Skip to content

OB-GYN Clinical Validation Study

ECHO-007 OB-GYN Clinical Validation Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06449872
Enrollment
44
Registered
2024-06-10
Start date
2023-10-24
Completion date
2024-04-30
Last updated
2024-06-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

GYN Disorders, Obstetric Complication

Brief summary

This is a single-site study evaluating obstetrics and gynecology exam imaging quality by expert users.

Detailed description

Six healthcare professionals with training and experience in Obstetrics and Gynecology ultrasound qualitatively assessed the image quality of the Kosmos Diagnostic Ultrasound System compared to the benchmark Mindray M9 Ultrasound System. Five sonographers were required to complete each scanning cohort of at least three gravid and three non-gravid participants. A sixth sonographer was added to the study to accommodate a scheduling conflict and provided additional image quality data outside of the five completed cohorts. The following views/structures were assessed for image quality: Gynecology participants: * Uterus * Ovaries * Endometrial cavity * Cervix • Obstetrics participants in their 1st trimester: * General image quality of the fetus * Ability to visualize the crown rump length * Visualization of gestational sac * Visualization of yolk sac if present • Obstetrics and participants in their 2nd trimester: * General image quality of the fetal structures * Visualization of the amniotic fluid * Visualization of the placenta * Cardiac motion in 2D and M-mode with heart rate Obstetrics and participants in their 3rd trimester: * General image quality of the fetal structures * Visualization of the amniotic fluid * Visualization of the placenta * Visualization of the maternal cervix * Cardiac motion in 2D and M-mode with heart rate * 3 vessel umbilical cord in 2D and Color Doppler The sonographers captured all views/structures on the Mindray M9 Ultrasound System, then switched over to the Kosmos Diagnostic Ultrasound System to capture the same views/structures. Once all views/structures were captured on both ultrasound systems, the healthcare professionals reviewed the images in parallel on each system, then provided a comparison score for Kosmos between 1 and 7.

Interventions

DEVICEObstetrics and Gynecology clinical applications for ultrasound diagnostic systems

Up to 5 healthcare professionals trained and experienced in Obstetrics and Gynaecology ultrasound qualitatively assessed the diagnostic image quality of the Kosmos Diagnostic Ultrasound System against the benchmark Mindray M9 Ultrasound System.

Sponsors

EchoNous Inc.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 40 Years
Healthy volunteers
Yes

Inclusion criteria

1. Persons able to: 1. Read and sign an English consent form. 2. Read and complete an English demographic and general health survey. 3. Give consent for participation. 4. Able and willing to comply with study requirements. 2. Those aged 18 years through 40 years, healthy, particularly in respect to their pregnancy. 3. Pregnant individuals who have received a previous ultrasound exam by their physician.

Exclusion criteria

1. Children (minors) under 18 years old. 2. Adults over 40 years old. 3. Those who cannot or refuse to sign their consent. 4. Those who cannot provide informed consent. 5. Vulnerable populations, i.e., individuals whose willingness to participate in the study could be unduly influenced by the expectation of medical benefits associated with participation. 6. Vulnerable populations, i.e., individuals whose willingness to participate in the study could be unduly influenced by parents, employer or monetary benefit. 7. Pregnant individuals who have not received a previous ultrasound exam by their physician. 8. Individuals who have had a hysterectomy, oophorectomy, and trachelectomy.

Design outcomes

Primary

MeasureTime frameDescription
Average Ultrasound Image Quality ScoreThrough study completion, up to 1 monthQualitative image assessment of required views/structures generated with Kosmos Diagnostic Ultrasound System versus a cart-based ultrasound system.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026