Acute Respiratory Distress Syndrome, Ventilator-Induced Lung Injury
Conditions
Brief summary
We aimed to compare mechanical power and energy values using geometric methods at varying inspiratory rise times.
Detailed description
In this study, the researchers aim to compare the mechanical power and energy values calculated using the geometric method in Volume-Controlled Ventilation (VCV) and Pressure-Controlled Ventilation (PCV) modes at different inspiratory rise times.
Interventions
In pressure control ventilation (PCV) mode, patients will be ventilated for 5 minutes at a Tslope of 5% and another 5 minutes at 15% for both 1:1 and 1:2 I:E ratios. After each adjustment, screenshots of the mechanical ventilator (P-V loop screenshots) will be obtained . A total of 20 P-V loop screenshots will be captured over a 20-minute period (10 for the 1:2 ratio and 10 for the 1:1 ratio), which will be stored in the ventilators memory. The stored data will then be transferred from the ventilators memory to a computer via a flash drive.
In volume control ventilation (VCV) mode, patients will be ventilated for 5 minutes at a Tslope of 5% and another 5 minutes at 15% for both 1:1 and 1:2 I:E ratios. After each adjustment, screenshots of the mechanical ventilator (P-V loop screenshots) will be obtained . A total of 20 P-V loop screenshots will be captured over a 20-minute period (10 for the 1:2 ratio and 10 for the 1:1 ratio), which will be stored in the ventilators memory. The stored data will then be transferred from the ventilators memory to a computer via a flash drive.
Sponsors
Study design
Eligibility
Inclusion criteria
* ARDS (Acute Respiratory Distress Syndrome) patients. * Patients who are deeply sedated. * Patients ventilated in: * Pressure-Controlled Ventilation (PCV or PRVC) mode, or * Volume-Controlled Ventilation (VCV) mode. * Patients within the 24-48 hour period of their stay in the intensive care unit.
Exclusion criteria
* Patients with incomplete data. * Patients diagnosed with: * COPD (Chronic Obstructive Pulmonary Disease), * Heart failure. * Pregnant patients. * Patients with a thoracopleural fistula. * Hemodynamically unstable patients.
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| MPgeo | 40 minute | The mechanical power (MPgeo) values measured using the geometric method . |
| Energy | 40 minute | Energy values measured using the geometric method . |
Countries
Turkey (Türkiye)