Skip to content

Comparison of the Accuracy of Different Intraocular Lens Power Calculation Formulas in Cataract Patients With Prior Radial Keratotomy

Comparison of the Accuracy of Different Intraocular Lens Power Calculation Formulas in Cataract Patients With Prior Radial Keratotomy

Status
Not yet recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06354296
Enrollment
50
Registered
2024-04-09
Start date
2024-04-15
Completion date
2024-08-31
Last updated
2024-04-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cataract

Keywords

cataract, RK surgery, formula

Brief summary

The Web-based Barret True K formula with no history formula has been proven to be a good choice for cataract patients after RK in several studies. The American society of cataract and refractive surgeons provides several IOL formulas for cataract patients who have undergone previous corneal refractive surgery. In cases where only IOL-Master data are available, Holladay 1 (Double-K) \[Holladay 1 (D-K)\] can be used for IOL power calculation in cataract patients with a history of RK. The traditional Haigis formula has also been shown to be effective for cataract patients after RK. To compare the accuracy of four intraocular lens (IOL) power calculation formulas in cataract patients after RK. They are Barrett True-K formula, Holladay 1(D-K) formula, Haigis formula, and MM formula.

Detailed description

Myopia is the most common cause of distance vision impairment. The prevalence of myopia has increased dramatically in the past few decades, especially in China. Corneal refractive surgery is an effective method to correct adult myopia. Radial keratotomy (RK) is one of the corneal refractive surgeries developed in the 1980s. Thirty years ago, many myopic patients underwent RK. As patients age, more and more patients have cataracts requiring cataract extraction and intraocular lens (IOL) implantation. The selection of appropriate and accurate IOL is an important factor to improve patient satisfaction. Recent studies have compared the accuracy of the newly developed IOL formula in patients with previous RK cataract. However, as a country with myopia and myopia surgery, there is no similar study in China. In addition, most patients with cataract after RK had lost ocular data before RK surgery. For RK patients without previous ocular data, how to accurately calculate the IOL power is still a clinical challenge.

Interventions

None listed

Sponsors

He Eye Hospital
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Had a previous history of RK surgery * IOL-Master is available * There were no intraoperative and postoperative complications * Obvious refraction was performed 1 to 6 months after cataract surgery

Exclusion criteria

* The investigator decided that it was not suitable for this study

Design outcomes

Primary

MeasureTime frameDescription
Accuracy of the IOL formulaBaselineTo compare the accuracy of four intraocular lens (IOL) calculation formulas in cataract patients after radial keratotomy (RK). They are Barrett True-K formula, Holladay 1(D-K) formula, Haigis formula, and MM formula

Outcome results

None listed