Competence, Procedural Complication
Conditions
Keywords
Central Venous Access, Ultrasound, Ergonomics
Brief summary
The study will compare two different positions of the ultrasound machine during simulated CVC positioning. The position of the ultrasound machine will be randomized. Group A will perform the procedure with the ultrasound monitor facing them, while subjects randomized to group B will perform the procedure with the ultrasound machine positioned at a 90° angle to their visual axis.
Detailed description
We will recruit medical trainees affiliated with the 'Anesthesia and Intensive Care' and 'Emergency Medicine' schools. Data collected for each participant will include: age, gender, specialty school, year of specialization training, expertise in using ultrasound for ultrasound-guided procedures. Once informed consent is obtained, subjects will be divided through simple randomization (a list generated in advance with Excel and subjected to the opaque envelope method) into two groups: A and B. All subjects will be asked to perform CVC placement using the simulator through an 'oblique in-plane' approach. Subjects randomized to group A will perform the procedure with the ultrasound monitor facing them, while subjects randomized to group B will perform the procedure with the ultrasound machine positioned at a 90° angle to their visual axis.
Interventions
Ultrasound machine will be placed in a frontal position
Ultrasound machine will be placed in a lateral position
Sponsors
Study design
Masking description
A clip of the ultrasound procedure will be saved and reviewed by a blind assessor that will value the quality of the procedure
Eligibility
Inclusion criteria
* 'Anesthesia and Intensive Care' and 'Emergency Medicine' residents * Informed consent
Exclusion criteria
* None
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Time to correct CVC position | baseline | Investigators will measure time needed to correctly perform the procedure in seconds. The chronometer will be started when the participant takes the ultrasound probe and will be stopped when the guidewire will be correctly placed |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Needle tip visualization | baseline | Procedure will be recorded as a clip in ultrasound machine. A blind assessor will evaluate the clip using the following scale (1-During the advancement of the needles, only the distortion of the tissue could be observed. 2-Only the tip of the needle was visible. 3-The tip of the needle was visible throughout the advancement, but the body of the needle was only partially visible. 4-The needle was completely visible during its advancement.) |
| Complications | baseline | A complication is defined as participants puncturing the arterial vessel of the simulator |
| Success of the procedure | 10 minutes from the baseline | Procedure will be considered successful if participants will be able to insert the guidewire in a 10 minutes timeframe |
Countries
Italy