Leadless Pacemaker, Same-day Discharge
Conditions
Brief summary
Leadless pacemakers (LP) are associated with a lower risk of revision compared with transvenous pacemakers. However, LPs implantation is associated with a 0.6% risk of complication at the femoral vein puncture site (e.g. arteriovenous fistula, haemorrhage, pseudoaneurysm, etc.). As a consequence, the need for prolonged in-hospital monitoring after LP implantation though the right femoral (RF)vein is a barrier to same-day discharge. Recently, right internal jugular (RIJ) vein access has emerged an alternative to right RF vein access for LP implantation (with a regulatory approval for MEDTRONIC Micra LP). The aims of this registry are the following : * evaluate the feasibility of RIJ access for LP implantation; * confirm the acute and chronic safety of RIJ access for LP implantation; * compare RIJ to RF (historical cohort) vein access regarding procedural characteristics and outcomes; * evaluate the feasibility of same-day discharge avec LP implantation through the RIJ vein.
Interventions
Leadless pacemaker implantation through right internal jugular vein
Sponsors
Study design
Eligibility
Inclusion criteria
* Indication of pacemaker implantation * Eligible to leadless pacemaker
Exclusion criteria
* Contraindication to right internal jugular vein access * Age \< 18 year-old * Patient already included in a clinical study
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Rate of effective of jugular access | [0 - 1 Month] | Feasibility of jugular access for leadless pacemaker implantation, defined as the percentage of patients with a successful leadless pacemaker implantation through the jugular vein. |
| Rate of effective same-day discharge | [0 - 1 Month] | Feasibility of same-day discharge after implantation of a leadless pacemaker through the jugular vein, defined as a successful same-day discharge with no readmission during the first postoperative month. |
| Incidence of major cardiovascular event | [0 - 12 Month] | Incidence of major complications related to the implantation of a leadless through the jugular vein: * pericardial complications (effusion, tamponade, pericardiocentesis) * jugular venous complications (bleeding, hematoma, arteriovenous fistula, vascular surgery) * carotid artery complications (bleeding, transient ischemic attack or stroke, vascular surgery) * pacemaker malfunction * infection * cardiac rhythm complications (atrioventricular block, ventricular fibrillation ou tachycardia, cardiac arrest) * air embolism |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Description of procedural characteristics | During implantation procedure | Procedural characteristics of leadless pacemaker implantation through the jugular vein (duration, position, number of attempts, ...). |
Countries
France