Skip to content

First in Human Study for the Assessment of Safety and Initial Performance of the EAS1 System

Snipe Medical First In Human Study

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06423690
Enrollment
15
Registered
2024-05-21
Start date
2024-11-01
Completion date
2025-07-15
Last updated
2024-12-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Lung Cancer

Brief summary

A Prospective, open label, multi center, single arm, First in Human study to assess the safety and initial performance of EAS1 system for Irreversible Electroporation (IRE) ablation of lung cancer in subjects eligible for tumor resection

Interventions

DEVICEEAS1 System

tumor ablation system in IRE method

Sponsors

Snipe Medical
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Adult male and female subjects (age ≥18 years at the date of informed consent signature) * Subject is capable and willing to provide an informed consent * Subjects with a known diagnosis of lung cancer at cT1a-T1c, cN0 stages * At least one pulmonary tumor (primary or metastasis) ≤ 30 mm in maximal diameter, as confirmed by the latest standard of care imaging (CT/MRI), performed preferably up to 30 days prior to screening * Subjects who are scheduled or deemed eligible by a thoracic surgeon for lung tumor resection * Subject is able and willing to comply with the study procedures and visits * There is ≥ 5mm of nodule-free lung parenchyma between target nodule and pleura or fissure, as confirmed by the latest standard of care imaging (CT/MRI), performed preferably up to 30 days prior to screening * ECOG 0-1 * Stable doses of concomitant medications for at least four (4) weeks prior to enrollment

Exclusion criteria

* An inability to provide informed consent * Subjects with contraindication for tumor resection * Subjects with life expectancy \<12 months * Target nodule is abutting main stem bronchus, main pulmonary vasculature, esophagus and/or trachea * Subjects with Forced Expiratory Volume (FEV1) \<50% * Total Lung Capacity (TLC)\< 80% of expected for age * Diffusing Capacity (DCO) \< 60% of expected * Oxygen saturation in free air of \<88%, or requiring more than 2 l/min oxygen to achieve saturation of 92% * PCO2 of ≥ 45mm/Hg * Subjects in exacerbations group E (high risk; ≥2 exacerbations per year or ≥1 requiring hospitalization and any level of symptoms) * Severe emphysema, Bullous Emphysema or chronic obstructive pulmonary disease (COPD) (GOLD III/IV) * Active and/or prolonged lung or bronchi infection, required an antibiotic treatment up to 21 days prior to screening and for more than 10 days of treatment * Known history or current evidence of a significant bronchiectasis * Evidence of lung Bullae the occupies more than one third of the lung intended for ablation * Previous surgery in the lung intended for ablation; thoracic major surgery at the side intended for ablation * Anticoagulation treatment that cannot be discontinued prior to the ablation, or a bleeding diathesis or platelets \<100 )K/µl) * Pregnant or breastfeeding female subjects or female subjects who plan pregnancy during participation in the study * Highly hypoxemic patients, according to investigator's discretion * Subjects with implanted metal or electronic thoracic devices objects (such as pacemaker) that cannot be removed prior to procedure * Subjects with contraindication for bronchoscopy * Participation in any other interventional clinical trial with medication, medical device and/or supplements within 30 days prior to informed consent signature * Any subject who, at the discretion of the investigator, may be jeopardized by study participation

Design outcomes

Primary

MeasureTime frameDescription
Safety of the EAS1 System in Lung Tumor Ablation During Procedure48 hours post procedureAccumulative rate of device related Serious Adverse Events (SAEs) during the ablation and up to 48 hours post ablation

Secondary

MeasureTime frameDescription
Safety of the EAS1 System in Lung Tumor Ablation Throughout Follow Up30 daysRate of device related SAEs during the follow up period
Investigator's Ability to Approach and Ablate the Tumor (Technical Success)30 days\- Technical success, defined as the investigator's ability to access the target tumor and successfully perform the irreversible electroporation, as confirmed by histology analysis

Other

MeasureTime frameDescription
Investigator's Impression of the Treatment (Investigator's Satisfaction)30 daysInvestigator satisfaction, as determined by completing an internal ease-of-use questionnaire following each procedure. The questionnaire consists of 10 questions, each ranging from 1 (not at all) to 5 (very much). Range of total score is 10-50, where the higher the total score, the more satisfied the investigator is from device use
Assessment of Immunological Response Following Ablation30 daysImmunological response, as determined by change from baseline to 30 day FU in immunological blood markers.

Countries

Israel, Spain, United Kingdom

Contacts

Primary ContactEmily Ben Shlomo
emily.benshlomo@clalit.org.il972523212687

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026