Skip to content

Arterial Blood Pressure and Cardiac Arrest

Arterial Blood Pressure and Cardiac Arrest

Status
Withdrawn
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06443567
Acronym
ABaCAS
Enrollment
0
Registered
2024-06-05
Start date
2024-09-30
Completion date
2025-06-30
Last updated
2025-09-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cardiac Arrest

Keywords

impedance threshold device, blood pressure, cardiac arrest

Brief summary

To describe and measure diastolic and systolic femoral arterial pressure during medical cardiac arrest. To define baseline measures. To describe and measure arterial blood pressure after placement of an ITD device. To observe the diastolic pressure immediately prior to return of spontaneous circulation. To quantify and describe the effects of intravenous adrenaline on arterial blood pressure in cardiac arrest.

Detailed description

Cardiac arrest is a complex disorder whose outcome is reliant on a huge number of factors. Moreover, many interventions are time critical, therefore an intervention that may be lifesaving if given early, may have no benefit if instigated further in the disease course. For these reasons' studies involving cardiac arrest are incredibly difficult to carry out and interpret. Many of the interventions carried out during cardiac arrest are aimed at improving blood pressure and thereby increasing the amount of blood and oxygen delivered to the myocardium in the hopes of achieving a return of spontaneous circulation (ROSC). However current data on what a 'normal' blood pressure, based largely upon non-invasive measurement, during cardiac arrest is severely limited, making comparison and evaluation of interventions extremely difficult. This provides the basis for this study in order to prospectively collate and describe data from invasive blood pressure monitoring during adult, medical cardiac arrest in the pre-hospital environment. 3\. Research Question/Aim(s) To measure and describe femoral arterial pressure during cardiac arrest with mechanical CPR by a LUCAS device. 3.1 Objectives Primary objective To quantify and describe baseline arterial systolic blood pressure as measured by an invasive femoral line in adult patients suffering medical cardiac arrest in the pre-hospital setting. This will be defined as a line of best fit for systolic blood pressure superimposed on the arterial trace during a 3 minute period. Secondary Objectives * To quantify and describe baseline arterial diastolic blood pressure as measured by an invasive femoral line in adult patients suffering medical cardiac arrest in the pre-hospital setting. This will be defined as a line of best fit for diastolic blood pressure superimposed on the arterial trace during a 3 minute period. * To quantify and describe arterial blood pressure after the placement of an ITD device over a 3 minute period. * To quantify and describe the effect of intravenous adrenaline on blood pressure as administered in line with ALS guidelines (every 3-5 mins) in adult patients in cardiac arrest. * To document the diastolic blood pressure of those patients that achieve return of spontaneous circulation (ROSC) following out of hospital cardiac arrest.

Interventions

impedance threshold device (ResQPOD, Zoll) applied to airway

Sponsors

North West Ambulance Service nhs foundation trust
CollaboratorUNKNOWN
Manchester University NHS Foundation Trust
Lead SponsorOTHER_GOV

Study design

Observational model
CASE_CONTROL
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adult patients (≥18years) in medical cardiac arrest * Deemed suitable to attempt resuscitation.

Exclusion criteria

* Prisoners * \<18years * Pregnancy * Traumatic cardiac arrest * Arrest caused by hypovolaemia, tension or tamponade as determined by the clinical team on scene * Inability to secure a patent airway.

Design outcomes

Primary

MeasureTime frame
systolic femoral invasive blood pressure3 mins average with CPR by LUCAS device

Secondary

MeasureTime frame
femoral diastolic pressure3 mins average with CPR by LUCAS device
femoral arterial pressure, both systolic and diastolic3 mins average post placement of ICD device

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026