Skip to content

Prospective, Multicentre, Randomized, Controlled, Cross-over Study on the Safety and Performance of the Biologic Fusion Option of DialogiQ Compared to Haemodialysis Without Biologic Fusion in Hypotension Prone Patients on Maintenance Haemodialysis

Prospective, Multicentre, Randomized, Controlled, Cross-over Study on the Safety and Performance of the Biologic Fusion Option of DialogiQ Compared to Haemodialysis Without Biologic Fusion in Hypotension Prone Patients on Maintenance Haemodialysis

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06376968
Enrollment
56
Registered
2024-04-22
Start date
2024-04-22
Completion date
2027-06-30
Last updated
2025-09-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Renal Dialysis

Brief summary

The goal of this prospective, randomized, controlled, cross-over, multicentric study is to demonstrate the safety of bioLogic Fusion in patients on chronic haemodialysis or hemodiafiltration prone to hypotensive episodes. The main question it aims to answer is: • Which is the number and percentage of individual sessions with reached prescribed post-dialysis body weight in the prescribed treatment time in each single session in hypotensive-prone patients on high-flux haemodialysis or hemodiafiltration within each patient with treatments performed with DialogiQ with (treatment A) or without (treatment B) the bioLogic Fusion option activated? Participants will in addition to their routine dialysis treatment undergo 2 physical examinations and regularly answer questionnaires. A crossover design is used to compare treatments with or without the BioLogic Fusion function activated.

Interventions

DEVICEBioLogic Fusion

Dialysis conducted with Dialog iQ dialysis machine either using the BioLogic Fusion option or not using it. This is only a biologic feedback system using blood pressure and residual blood volume as parameters to predict potential hypotensive episodes. If switched off, standard dialysis treatment happens, if switched on, the system tries to predict and prevent hypotensive episodes.

Sponsors

B.Braun Avitum AG
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Male or female subjects ≥18 years of age * Chronic bicarbonate standard high-flux haemodialysis or hemodiafiltration for at least 3 months * Dialysis frequency 3 x per week * Dialysis duration per session ≥ 4h * Patient on chronic haemodialysis or hemodiafiltration prone to hypotensive episodes * No residual renal function (definition: ≤100 ml urine/day) - changed to No to minimal residual renal function (definition: ≤ 300 ml/day) with Amendment 1 (CIP version 6) * Stable dry body weight for at least 4 weeks * Subjects who are willing to give a voluntary consent to participate in the study

Exclusion criteria

* Simultaneous participation in another interventional clinical trial (drugs or medical devices studies) * Vascular access insufficiency (mean blood flow \<200ml/min) * Patients treated with dialysis profiles: sodium profile, Ultrafiltration (UF) profile, and temperature profile - changed to: Patients treated with dialysis profiles during the 9 prescreening visits: sodium profile, UF profile, and temperature profile. However, patients on sodium, ultrafiltration or temperature profiling expected to reduce intradialytic hypotensive episodes can be evaluated for enrollment when their frequency of sessions complicated by hypotension demonstrate the lack of efficacy of the applied profiles with Amendment 1 (CIP version 6) * Use of the BioLogic fusion function during the last 9 dialysis sessions recorded at the site (retrospective screening period) * Pregnant or nursing women. Women of childbearing potential must agree to avoid pregnancy during the study period * Factors which may interfere with full participation in the trial * Any contra-indication to haemodialysis treatment per se, as described in the Instructions for Use (IFU) * Any serious medical condition or disability, which in the opinion of the investigator limits the life expectancy and would preclude completion of the study

Design outcomes

Primary

MeasureTime frameDescription
Post-dialysis body weight12 weekspercentage of sessions with reached prescribed post-dialysis body weight