Skip to content

Multicenter Registry of Atrial Fibrillation Ablation With Radiofrequency Balloon Catheter

Multielectrode Radiofrequency Balloon for Atrial Fibrillation Catheter Ablation: A Multicenter Real-World Experience

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06333327
Acronym
COLLABORATE
Enrollment
2000
Registered
2024-03-27
Start date
2021-01-01
Completion date
2030-12-01
Last updated
2024-03-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atrial Fibrillation

Keywords

Radiofrequency, Ablation, Single-shot

Brief summary

All consecutive patients with paroxysmal or persistent atrial fibrillation undergoing pulmonary vein isolation with the radiofrequency balloon catheter (RFB) Heliostar (Biosense Webster) will be included in a multicenter observational registry. The aim of the study is to assess the safety and arrhythmic outcome of atrial fibrillation ablation with the RFB in a real-world setting.

Detailed description

All consecutive atrial fibrillation patients undergoing pulmonary vein isolation (PVI) with the novel radiofrequency balloon catheter (RFB) Heliostar (Biosense Webster) will be prospectively included in a multicenter observational registry. PVI with the RFB will be performed as previously described. Briefly, after optimal RFB positioning, confirmed through the correct alignment between the RFB and the pulmonary vein and sufficient electrode-tissue contact, ablation is performed in temperature-controlled mode with unipolar radiofrequency energy. Typically, \>2 posterior electrodes are identified on the RFB. The power setting is 15 W and the target electrode temperature is 55° C. The same energy is simultaneously delivered to all electrodes, with a duration of 15-20 s for the posterior and 45-60 s for the non-posterior electrodes. During ablation, pulmonary vein potentials are monitored on the circular diagnostic catheter to evaluate real-time isolation. In the case of pulmonary vein acute reconnection, additional applications are delivered to achieve durable PVI. An esophageal temperature probe will be used to monitor any increase in esophageal temperature. Follow-up will be performed according to each standard institutional protocol. Safety endpoints include any major periprocedural complications \[e.g. death, atrioesophageal fistula, stroke/transient ischaemic attack, pericardial effusion/tamponade with/without surgical treatment, myocardial infarction, and persistent phrenic palsy\] occurring within 7 days post-procedure (except for atrioesophageal fistula). Minor complications will also be reported, including vascular access complications requiring treatment, pericarditis, and transient phrenic palsy. Efficacy outcome is defined as arrhythmia-free survival during the follow-up. Arrhythmia recurrence is defined as any atrial tachyarrhythmias ≥30 s after a 90-day post-ablation blanking period.

Interventions

DEVICEPulmonary vein isolation with the multielectrode radiofrequency balloon catheter

Pulmonary vein isolation with the multielectrode radiofrequency balloon catheter

Sponsors

Universitair Ziekenhuis Brussel
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 85 Years
Healthy volunteers
No

Inclusion criteria

* symptomatic atrial fibrillation with indication to catheter ablation

Exclusion criteria

* age \<18 years old * pregnancy * any contraindications to catheter ablation

Design outcomes

Primary

MeasureTime frameDescription
Atrial arrhythmia recurrence after ablationAfter 3 months post-ablation.The primary outcome endpoint is defined as arrhythmia-free survival during the follow-up. Arrhythmia recurrence is defined as any atrial tachyarrhythmias ≥30 s after a 90-day post-ablation blanking period.
Procedural safetyUp to 7 days post-procedure (except for atrioesophageal fistula or pulmonary vein stenosis)The primary safety endpoint included any major periprocedural complications \[e.g. death, atrioesophageal fistula, stroke/transient ischaemic attack (TIA), pericardial effusion/tamponade with/without surgical treatment, myocardial infarction, and persistent phrenic palsy\] occurring within 7 days post-procedure (except for atrioesophageal fistula). Minor complications, including vascular access complications requiring treatment, pericarditis, and transient phrenic palsy will also be assessed.

Countries

Belgium

Contacts

Primary ContactAlexandre Almorad, MD
alexandre.almorad@uzbrussel.be+32 2 4776009

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026