Skip to content

Long-term Prognosis and Valve Durability of TAVR

Long-term Prognosis and Valve Durability of Transcatheter Aortic Valve Replacement for Aortic Valve Disease: a Real-world, Prospective, Single-center, Observational Study

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06379386
Enrollment
1000
Registered
2024-04-23
Start date
2016-01-31
Completion date
2030-12-31
Last updated
2024-04-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aortic Valve Stenosis and Insufficiency

Keywords

Aortic Valve Disease, TAVR, Prognosis, Valve durability

Brief summary

This registry aims to evaluate the long-term prognosis and valve durability of transcatheter aortic valve replacement (TAVR) in a real-world setting. Baseline characteristics, procedural data, and clinical outcomes will be collected in a prospective and observational manner.

Interventions

PROCEDURETranscatheter aortic valve replacement

A total of 1000 consecutive patients with aortic valve disease undergoing TAVR will be enrolled. Clinical follow-up will be conducted in the periprocedural and after TAVR at 1 month, 5 years, and 10 years

Sponsors

Xijing Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum

Inclusion criteria

Patients diagnosed with severe aortic valve regurgitation undergo evaluation by the Heart team and are eligible for TAVR therapy. 2\. Patients who understand the purpose of this study, agree to participate in the trial and sign the informed consent form * 1\. Patients with aortic stenosis or aortic valve insufficiency who were evaluated by the Heart team and underwent TAVR therapy * 2\. Patients who understand the purpose of the study, agree to participate in the trial and sign the informed consent form

Exclusion criteria

* 1\. Patients who cannot provide informed consent * 2\. Patients who are participating in other clinical trials

Design outcomes

Primary

MeasureTime frameDescription
All-casuse mortality5 yearsAll-casuse mortality including cardiac death and non-cardiac death
Valve-related long-term clinical efficacy5 years* Freedom from bioprosthetic Valve Failure (defined as: Valve- related mortality OR Aortic valve re-operation/re-intervention OR Stage 3 hemodynamic valve deterioration * Freedom from stroke or peripheral embolism (presumably valve-related, after ruling out other non-valve aetiologies) * Freedom from VARC Type 2-4 bleeding secondary to or exacerbated by antiplatelet or anticoagulant agents, used specifically for valve-related concerns (e.g. clinically apparent leaflet thrombosis)

Secondary

MeasureTime frameDescription
Rate of device successdischarge or 30 days* Technical success * Freedom from mortality * Freedom from surgery or intervention related to the device or to a major vascular or access-related or cardiac structural complication * Intended performance of the valve (mean gradient\<20mmHg, and less than moderate aortic regurgitation)
Combined early safety and clinical efficacy outcomes30 daysComposed by all-cause mortality, all strokes, life-threatening or fatal bleeding, major vascular, access-related, or cardiac structural complication, acute kidney injury stage 3 or 4, moderate or severe aortic regurgitation, new permanent pacemaker due to procedure-related conduction abnormalities, conduction block and arrhythmia, surgery or intervention related to the device, any hospitalization, myocardial infarction, any other adverse events
Valve-related long-term clinical efficacy10 years* Freedom from bioprosthetic Valve Failure (defined as: Valve- related mortality OR Aortic valve re-operation/re-intervention OR Stage 3 hemodynamic valve deterioration * Freedom from stroke or peripheral embolism (presumably valve-related, after ruling out other non-valve aetiologies) * Freedom from VARC Type 2-4 bleeding secondary to or exacerbated by antiplatelet or anticoagulant agents, used specifically for valve-related concerns (e.g. clinically apparent leaflet thrombosis)
Combined clinical efficacy outcomes5 years and 10 yearsCombined clinical efficacy outcomes as composed by all-cause mortality (cardiac/non-cardiac), all strokes, any hospitalization
Rate of technical successat exit from procedure room* Freedom from mortality * Successful access, delivery of the device, and retrieval of the delivery system * Correct positioning of a single prosthetic heart valve into the proper anatomical location * Freedom from surgery or intervention related to the device or to a major vascular or access-related, or cardiac structural complication

Countries

China

Contacts

Primary ContactRutao Wang, M.D, Ph.D
rutaowang@qq.com+86-15091095796

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026