Skip to content

Post Market Evaluation of Clinical Safety and Performance of the Fitbone Transport and Lengthening System

Post Market Evaluation of Clinical Safety and Performance of the Fitbone Transport and Lengthening System

Status
Terminated
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06400732
Enrollment
1
Registered
2024-05-06
Start date
2024-11-19
Completion date
2026-02-28
Last updated
2026-04-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Fracture Nonunion, Fracture of Femur, Fracture of Tibia, Fractures, Bone, Fractures, Closed, Fractures, Open, Limb Asymmetry, Limb Defect, Limb Deformity, Limb Fracture

Keywords

Limb Lengthening, Limb Deformity Correction, Bone Transport

Brief summary

This is an open-label, prospective, observational, post-market, uncontrolled, multi-center study intended to evaluate the safety and clinical performance of the FITBONE Transport and Lengthening Nail when used according to the manufacturer's Instructions for Use. The FITBONE Transport & Lengthening Nail is a variant of the FITBONE TAA Nail, which has been commercially available in the US since 2017. The clinical performance and safety of the medical device have been assessed based on mechanical and biomechanical tests and clinical data obtained from scientific publications on equivalent products. This study intends to prospectively obtain clinical safety and performance data on the device, as used according to the manufacturer's Instructions for Use, in the real-world clinical setting. The data obtained from this study will also be used to provide additional clinical evidence to support product registrations, as required by various regulatory bodies outside the US. Eligible participants will have been selected by their physician to be treated with the FITBONE Transport and Lengthening System as part of treatment for their condition or injury. All procedures will be according to the physician's standard care practices. There are no study-specific procedures or requirements for participants in this study.

Detailed description

This prospective, observational clinical study intends to actively collect clinical data related to the use of the FITBONE Transport and Lengthening System in a representative number of users and patients, observed in the short (\<1yr) and medium (approximately 1 and 2 years) term after implantation of the device. Co-Primary Endpoints: Primary Safety Endpoint: Percentage of unplanned reoperation and/or revision surgery. Instances of re-operation and/or revision as categorized as "planned" or "unplanned" by the surgeon. Primary Performance Endpoint: Percentage of achievement of planned length. Length of the planned transport (and lengthening when applicable) vs the actual overall length of the segment at the time of nail extraction. Secondary Endpoints: * Bone Healing: Radiographic evidence of healing of 3 out of 4 cortices * Consolidation Index: Time to achieve bone healing (days)/ achieved length (cm) * Distraction Index: Time of distraction (days)/ achieved length (cm) * Nail Reliability: Ratio between the number of successfully completed lengthening treatments and the number of implanted lengthening devices * Nail Accuracy: Ratio between the achieved length and the planned length * Time to achieve transport and lengthening * Loss of Range of Motion at full consolidation: degrees from baseline * Nail Extraction complications/failures * Patient-reported outcome measures * Mobility measures * Adverse events Safety Endpoint: The percentage of cases in which unplanned reoperations and/or revision surgery occurred.

Interventions

DEVICEFitbone Transport and Lengthening System

Implantation of the intramedullary Fitbone Transport Nail and subsequent bone segment transport and, optionally, lengthening.

Sponsors

Orthofix Inc.
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. ≥ 18 years old 2. Expressed willingness to participate in the study by signing and dating the informed consent form 3. Has a segmental bone defect, or limb length defect of at least 2 mm up to ≤ 120 mm, considered suitable for correction with an intramedullary lengthening nail, as confirmed by radiographs.

Exclusion criteria

1. Conditions that tend to retard healing such as blood supply limitations, peripheral vascular disease, or evidence of inadequate vascularity 2. Poor bone quality that would prevent adequate fixation of the device 3. Compromised capacity for healing 4. Metal allergies and sensitivities 5. Patients in which the implant would cross open, healthy epiphyseal growth plates 6. Insufficient intramedullary space which would lead to cortical weakening or vascular damage during implantation 7. Body weight of \> 100 kg 8. No free access for proximal insertion of the intramedullary transport and lengthening nail (e.g., coxa valga) 9. No reliable exclusion of bone infection 10. Expected non-compliance, mentally ill patient or patient with clouded consciousness 11. Pregnancy 12. Pre-existing nerve palsies 13. Bone defect larger than 120 mm 14. Gustilo Open Fracture Classification Grade IIIB or IIIC

Design outcomes

Primary

MeasureTime frameDescription
Safety - Percentage of unplanned reoperation and/or revision surgery.1 year post-operativeInstances of re-operation and/or revision as categorized as "planned" or "unplanned" by the surgeon. Specifically, adverse events consisting of re-operation/revision surgery deemed to be related to the device or procedure will be tabulated and the incidence will be determined by dividing this by the total number of patients treated (expressed as %).
Performance - Percentage of achievement of planned lengthening. Length of the planned transport (and lengthening when applicable) vs the actual overall length of the segment at the time of nail extraction.1 year post-operativeIncidence of participants in which successful attainment of target lengthening/distraction was obtained. Specifically, the outcome measure will be based on the difference between the physician's pre-specified target length/distraction to be obtained and the actual lengthening/distraction obtained following treatment. The physician will make a determination if this difference is acceptable for each subject. The incidence of successful lengthening will be determined by the number of clinical acceptable results divided by the total number of patients treated (expressed as %).

Secondary

MeasureTime frameDescription
Effectiveness - Bone Healing1 year and 2 years post-operativeRadiographic evidence of healing of 3 out of 4 cortices
Effectiveness - Consolidation Index1 year and 2 years post-operativeTime to achieve bone healing (days)/ achieved length (cm)
Effectiveness - Distraction Index1 year post-operativeTime of distraction (days)/ achieved length (cm)
Effectiveness - Nail Reliability1 year post-operativeRatio between the achieved length and the planned length
Effectiveness -Time to Transport and Lengthening1 year post-operativeTime to achieve transport and lengthening
Effectiveness - Range of Motion1 year and 2 years post-operativeLoss of Range of Motion at full consolidation; degrees from baseline
Safety -Nail Extraction1 year post-operativeNail extraction complications/failures
Effectiveness - Patient Reported Outcome Measures (PROMs)1 year and 2 years post-operativeImprovement in PROMS scores (Pain, Quality of Life) obtained per standard of care
Effectiveness - Mobility Measuresapproximately 2 years post-operativeImprovement in gait analysis
Safety - Adverse EventsIndex surgery through study completion; approximately 2 years post-operativeEvaluation and classification of all adverse events including device-related, procedure-related and serious adverse events.

Countries

United States

Contacts

STUDY_DIRECTORJay Erturan, MD, JD

Orthofix Inc.

Outcome results

None listed