Effect of Breast Size on the Electrical Impedance Tomography Measurement

Effect of Women Breast Size on Lung Monitoring Using Electrical Impedance Tomography

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06369090
Enrollment
22
Registered
2024-04-16
Start date
2013-11-01
Completion date
2014-05-31
Last updated
2024-04-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Effect of Breast Tissue on EIT Lung Monitoring

Keywords

Breast tissue, Electrical impedance tomography, Regional ventilation

Brief summary

Twenty-two healthy female volunteers were monitored using electrical impedance tomogprahy (EIT) in two different situations. First, with electrode belt placed over the breast tissue and second, with the electrode belt under the breast tissue. The EIT measurement was performed with adjunct spirometric measurement. The changes of regional ventilation related to the breast tissue and the size of breast tissue were evaluated.

Detailed description

The EIT measurement (PulmoVista 500, Dräger Medical, Germany) was performed in supine lying position. On every subject, an electrode belt of proper size based on the measured thorax circumference was placed. It was crucial to find a right position where it was possible to place the electrode belt over the breast tissue and then underneath the breast tissue, without changing the level and the position of the electrode belt on the thorax. Also, the position of the belt had to be between 4th and 6th intercostal space, as recommended by the manufacturer. The change of the position of the belt relative to the breast tissue was performed in a lying position by a slight pull of the buckled belt away from the subject´s body, so the subject could relocate the breast tissue over the belt using her own hands into the position as desired by the researcher.

Interventions

DEVICEElectrical impedance tomography (EIT)

Non-invasive, radiation-free bedside lung monitoring using small alternating currents with no known side effects.

Sponsors

Czech Technical University in Prague
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
SUPPORTIVE_CARE
Masking
NONE

Intervention model description

Monitoring of 22 subjects, each subject was measured twice with electrode belt in two different positions.

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 50 Years
Healthy volunteers
Yes

Inclusion criteria

* healthy female volunteers

Exclusion criteria

* morbid obesity * standard

Design outcomes

Primary

MeasureTime frameDescription
Regional ventilation changes possibly caused by the breast tissue30 minutesThe dependence of the regional ventilation evaluated by EIT on the breast size on the regional ventilation was not confirmed.

Secondary

MeasureTime frameDescription
Female subjects enrollment in EIT studies and clinical applications30 minutesRecommendation to include women in studies and clinical applications that use electrical impedance tomography for lung monitoring