Skip to content

Clinical Validation of BACTEC™ Plus Aerobic/F Culture Vials Compared With Equivalent Product

Clinical Validation of BACTEC™ Plus Aerobic/F Culture Vials Compared With Equivalent Product

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06426121
Enrollment
394
Registered
2024-05-23
Start date
2024-06-26
Completion date
2025-10-23
Last updated
2025-11-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Sepsis

Brief summary

This study is a multi-center, randomized clinical validation. Subjects should be fully informed of this protocol and related risks, and can only be enrolled into this study after signing the informed consent form. Blood collection of the subjects at the same puncture point at a single site will be injected into the test vial and the control vial respectively, and the vials will be transferred to the BACTEC system for culture and the results will be observed. After the BACTEC system incubation completion, the vials will be subcultured. Strains grown on plates will be identified using appropriate methods and, if possible, at the species level.

Interventions

DIAGNOSTIC_TESTtest Aerobic/F Culture Vials

an additional blood sample will be collected compared to clinical routine of blood culture, inoculated into the test culture vial, and compared with the blood culture results of the control vial collected from the same site and the same puncture point

DIAGNOSTIC_TESTcontrol Aerobic/F Culture Vials

according to the clinical routine of blood culture, this blood sample should be collected and inoculated into the control vial, and its culture result will be collected

Sponsors

Becton, Dickinson and Company
Lead SponsorINDUSTRY

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Subject is willing to provide written informed consent to sponsor. * Blood specimens * Patients with suspected blood infection that have one or more of the following characteristics : a) Body temperature \> 38°C or body temperature \<36°C; b) chills; c) increased peripheral blood leukocyte count (count \> 10.0×109/L, especially if there is a left shift) or decrease (count \< 3.0×109/L); d) Respiratory rate \> 20 beats/min or arterial partial pressure of carbon dioxide (PaCO2) \<32mmHg; e) Heart rate\> 90 beats/min; f) mucocutaneous hemorrhage; g) coma; h) Multi-organ dysfunction; i) decreased blood pressure; j) Elevated inflammatory response parameters such as C-reactive protein or hypersensitive C-reactive protein, procalcitonin (PCT), 1,3-β-D-glucan (G test), etc.

Exclusion criteria

* Subjects have been enrolled in this study and samples have been collected * Patients with severe and very severe anemia (last hemoglobin \<60g/L within seven days) * Females with known pregnancy

Design outcomes

Primary

MeasureTime frameDescription
consistency rate8 daysThe consistency rate of the test vials and the control vials BACTEC™ system test results, including the overall consistency rate, positive consistency rate, and negative consistency rate

Countries

China

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026