment
14
Registered
2024-06-21
Start date
2025-03-19
Completion date
2026-05-20
Last updated
2026-07-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

CMC Joint Arthritis

Brief summary

Prospective, multicentric non-comparative confirmatory study to evaluate the safety and performance of the InDx CMC implant for the treatment of CMC joint arthritis.

Interventions

DEVICEInDx CMC Implant

The InDx CMC Implant is a hemiarthroplasty device for the CMC joint which consists of a unified assembly of three components: metacarpal stem, polyethylene liner, and articulating head. Because the device functions as a hemiarthroplasty, it does not link or constrain the CMC joint

Sponsors

Loci Orthopaedics
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* The patient is at least 18 years of age; * The patient has a confirmed Grade I-III osteoarthritis of the CMC joint on clinical examination and X-ray; * The patient is eligible for surgical treatment of CMC I arthrosis in the opinion of the investigator. * The patient agrees to abstain from enrolment in any other clinical trials that will conflict or interfere with the interpretation of the results of this study, in the opinion of the Investigator, for the duration of the study; * The patient is able to understand the aims and objectives of the trial and is willing to consent; * The patient is willing and able to return for all study-related follow-up procedures; * If the patient is female, is either using contraception or is postmenopausal, or male partner is using contraception

Exclusion criteria

* The patient is suffering from Rheumatoid arthritis in the index hand; * The patient is suffering from Grade IV osteoarthritis of the CMC joint; * The patient is suffering post-traumatic arthritis of the CMC joint in the index hand; * The patient is a pregnant/lactating female (tested as per institutional requirements); * Active or latent infection, or sepsis; * Insufficient quantity or quality of bone and/or soft tissue in the index hand; * Metal or polymer material sensitivity; * Muscular imbalance, peripheral vascular disease that prohibits adequate healing, or a poor soft-tissue envelope in the surgical field, absence of musculoligamentous supporting structures, or peripheral neuropathy; * Patient with previous thumb surgery in the index hand * In the opinion of the investigator, any medical condition that makes the subject unsuitable for inclusion in the study, including, but not limited to * Patients with a diagnosis of concomitant injury that may interfere with healing * Patients with clinically significant renal, hepatic, cardiac, endocrine, hematologic, autoimmune, or any systemic disease or systemic infection that may make interpretation of the results difficult * Patients who have undergone systemic administration within 30 days prior to implantation of any type of corticosteroid, antineoplastic, immunostimulating, or immunosuppressive agents * Comorbidity that reduces life expectancy to less than 36 months

Design outcomes

Primary

MeasureTime frameDescription
Device Safety6 MonthsDetermine the incidence of device failure, encompassing mechanical malfunction, structural compromise, loss of functionality due to device failure, or any deviation from the device's intended medical purpose. This will involve monitoring for adverse events requiring total revision surgery, or premature termination of device usage due to device failure.
Performance12 MonthsMeasure the improvement in hand and wrist functionality using the Disabilities of the Arm, Shoulder, and Hand (DASH) score.

Countries

Belgium, Netherlands

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Jul 23, 2026