Plethysmographic Perfusion Index and Fluid Responsiveness

Reliability of Plethysmographic Perfusion Index to Predict Fluid Responsiveness in Acute Circulatory Failure.

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06313671
Acronym
PPI-FR
Enrollment
50
Registered
2024-03-15
Start date
2024-02-10
Completion date
2024-09-10
Last updated
2025-03-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Fluid Responsiveness

Keywords

acute circulatory failure, fluid responsiveness, perfusion index, left ventricular outflow velocity time-integral, echocardiography

Brief summary

The objective of this study is to assess the reliability of the perfusion index to predict fluid responsiveness in patients with acute circulatory failure in intensive care.

Detailed description

In patients with acute circulatory failure, it is recommended to assess fluid responsiveness. Fluid responsiveness is defined by an increase in cardiac output of 10 to 15% after fluid loading. The assessment of fluid responsiveness usually needs cardiac output monitoring (or stroke volume). However, in limited resource settings or during the initial management of patients with acute circulatory failure, cardiac output measurement is usually unavailable. The perfusion index (PI) is derived from the plethysmographic signal of the pulse oximeter and represents the ratio between the ratio of pulsatile on non-pulsatile light absorbance of the plethysmography signal. The PI is influenced by vascular and stroke volume. The investigators hypothesized that the peripheral index could track the changes in cardiac output induced by fluid loading and therefore detect fluid responsiveness. Adult patients with acute circulatory failure in whom physicians want to test the fluid responsiveness will be included. At baseline, the PI will be recorded. An initial echocardiography will be performed to measure the left ventricular outflow tract velocity time integral (a surrogate of stroke volume). A fluid loading with 500 ml of 0.9% Saline or Ringer Lactate will be performed. After fluid administration, the velocity time integral and the PI will be collected. Fluid-responsive patients are defined by a 15% increase in velocity time integral. The investigators will analyze the ability of the PI to detect fluid responsiveness.

Interventions

DIAGNOSTIC_TESTPerfusion index

The perfusion index (PI) is derived from the plethysmography signal and represents the ratio of pulsatile to non-pulsatile light absorbance of the plethysmography signal. PPG signal.

Sponsors

Avicenna Military Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

Patients aged 18 and older with acute circulatory failure (ACF).

Exclusion criteria

* Low echogenicity: the inability to perform echocardiographic measurements according to established recommendations. * Absence of the plethysmographic signal.

Design outcomes

Primary

MeasureTime frameDescription
Reliability and accuracy of the perfusion index to discriminate fluid-responsiveness.through study completion, an average of 9 months.Reliability and accuracy of the change in perfusion index to discriminate fluid-responsive patients. Fluid responsiveness is defined by an increase in the left ventricular outflow tract velocity time integral by 15% after fluid loading.