The Clinical Performance Validation of Electronic Thermometer and Infrared Thermometers

The Clinical Performance Validation of Electronic Thermometer and Infrared Thermometers

Status
Active, not recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06353490
Enrollment
150
Registered
2024-04-09
Start date
2022-08-12
Completion date
2024-08-11
Last updated
2024-04-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Febrile, Healthy

Brief summary

Geon Corporation develops ear thermometers and forehead thermometers that use infrared measurement technology to measure human body temperature. This study verify the accuracy and repeatability of investigational devices. Efficacy verification is carried out by comparing with the referent medical devices. The main objectives of this study are: 1. To verify that the investigational devices and the reference medical devices have a reasonable deviation value. 2. To verify the consistency of repeated measurements of investigational devices.

Detailed description

This Study carried out in accordance with the ISO 80601-2-56: 2017, which included definitions for the age groups and sample sizes, the definition of fever, the flowchart for relevant procedures, and statistical methods for clinical performance. All subjects were measured by the reference device (electronic thermometer MT-B231) and three investigational devices under test evaluation (infrared forehead thermometer GE-TF03, infrared ear thermometer GE-TE06, and electronic thermometer MT-B321FB). For each subject, the reference device measured one time and each investigational device measured three times respectively.

Interventions

DEVICEInfrared Forehead Thermometer (GE-TF03)

Infrared Forehead Thermometer (GE-TF03) is an investigational device intended to measure body temperature on the forehead. GE-TF03 took three measurements for each subject.

DEVICEInfrared Ear Thermometer (GE-TE06)

Infrared Ear Thermometer (GE-TE06) is an investigational device intended to measure body temperature in the ear canal. GE-TF06 took three measurements for each subject.

DEVICEElectronic Thermometer (MT-B321FB)

Electronic Thermometer (MT-B321FB) is an investigational device intended to measure body temperature on the temporal artery. MT-B321FB took three measurements for each subject.

DEVICEElectronic Thermometer (MT-B231)

Electronic Thermometer (MT-B231) is a reference device that measured axillary temperature one time for each subject.

Sponsors

Geon Corporation
Lead SponsorINDUSTRY

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
No minimum to 80 Years
Healthy volunteers
Yes

Inclusion criteria

* Newborn to 80 years old adult * Male or Female * The subject or parent/guardian can talk to the researcher, understand the content of the study after researcher's explanation and agree to sign the subject's consent form, and is willing to accept the trial procedure.

Exclusion criteria

* Currently have signs or symptoms of infection or inflammation at the temperature measurement site (axillary, forehead, ear canal) * The forehead cannot be fully exposed to the environment for more than 15 minutes * Using cooling blankets, fans, or placing ice cubes on the forehead * There is a catheter placed in the ear * Use of antipyretics (such as aspirin, ibuprofen), barbiturates, antipsychotics in the past 2 hours * Received thyroxine, corticosteroids or immunotherapy in the past 7 days * Subject has been diagnosed with cognitive impairment or has a history of dementia, mental illness, mental illness, pervasive developmental disorder, illicit drug use or alcoholism, etc. * Pregnant women * The researcher considers that the subject is not suitable for participating in this trial, such as taking any drugs that may change body temperature * Participated in clinical trials of investigational drugs within the last 30 days * The subject is unwilling to sign the subject's consent form

Design outcomes

Primary

MeasureTime frameDescription
Clinical BiasThrough study completion, an average of 2 yearsMean Difference between investigational thermometer and reference thermometer.
Limits of AgreementThrough study completion, an average of 2 yearsThe magnitude of a potential disagreement between investigational thermometer and reference thermometer.
Clinical RepeatabilityThrough study completion, an average of 2 yearsPooled standard deviation of triplicate measurements over the entire population of subject

Countries

Taiwan