Skip to content

Trans-Abdominal Fetal Pulse Oximetry - EFS-IDE

Trans-Abdominal Fetal Pulse Oximetry - An Early Feasibility Study

Status
Completed
Phases
Early Phase 1
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06405984
Enrollment
35
Registered
2024-05-09
Start date
2024-04-15
Completion date
2025-10-17
Last updated
2025-10-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Fetal Complications, Fetal Conditions, Fetal Distress, Fetal Hypoxia, Labor Fetal Anoxia, Labor (Obstetrics)--Complications, Oxygen Deficiency

Keywords

fetal hypoxia, fetal distress, oxygen deficiency, labor fetal anoxia

Brief summary

The Lumerah System, developed and manufactured by Raydiant Oximetry, Inc., is a non-invasive fetal pulse oximeter that measures fetal arterial oxygen saturation using safe, non-invasive, transabdominal near-infrared spectroscopy. The Lumerah System is intended as an adjunct to cardiotocography. In this study, women in labor will also be simultaneously monitored with a re-engineered version of the previously approved transvaginal oximeter sensor connected to a Nellcor N-400 fetal oximetry monitor for the purposes of device development. The data obtained from the transabdominal sensor and the transvaginal sensor will be used for research purposes only and will not be used to guide or alter patient management.

Detailed description

This is a prospective, interventional, open-label, Early Feasibility Study Investigational Device Exemption (EFS-IDE). The Principal Investigator or research team member will consult a list of eligible patients based on predicted delivery dates and scheduled inductions. Women who are planning to undergo labor will be approached regarding this study. The study involves measurement of the fetal pulse signal with the investigational device, Lumerah, during labor. Lumerah is an investigational fetal pulse oximeter that measures fetal arterial oxygen saturation using safe, non-invasive, transabdominal near-infrared spectroscopy. The Lumerah device is intended as an adjunct to cardiotocography by detecting fetal oxygen deprivation that is both life-threatening to the fetus and can lead to the irreversibly debilitating consequences of newborn metabolic acidosis. The subjects will first undergo sonographic evaluation to assess distance from maternal skin to fetal tissue and to confirm fetal presentation and position during labor. The results of the sonographic measurements might influence the enrollment suitability of the subject as well as the placement of the Investigational device. The Oxiplex TS device, a non-ionizing laser system that provides researchers with valuable information regarding maternal optical tissue properties, will also be used. Once the membranes are ruptured, the investigator's team will use a Nellcor N-400 System with a sterile, single-use transvaginal sensor for data collection only. The outcomes of the fetal oxygenation measurements are masked; only the Sponsor is aware of the measurements. Therefore, no clinical decisions will be made based on the information derived from any of the devices used in this study.

Interventions

DEVICEFetal Oxygenation Measurements

The Lumerah device, and Oxiplex ISS will be positioned on the maternal abdomen in various locations depending on the sonographic evaluation. The transvaginal sensor will be placed after rupture of the maternal membranes and appropriate descent of the fetus.This study is for data collection purposes only. Neonates of this study arm will also be monitored with the Oxiplex ISS system. This study is for data collection purposes only.

Sponsors

National Institutes of Health (NIH)
CollaboratorNIH
Eunice Kennedy Shriver National Institute of Child Health and Human Development (NICHD)
CollaboratorNIH
Raydiant Oximetry, Inc.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DEVICE_FEASIBILITY
Masking
NONE

Masking description

Although it is known what devices are used, all personnel on the investigative team will be masked to fetal oxygenation levels during data collection.

Intervention model description

This is a single-arm, device feasibility study, based on convenience sampling.

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

1. Willing and capable to provide informed consent 2. Age \> 18 years 3. \< 4 cm between maternal skin and fetal skin (determined by ultrasound) 4. Gestational age \> 36 weeks 5. Singleton pregnancy 6. Vertex presentation 7. Active labor 8. Category I and Category II tracings, and 9. Ruptured amniotic sac with cervical dilation of \>2 cm and a station of -2 or lower

Exclusion criteria

1. Age \< 18 years 2. Gestational age \< 36 weeks 3. Multiple gestation 4. Nonvertex fetal presentation 5. Suspected vasa previa 6. Latent labor 7. Category III CTG tracing (i.e., need for immediate delivery) 8. Fetal anomalies and/or chromosomal disorders 9. Chorioamnionitis 10. Placenta Previa 11. History of HIV, Genital Herpes, or other infection precluding transvaginal monitoring 12. Unable to provide informed consent (e.g., cognitively impaired) 13. \> 4 cm fetal depth (determined by Ultrasound), 14. Low anterior placenta, or 15. Any condition (temporary or permanent) in which the investigator deems the patient unsuitable for the study procedures

Design outcomes

Primary

MeasureTime frameDescription
Feasibility of monitoring fetal signals.During labor for up to 6 hoursPrototype device feasibility of detecting reflected optical signals at different wavelengths (colors) from the fetus
Safety of the prototype deviceUp to 72 hours post partumRate of adverse events and serious adverse events

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026