Skip to content

Accuracy of LAA Occluder Size Selection: CT vs. DSA During Combined AF Ablation and LAA Occlusion

The Accuracy of Left Atrial Appendage Occluder Size Selection Between Preoperative CT and Intraoperative DSA Evaluation During a Combined Atrial Fibrillation Ablation and Left Atrial Appendage Occlusion Procedure

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06455644
Enrollment
238
Registered
2024-06-12
Start date
2024-07-31
Completion date
2031-07-31
Last updated
2024-06-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Arrhythmias, Cardiac, Atrial Fibrillation, Cardiovascular Diseases, Heart Diseases

Keywords

Left atrial appendage closure, Atrial fibrillation, Pacifier-like occluder, Stroke prevention

Brief summary

This study is a prospective, multi-center, randomized controlled trial. The subjects are patients scheduled to undergo a combined procedure of atrial fibrillation (AF) ablation and left atrial appendage (LAA) occlusion. After signing the informed consent form, the subjects will be randomly assigned to either the cardiac Computed Tomography (CT) group or the Digital Subtraction Angiography (DSA) group. The operator will select the appropriate LAA occluder size for implantation based on different measurement methods. All subjects will undergo clinical follow-up before discharge and at 3 months postoperatively, as well as telephone follow-up 1-5 years after the surgery.

Interventions

After completing the AF ablation, select the appropriate LAA occluder based on preoperative CT measurements for implantation.

OTHERDSA group

After completing the AF ablation, select the appropriate LAA occluder based on intraoperative DSA measurements for implantation.

Sponsors

First Affiliated Hospital of Shantou University Medical College
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Age ≥ 18 years; 2. Patients with non-valvular atrial fibrillation scheduled to undergo atrial fibrillation ablation and percutaneous left atrial appendage occlusion; 3. Able to understand the purpose of the trial, willing to participate in the study, and the subject or their legal representative has signed the informed consent form, and is willing to complete the follow-up according to the protocol requirements.

Exclusion criteria

1. Allergy to contrast agents or other conditions that preclude cardiac CT or DSA imaging; 2. Absence of clear images for measuring the diameter of the LAA in all layers of the CT scan; 3. Imaging indicates the presence of thrombus in the left atrium or LAA; 4. Patients with valvular AF (mechanical valve replacement or moderate to severe mitral stenosis combined with AF); 5. LAA depth \< 15 mm, or LAA anchor zone diameter \< 10 mm or \> 33 mm; 6. Female patients of childbearing age planning to become pregnant during the follow-up period required by this study; 7. Currently participating in another clinical trial of drugs or medical devices and has not yet completed the primary endpoints of that study, which may confound the results of this study or affect the participant's compliance with the follow-up; 8. Other conditions that the investigator deems make the participant unsuitable for this study.

Design outcomes

Primary

MeasureTime frameDescription
Accuracy of LAA occluder size selectionDuring procedureAccuracy is defined as: the occluder's anchor disc seats beyond the circumflex artery, the compression of the anchor disc after release is 3-6 mm, peri-device leak is ≤ 3 mm, and the occluder remains stable during the tug test.

Secondary

MeasureTime frameDescription
Procedure successDuring procedureTechnical success of the LAA occlusion procedure without serious procedure-related complications
Peri-device leak at 3 months post-procedure3 monthsProportion of peri-device leak at the occluder evaluated by TEE or CT
Procedure-related timesDuring procedureTotal procedure time, AF ablation time, and LAA occlusion time
Incidence of major adverse events (MAE) related to the device or procedure within 3 months post-procedure3 monthsMAE is defined as unexplained death or any device or procedure-related complications, including but not limited to death, stroke, or transient ischemic attack (TIA), serious pericardial effusion/pericardial tamponade requiring pericardiocentesis or surgery, device embolization, life-threatening or severe bleeding events, and severe vascular access complications

Countries

China

Contacts

Primary ContactZhongbo Xiao, MD
307523577@qq.com

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026