A Point-of-care Electrochemical-based Device for Rapid Detection of Fibrinogen on Type A Aortic Dissection Surgery

A Point-of-care Electrochemical-based Device for Rapid Detection of Fibrinogen on Type A Aortic Dissection Surgery

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06434389
Enrollment
150
Registered
2024-05-30
Start date
2024-06-01
Completion date
2025-10-31
Last updated
2025-05-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hypofibrinogenemia

Brief summary

This study compares the results of the existing fibrinogen concentration monitoring technology to the Electrochemical-based device, a point-of-care and rapid method,using a small amount of extra blood obtained in Type A Aortic Dissection Surgery.

Detailed description

Electrochemical-based device for rapid detection of fibrinogen is a novel POC diagnostic method, which is suitable for operating theatres and emergency rooms. The novel fibrinogen detection based on Gel electrodes combined with immunobiosensing strategies and use magnitude of current to characterize the fibrinogen concentration , which will be a POC assay of fibrinogen detection for critically ill patients. This single-center, prospective, observational pilot study will evaluate the analytical performance as well as compared to conventional Clauss laboratory reference method.

Interventions

DIAGNOSTIC_TESTthe Electrochemical-based device

Electrochemical-based device for rapid detection of fibrinogen is a novel POC diagnostic method, which is suitable for operating theatres and emergency rooms.

Sponsors

Second Affiliated Hospital, School of Medicine, Zhejiang University
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

Part1 Phase I-Laboratory calibration. The electrochemical method was employed to detect the fibrinogen concentration of standard quality control materials with varying concentration gradients, and the corresponding current values were recorded for constructing a standard curve of fibrinogen concentration. Phase II-Assay performance using clinical samples. Subject is 18 years and underwent routine hemostasis analysis. using human biological samples already collected for routine hemostasis analysis, The samples were centrifuged at 2500g for 15 min at room temperature, to obtain PPP (residual platelet count of \<10 × 10\^9/L) and stored at-20℃used for determination by electrochemical method within 2 weeks, Each clinical sample was tested three times Part2 Inclusion Criteria: Subject underwent surgery for acute type A aortic dissection at our hospital, Subject is 18 years, Subject requires routine TEG measurement, Subject use human fibrinogen concentrate during surgery.

Exclusion criteria

Use Extracorporeal Membrane Oxygenation after surgery, inability to obtain written informed consent

Design outcomes

Primary

MeasureTime frame
The fibrinogen concentration values obtained using the Clauss method and electrochemical method were compared1 day

Secondary

MeasureTime frame
the time of the two detection methods1 day

Countries

China

Contacts

Primary ContactFengjiang ZHANG
zrzfj@zju.edu.cn+8613858007629

Outcome results

None listed