Skip to content

Can Needle Size Improve Cancer Detection Rate of Transperineal MRI Target Prostate Biopsy Without Affecting Side Effects?

AOP2780 - Can Needle Size Improve Cancer Detection Rate of Transperineal MRI Target Prostate Biopsy Without Affecting Side Effects?

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06420115
Acronym
TARGET
Enrollment
580
Registered
2024-05-17
Start date
2024-06-01
Completion date
2026-05-30
Last updated
2025-03-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Prostate Cancer Diagnosis

Keywords

pca, needle, 16 gauge, 18 gauge

Brief summary

Differences in terms of diagnostic capability and side effects related to the needle caliber used for prostate biopsy sampling in patients with suspected prostate cancer

Detailed description

To assess whether a larger caliber (16G) prostate biopsy needle increases the diagnostic capability of prostate neoplasia compared to a smaller caliber (18G) needle, while keeping perioperative complications constant.

Interventions

DEVICEdifferent needle size for prostate biopsy

MRI Fusion Transperineal Prostate Biopsy

Sponsors

University Hospital Padova
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Clinical suspicion of prostate cancer (presence of elevated prostatic specific antigen and/or suspicious digital rectal examination); * Presence of at least one suspicious prostate lesion on MRI (Prostate Imaging-Reporting and Data System ≥ 3) according to the Prostate Imaging-Reporting and Data System v2.1 performed before Magnetic Resonance Imaging/transrectal ultrasound fusion biopsy.

Exclusion criteria

* Patients under active surveillance or with a previous diagnosis of prostate neoplasia prior to biopsy. * Previous radiotherapy to the prostate for neoplasia.

Design outcomes

Primary

MeasureTime frameDescription
Total number of random and fusion-target biopsies with presence of prostate cancerWhen histological report availableThe primary outcome measure involves assessing the total number of biopsies, including both random and fusion-targeted approaches, that reveal the presence of prostate cancer.
Number of random and fusion-target biopsies with clinically significant prostate cancer (defined as International Society of Urological Pathology >=2)When histological report availableThe primary outcome measure focuses on the number and the detection rates of random and fusion-target biopsies revealing clinically significant prostate cancer aof clinically significant prostate cancer (defined as ISUP \>=2) between 16-gauge and 18-gauge biopsy needles.

Secondary

MeasureTime frameDescription
Neoplasia/core ratio for each random and fusion-target biopsyWhen histological report availableNeoplasia/core ratio, indicates the ratio of neoplastic tissue to healthy tissue within biopsy cores obtained through both 16 and 18 gauge biopsies for prostate cancer diagnosis. By analyzing this ratio, investivators seek to identify differences in diagnosis across the two different sizes
Intra- and perioperative pain with 18G and 16G needles assessed using visual analog scale (VAS)30 daysThe validated pain questionnaire employed in this study is designed to comprehensively assess the intra- and perioperative pain (following 7 days) experienced by patients undergoing prostate biopsy procedures with 18G and 16G needles. The visual analog scales VAS is a standardized validated questionnaire, a horizontal line, where one end represents 1 - no pain and the other end represents 10 - worst possible pain. Patients are asked to mark on the line the point that best represents the intensity of their pain.
Number of hospitalizations at 30 and 60 days post-procedure60 days from biopsyBy tracking the number of hospitalizations occurring at both 30 and 60 days post-procedure among patients undergoing prostate biopsy within these specific time frames, researchers seek to assess the short-term post-procedural outcomes and potential complications associated with the biopsy procedure. These hospitalization data will provide information into the safety profile and healthcare utilization patterns following prostate biopsy, aiding in the optimization of patient care and risk management strategies.
Number of intra- and perioperative complications associated with 18G and 16G needles30 daysIntraoperative complications refer to adverse events occurring during the biopsy procedure itself, while perioperative complications encompass those arising in the immediate post-procedural period. These complications may include but are not limited to bleeding, infection, urinary retention, and vasovagal reactions. By documenting these complications, investigators will evaluate the safety profile and potential risks associated with each needle gauge, thereby informing clinical decision-making and optimizing patient outcomes.

Countries

Italy

Contacts

Primary ContactFabio F. Zattoni, MD, PhD
fabio.zattoni@unipd.it0498212730

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026