Skip to content

Artificial Intelligence & Prostate Cancer

The Role of Artificial Intelligence in the Assessment of Multiparametric Resonance of the Prostate in Prostate Cancer Patients

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06298305
Acronym
QUANTIB
Enrollment
200
Registered
2024-03-07
Start date
2023-03-08
Completion date
2024-09-02
Last updated
2026-05-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Prostate Cancer

Brief summary

This is a single center, blinded (the mpMRI will be read by expert personnel not aware of the patient's diagnosis ), retrospective study. A total of 200 patients with suspicious prostate cancer (PCa) who underwent, between January 2014 and January 2022, mpMRI of the prostate and subsequent prostate biopsy will identified. All mpMRI images will be retrospectively collected and evaluated using the Quantib Prostate software. In particular, 200 mpMRI with endorectal coil will be read by the expert radiologist and by the Quantib prostate (Quantib B.V. Rotterdam, The Netherlands) software, thus evaluating the predictive characteristics of Quantib Prostate for the identification of suspicious lesions. The sensitivity, specificity, negative predictive value, positive predictive value and accuracy of Quantib Prostate vs. radiologist in detecting csPCa will be evaluated using the biopsy report as reference standard.

Detailed description

An increasing number of certified software using AI in radiology is becoming available. Nonetheless, the role of AI in the detection of prostate lesions at mpMRI in men with suspicious PCa is still under debate. Specifically, it is unknown whether the use of AI may help clinicians in the decision-making process with a reliable inter-observer agreement compared to assessments done by high-volume experienced dedicated uro-radiologists. In this context, the use of digital platforms available on the market such as Quantib Prostate (Quantib B.V. Rotterdam, The Netherlands) could help in the identification of patients at higher risk of clinically significant PCa (csPCa). Among the other platforms, Quantib Prostate has a validated algorithm for the evaluation of prostate MRI which has been already tested in the clinical setting and which holds a CE mark and authorization for clinical use. Moreover, the use of Quantib Prostate may lead to advantages in terms of time reduction, time-efficiency and diagnostic performance compared with the traditional radiologist approach, with a potential impact on report quality.For these reasons, among the various AI softwares which are currently available, we decided to select Quantib Prostate for these analyses. The potential implication of this study includes: 1. Establishing inter-observer agreement between AI and traditional radiologist approach 2. Time reduction in the diagnosis of suspicious PCa 3. Error reduction within the imaging workflow

Interventions

DEVICEQuantib prostate (Quantib B.V. Rotterdam, The Netherlands) software

Quantib Prostate is an AI-driven solution that provides an intuitive workflow for assessment of prostate MRI. The product integrates essential prostate MRI reading features into one workflow making it easy for the user to read, assess and report each patient case from within the same software interface. With automatic forwarding in place, the software preprocesses the MRI right after scanning. This allows the user to access calculations and analysis immediately when they open the software interface. Thanks to these features, the professional may experience an accelerated workflow, making it easier to manage their heavier workload.

Sponsors

IRCCS San Raffaele
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
MALE
Age
18 Years to No maximum

Inclusion criteria

1. Men at least 18 years of age referred with clinical suspicion of prostate cancer 2. Men who have undergone mpMRI and subsequent targeted plus random systematic prostate biopsies 3. Available pathological report with details regarding the site of positive cores and grade group 4. Serum PSA ≤ 20 5. Patient who underwent a 1.5T mpMRI with or without endorectal coil with the following protocol restrictions and according to recent European Guidelines, each case containing at least the following sequences, will be considered: T2w * No fat suppression * At least axial acquisition * Max voxel size 1.0x1.0x3.0mm DWI * At least on b-value ≥800 s/mm\^2 required, ≥1400 s/mm\^2 preferred * ADC map required * Max voxel size: 2.0x2.0x4.0mm * Axial scanning protocol only DCE scan * Recommended temporal resolution \<15s * Axial scanning protocol only

Exclusion criteria

NA

Design outcomes

Primary

MeasureTime frame
To evaluate the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy in detecting csPCa of Quantib Prostate vs. traditional radiologist reading of mpMRI12

Secondary

MeasureTime frame
To assess the impact of Quantib Prostate in predicting pathologic outcomes in patients who received radical prostatectomy12
To report time reduction in the diagnosis of suspicious PCa12

Countries

Italy

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: May 19, 2026