Cardiac Arrest, Simulation of Physical Illness
Conditions
Keywords
Cardiopulmonary Resuscitation, Cardiac arrest, Simulation study, Chest Compressions
Brief summary
The objective of our randomized simulation study on mannequins with a population of Basic Life Support students is to compare the quality of chest compressions, taking depth as the main variable, in two simulated scenarios of out-of-hospital cardiac arrest on a bed: one where Cardiopulmonary Resuscitation is performed on the bed and another where the patient is transferred to the ground for Cardiopulmonary Resuscitation.
Interventions
Uninterrupted 2-minute chest compressions on a manikin that has been moved from the bed to the floor in a simulated scenario of out-of-hospital cardiac arrest
Uninterrupted 2-minute chest compressions on a manikin that is laying on bed in a simulated scenario of out-of-hospital cardiac arrest
Sponsors
Study design
Eligibility
Inclusion criteria
* Those individuals who sign the informed consent and do not meet
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Compressions Mean Depth | On the day of the simulation | Chest Compressions Mean Depth |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Effectiveness of Chest Compressions | On the day of the simulation | Global Punctuation of Chest Compressions in Skillreporter app. |
| Total number of chest compressions | On the day of the simulation | Total number of chest compressions |
| Percentage of chest compressions whit correct depth (5-6cm) | On the day of the simulation | Percentage of compressions whit correct depth (5-6cm) |
| Mean frequency of chest compressions | On the day of the simulation | Mean frequency of chest compressions |
| Time to first chest compression | On the day of the simulation | The time it takes to initiate chest compressions. |
| Percentage of chest compressions with correct position of hands | On the day of the simulation | Percentage of chest compressions with correct position of hands |
| Percentage of chest compressions with correct release | On the day of the simulation | Percentage of chest compressions with correct release |
| Borg Scale for Fatigability | On the day of the simulation | The scale includes a rating of 6 perceiving no exertion at all to 20 perceiving a maximal exertion of effort. |
| Percentage of chest compressions with correct frequency | On the day of the simulation | Percentage of chest compressions with correct frequency |
Countries
Spain