Skip to content

Trueness of Full Arch Scans and Generated Digital Implant Models

Assessment of Accuracy of Full Digital Workflow in Fabrication of Four-Implant Screw-Retained Mandibular Hybrid Prostheses

Status
Not yet recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06281002
Enrollment
9
Registered
2024-02-28
Start date
2024-04-30
Completion date
2024-12-31
Last updated
2024-03-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Complete Edentulism, Denture

Keywords

Intraoral scanning, Digital implant models, Edentulous mandible, Screw retained prosthesis, Geometric scanning aids

Brief summary

The goal of this clinical trial study is to evaluate the accuracy of the full digital workflow for four-implant, screw-retained mandibular hybrid prostheses in patients with completely edentulous mandible.

Detailed description

The main issues to evaluate are: * The trueness of full arch digital scans when additional geometric scanning aids are coupled with the scan bodies. * The trueness of the generated 3D-printed DIMs. Participants will provide two types of impressions to compare after osteointegration; the first will be conventional open tray impression used as a gold standard comparator, the second will be digital scans with additional geometric scanning aids coupled with the scan bodies. Accordingly generated 3D-printed DIMs will be printed and compared to the digital image to evaluate its accuracy.

Interventions

DEVICEconventional impression stone casts digitization

Nine conventional physical open tray impressions will be poured into a hard dental stone to obtain nine definitive implant casts with conventional implant analogs to act as a reference comparator. Impressions will be digitized to reference STL files.

DEVICEdigital scanning with coupled scanning aiding device

Nine optical impressions will be obtained while additional geometric scanning aids are coupled with the scan bodies to get nine CAD/CAM 3D-printed polymer casts with digital implant analogs.

DEVICEDigital Implant Model assessment of accuracy

The nine STL files of optical scanning will serve as reference data for comparison with the digitized DIMs to evaluate the accuracy of representation of the actual position of implants in the software.

Sponsors

Ain Shams University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
45 Years to 60 Years
Healthy volunteers
Yes

Inclusion criteria

* Patients having a completely edentulous lower arch that could be restored by fixed screw-retained implant hybrid dentures. * Patients having a substantial bone height and width at prospective implant sites to install four standard-size inter-foraminal implants. * Sufficient crown height space according to criteria of all-on-4. * good oral hygiene and motivation

Exclusion criteria

* Patients with bad oral hygiene. * Patients with limited mouth opening. * Vulnerable groups. * Uncooperative patients. * Patients receiving or undergoing radiotherapy or chemotherapy. * Patients with systemic diseases affecting bone metabolism. * Smokers

Design outcomes

Primary

MeasureTime frameDescription
Trueness of full arch digital scans when additional geometric scanning aids are coupled with the scan bodies.2 monthsThe optical impressions will be obtained by an intraoral scanner while the scan abutments are coupled with 3D geometric scanning aids and seated in positions. special digital software will be used to compare the trueness of virtual implant positions in the obtained digital scan STL files to the digitized reference positions in the patients' digitized conventional stone model

Secondary

MeasureTime frameDescription
Trueness of the generated 3D-printed digital implant models.2 monthsBased on the obtained optical scans, CAD software will be used to produce CAM files of definitive implant casts, the polymer casts will be printed and the digital implant analogs will be installed in their corresponding positions in the printed DIMs. The digitized data of the DIMs will be compared to their corresponding reference STL files of optical scans to check the accuracy of the generated digital implant models.

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026