Skip to content

Effectiveness and Safety of Coronary Scoring Balloon Dilation Catheter in the Pretreatment of Coronary Stenosis Lesions

A Prospective, Multicenter, Randomized Controlled, Non-inferiority Design Clinical Trial, To Evaluate the Efficacy and Safety of the Coronary Artery Notched Balloon Dilation Catheter for the Pre-dilation of Coronary Artery Stenosis Lesions

Status
Not yet recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06291545
Enrollment
200
Registered
2024-03-04
Start date
2024-03-20
Completion date
2025-06-30
Last updated
2024-03-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease

Brief summary

This trial adopts a prospective, multicenter, randomized controlled, and non-inferiority comparison trial design, and plans to recruit 200 eligible subjects who will be randomly assigned to the experimental group or the control group in a 1:1 ratio. All randomly enrolled subjects will be followed up until 30 days after the surgery.

Detailed description

This trial uses a prospective, multicenter, randomized controlled, non-inferiority comparison design. It is expected that the test group will be non-inferior to the control group in the main effectiveness evaluation index (device success rate). This trial plans to enroll 200 subjects who meet the requirements, and they will be randomly assigned to the test group or the control group in a 1:1 ratio. All randomly enrolled subjects will be followed up for 30 days after percutaneous coronary intervention (PCI) treatment to compare the test group and the control group in the main effectiveness evaluation index (device success rate), secondary effectiveness evaluation indices (immediate lumen gain \[QCA analysis\], surgical success rate, in-hospital major adverse cardiac event \[MACE\] incidence rate, target lesion failure \[TLF\] incidence rate within 30 days after surgery, patient-related composite endpoints \[PoCE\] incidence rate during and within 30 days after surgery, device operation and performance evaluation), and safety evaluation indices (device-related complication incidence rate, adverse event/serious adverse event incidence rate, device defect incidence rate), in order to evaluate the effectiveness and safety of the coronary scoring balloon dilation catheter of the test medical device.

Interventions

DEVICECoronary artery scoring balloon dilation catheter(JW Medical Systems Ltd)

One hundred subjects who met the inclusion and exclusion criteria were enrolled and assigned to the Coronary artery scoring balloon dilation catheter treatment group.

DEVICEScoreFlex NC Coronary Dilatation Catheter

One hundred subjects who met the inclusion and exclusion criteria were enrolled and assigned to the ScoreFlex NC Coronary Dilatation Catheter treatment group.

Sponsors

JW Medical Systems Ltd
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* 1\. Voluntary participation in this trial and signed the informed consent form; * 2\. Age: ≥18 and ≤80 years old, regardless of gender; * 3\. The existence of coronary artery stenosis lesions accompanied by evidence of ischemia in the heart (such as symptomatic coronary heart disease, stable/unstable angina pectoris or asymptomatic myocardial ischemia), suitable for percutaneous interventional therapy.

Exclusion criteria

* 1\. Acute myocardial infarction (AMI) within 7 days before surgery; * 2\. Serum creatinine level \>2.0 mg/dL (177 umol/L) within 7 days before surgery; * 3\. Active peptic ulcer or active gastrointestinal bleeding within 1 month before surgery; * 4\. Stroke or transient ischemic attack (TIA) within 3 months before surgery; * 5\. Known left ventricular ejection fraction (LVEF) \<30% (if LVEF is unknown, it can be measured during this surgery); * 6\. Known allergies to aspirin or heparin or the existence of contraindications that prevent the subjects from receiving sufficient preoperative medications; * 7\. Known subjects allergic to ingredients in the test product or contrast agent; * 8\. Known subjects who are pregnant or breastfeeding; * 9\. Planned to use coronary atherectomy, laser ablation, other scoring / spiked / cutting balloons (non-study devices) or shock wave balloons to treat the target lesion at the same time; * 10\. Subjects participating in other drug or device clinical studies; * 11\. Other situations that are not suitable for participation in this study as assessed by the investigator.

Design outcomes

Primary

MeasureTime frameDescription
Rate of successful device usage1hourThe investigational device was successfully delivered to the intended target lesion, dilated, deflated, and retrieved smoothly; After balloon angioplasty with the investigational device, the residual stenosis of the target lesion diameter was \<50%.

Secondary

MeasureTime frameDescription
Rate of success of the surgery3 daysThe success of the surgery is defined as on the basis of successful use of the instrument, the residual stenosis of the target lesion diameter after PCI is ≤ 30% and TIMI blood flow is grade 3, and no MACE occurs in the hospital.
Incidence of in-hospital MACE30 daysMACE includes cardiac death, target vessel myocardial infarction, and target lesion re-vascularization
Incidence of PoCE within 30 days after surgery30 daysPoCE includes all-cause mortality, all MIs, and any re-vascularization
The lumen is obtained immediately1hourThe lumen is obtained immediately (QCA analysis)

Contacts

Primary ContactYang Wang, PM
yang.wang@jwmsgrp.com13366024088

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026