Skip to content

EasyCrossTM Device-Self-centering Catheter

VIVHEART Transcatheter Aortic Valve Replacement (TAVR) Self-centering Catheter First-in-human Feasibility Trial (VIV-FIH)

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06412354
Acronym
VIV-FIH
Enrollment
20
Registered
2024-05-14
Start date
2024-02-12
Completion date
2024-07-15
Last updated
2026-04-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Transcatheter Aortic Valve Replacement (TAVR)

Brief summary

VIVHEART EasyCross™ is a self-centering device for inserting a guidewire through a heart valve. It consists in a temporary catheter inserted into an artery with a terminal part able to expand a distal structure with 6 arms ("basket") to allow distancing of the catheter from the vessels walls and thus facilitating the passage of the guide wire through the aortic valve. The device is expected to reduce the attempts and the time needed to cross the valve and improves the safety of TAVR procedure

Detailed description

VIVHEART EasyCross™ is a self-centering device for inserting a guidewire through a heart valve. It consists in a temporary catheter inserted into an artery with a terminal part able to expand a distal structure with 6 arms ("basket") to allow distancing of the catheter from the vessels walls and thus facilitating the passage of the guide wire through the aortic valve. The device is expected to reduce the attempts and the time needed to cross the valve and improves the safety of TAVR procedure. EasyCross™ device is a catheter is intended to allow a rapid and safe centering of a heart valve in order to direct and introduce a guidewire through it. The intended purpose is the use of the device during percutaneous TAVR procedures, including TAVR of a native valve, recrossing and balloon post-dilation of a prosthetic aortic valve, or a valve-in-valve aortic valve replacement within the scope of the CE mark. The VIVHEART EasyCross™ device is intended for patients candidate to TAVR of a native valve, recrossing and balloon post-dilation of a prosthetic aortic valve, or a valve-in-valve aortic valve replacement. The suitability of the patient is to be verified case by case by the specialized physician, by means of proper physical examination and instrumental evaluation, according to clinical practice.

Interventions

DEVICEEasyCross™ first-in human

At T0 the patient will undergo the TAVR procedure including the investigational procedure with the VIVHEART EasyCross™ catheter. The interventional cardiologist will introduce the VIVHEART EasyCross™ catheter through the femoral artery with a percutaneous access according to the clinical practice through a vascular introducer on an already positioned guidewire. An operator in the procedure room will start a chronometer at this point to measure the investigational device crossing procedure duration. The VIVHEART EasyCross™ catheter will be progressed into the aorta and up to the aortic valve. At that time the external part of the VIVHEART EasyCross™ catheter will be opened to allow the self-centering of the catheter on the aortic valve. The guidewire will be introduced and once having crossed the valve the VIVHEART EasyCross™ catheter will be retracted by the physician and removed from the patient's body.

Sponsors

Vivheart s.r.l.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Intervention model description

The VIVHEART EasyCross™ fist-in human (VIV-FIH) study is a singlecenter, prospective, open-label, non-randomized, single-group assignment, first-in-human feasibility trial of the VIVHEART EasyCross™ catheter used according to the indication of use. The experimental part of the trial which differs from the traditional TAVR procedure is the use of the self-centering catheter from its insertion in an artery and up to its removal from the patient body (henceforth "investigational procedure").

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age: ≥18 years old * Candidate to TAVR of a native valve, recrossing and balloon postdilation of a prosthetic aortic valve, or a valve-in-valve aortic valve replacement. * Willingness to undergo follow-up visits. * Ability to understand scope, content and risks of the study, and provide informed consent to participation.

Exclusion criteria

* Contraindications for endovascular procedures * Pregnancy or breastfeeding females at screening and at time of investigational procedure * Hemodynamically unstable or other clinical conditions increasing the risk of transcatheter valve procedure failure * Needing emergent procedure * Allergies to components of the device * Allergies to drugs or contrast material that may be used during the investigational procedure and all the TAVR procedure * Participation in another clinical trial

Design outcomes

Primary

MeasureTime frameDescription
Number of Participants With AE /SAE Linked or no Linked With the EasyCross DeviceDay of procedure; 1 week; 4 weekThe primary endpoint is the safety of VIVHEART EasyCross™ catheter, in term of adverse events (AE) and serious adverse events (SAE). Occurrence of any AE will be recorded, in particular the following AE will be coded and investigated as adverse events of special interest (AESI): * Intra-operative death, * Any intra-operative complication due to device malfunction, * Any embolization event, * Any allergic reaction.

Secondary

MeasureTime frameDescription
Time (in Minutes) Spent to Crossing the Valve Witn EasyCross Deviceafter procedureThe secondary endpoints will evaluate the performances of the VIVHEART EasyCross™ catheter in terms of: \- Investigational device crossing procedure duration, assesmed in minutes starting by introduction of Easycross catheter to crossing the valve.

Countries

Italy

Contacts

PRINCIPAL_INVESTIGATORMarco Ancona, Dr.

IRCCS San Raffaele

Baseline characteristics

Characteristic
Age, Categorical
<=18 years
0 Participants
Age, Categorical
>=65 years
20 Participants
Age, Categorical
Between 18 and 65 years
0 Participants
Age, Continuous82 years
Cardiovascular disease14 Participants
Chronic Kidney Disease4 participants
Diabetes4 Participants
Lung diseases0 Participants
Neurological disease0 Participants
Peripheral vascular disease9 Participants
Previous Coronary Artery bypass graft (CABG)0 Participants
Previous Ictus2 Participants
Previous lower limb fracture0 Participants
Previous Percutaneous Coronary Intervention(PCI)3 Participants
Previous pulmonary embolism0 Participants
Previous Surgical Aortic Valve Replacement (SAVR)6 Participants
Previous TAVR1 Participants
Sex: Female, Male
Female
12 Participants
Sex: Female, Male
Male
8 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 20
other
Total, other adverse events
2 / 20
serious
Total, serious adverse events
0 / 20

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Apr 23, 2026