Skip to content

Prognostic Value of High-resolution Electrical Source Imaging on the Success of Pediatric Focal Epilepsy Surgery

ISEPEE : Prognostic Value of High-resolution Electrical Source Imaging on the Success of Pediatric Focal Epilepsy Surgery

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06271785
Acronym
ISEPEE
Enrollment
120
Registered
2024-02-22
Start date
2024-05-15
Completion date
2026-11-15
Last updated
2025-09-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Epilepsy in Children

Brief summary

This study investigates the usefulness of high resolution electrical source imaging (HR-ESI) in the setting of presurgical evaluation of drug-resistant focal epilepsy in children. This method is based on an estimation of the intra-cerebral source that produces a signal recorded by scalp electrodes by solving the inverse problem, taking into account attenuation factors resulting from particular conductivity properties of the cerebral, peri-cerebral and cranial tissues. Electrical sources are then fused on structural magnetic resonance imaging (MRI). Scalp EEG recorded using 64 to 256 electrodes refers to as high resolution EEG (HR-EEG), leading to HR-ESI. Studies based on small population of children or on mixt population of children and adults showed that HR-ESI has accuracy values, i.e. percentage of true positives (electrical source localized in the brain area resected and success of surgery) and true negatives (electrical source localized outside the brain area resected and failure of surgery) among the total population, ranging from 50 to 80%. Discrepancies between studies could be explained by the limited number of patients included or by the mixture of pediatric and adult data. Another limitation of previously published studies is that the spatial pattern of dipole source distribution was not taken into account to determine prediction accuracy of ESI. Studies using magnetoencephalography (MEG) to perform magnetic source imaging (MSI) suggest that the spatial pattern of dipole source distribution needs to be considered, a spatially-restricted dipole distribution being associated with better post-surgical outcome when resected. To tackle these issues, the investigators aim to conduct the first large prospective multicentric study in children with focal epilepsy candidates to surgery to assess prediction accuracy of ESI based on the finding of tight clusters of dipoles. This is original as this pattern (tight versus loose cluster of dipoles) has been studied by several researchers using MEG but not using HR-EEG. The investigators make the hypothesis that HR-EEG will allow to identity good candidates for epilepsy surgery and thus to offer this underutilized treatment in more children with better post-surgical outcome. Among the secondary objectives, the investigators will address methodological issues related to the resolution of the inverse problem (methods using distributed sources models versus methods based on equivalent dipole estimation), the potential added value to model high-frequency oscillations (HFO), and the investigators will assess the cost-utility of the HR-ESI procedure.

Detailed description

This study investigates the usefulness of high resolution electrical source imaging (HR-ESI) in the setting of presurgical evaluation of drug-resistant focal epilepsy in children. This method is based on an estimation of the intra-cerebral source that produces a signal recorded by scalp electrodes by solving the inverse problem, taking into account attenuation factors resulting from particular conductivity properties of the cerebral, peri-cerebral and cranial tissues. Electrical sources are then fused on structural magnetic resonance imaging (MRI). Scalp EEG recorded using 64 to 256 electrodes refers to as high resolution EEG (HR-EEG), leading to HR-ESI. Studies based on small population of children or on mixt population of children and adults showed that HR-ESI has accuracy values, i.e. percentage of true positives (electrical source localized in the brain area resected and success of surgery) and true negatives (electrical source localized outside the brain area resected and failure of surgery) among the total population, ranging from 50 to 80%. Discrepancies between studies could be explained by the limited number of patients included or by the mixture of pediatric and adult data. Another limitation of previously published studies is that the spatial pattern of dipole source distribution was not taken into account to determine prediction accuracy of ESI. Studies using magnetoencephalography (MEG) to perform magnetic source imaging (MSI) suggest that the spatial pattern of dipole source distribution needs to be considered, a spatially-restricted dipole distribution being associated with better post-surgical outcome when resected. To tackle these issues, the investigators aim to conduct the first large prospective multicentric study in children with focal epilepsy candidates to surgery to assess prediction accuracy of ESI based on the finding of tight clusters of dipoles. This is original as this pattern (tight versus loose cluster of dipoles) has been studied by several researchers using MEG but not using HR-EEG. The investigators make the hypothesis that HR-EEG will allow to identity good candidates for epilepsy surgery and thus to offer this underutilized treatment in more children with better post-surgical outcome. Among the secondary objectives, the investigators will address methodological issues related to the resolution of the inverse problem (methods using distributed sources models versus methods based on equivalent dipole estimation), the potential added value to model high-frequency oscillations (HFO), and the investigators will assess the cost-utility of the HR-ESI procedure. The study focuses on epileptic children who are candidates to a procedure of epilepsy surgery aiming to make them seizure-free. The principle of epilepsy surgery is to remove the brain area that generates patient's seizures, i.e. the seizure onset zone (SOZ). Candidates are patients with focal seizures that do not completely respond to the medical treatment and impact their quality of life. This represents 5-10% of epileptic children. Pre-surgical evaluation of these patients consists to perform in a first step non-invasive methods aimed to localize the SOZ: video-EEG in order to characterize usual seizures of the patient and to record and localize interictal epileptiform discharges (IED), MRI to search for a structural epileptogenic lesion, and positron emission tomography (PET) with fluorodeoxyglucose (FDG) to search for a brain area showing abnormal FDG uptake. After this so-called phase 1 work-up, the case is discussed in a multidisciplinary meeting, resulting in one of the 3 following decisions: (1) surgical resection when information from phase 1 is considered as sufficient, (2) continuation of the surgical process by performing a phase 2 evaluation, i.e. an invasive EEG recording using intracranial electrodes implanted by stereotaxy (SEEG), when information from phase 1 is considered as insufficient but made possible to pose a hypothesis regarding the localization of the SOZ, and (3) rejection for surgery. In children, epilepsy makes patient seizure-free in 60-80% of the cases. HR-ESI is a relatively new method that has been developed to localize non-invasively the SOZ with the hope to decrease the number of patients rejected for surgery or oriented to phase 2, and to increase the rate of success of epilepsy surgery.

Interventions

DIAGNOSTIC_TESTHR-EEG recording

All participants will have a HR-EEG recordings. It will be made at rest. Nap-like sleep is encouraged, but no sedatives will be given. Recording time will not exceed two hours.

Sponsors

University Hospital, Angers
Lead SponsorOTHER_GOV

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
2 Years to 17 Years
Healthy volunteers
No

Inclusion criteria

1. Age≥2 and \<17 years; 2. Drug-resistant focal epilepsy (failure of at least 2 well-conducted drug trials); 3. Phase 1 pre-op evaluation with scalp video-EEG recording, MRI and PET-FDG suggesting that the patient could be a good candidate for epilepsy surgery; 4. Recent scalp EEG record (within 12 months) showing the presence of interictal spikes; 5. High-quality and recent (within 6 months) structural MRI with 3D-T1 sequences covering the whole brain and the scalp available.

Exclusion criteria

1. Behavioral deficits making recording of scalp EEG impossible without sedation; 2. Informed consent form not signed by the parents; 3. Patient not affiliated to a social security system

Design outcomes

Primary

MeasureTime frameDescription
Prediction accuracy index24 monthsThe main outcome is the prediction accuracy index, as assessed in fusing pre-op current equivalent dipoles to postop MRI, based on a tight cluster of spikes compared to the prediction accuracy index based on a loose cluster of spikes or on multiple clusters of spikes.

Secondary

MeasureTime frameDescription
Localization of the epileptogenic zone (After Surgery)24 months (= V3)To assess the ability of HR-ESI to localize the epileptogenic zone. Spatial congruence between the brain areas involved by the sources of interictal spikes and the epileptogenic zone, defined by either a MRI lesion concordant with the electroclinical data, or the brain area resected in patients who achieved good outcome following surgery.
preoperative accuracy of epileptogenic source localization12 months (= V2)To determine the preoperative accuracy of epileptogenic source localization delineated by HR-ESI. Spatial congruence between the brain areas involved by the sources of interictal spikes and the SOZ as assessed by intracranial EEG in patients oriented to intracranial EEG investigation.
Localization of the epileptogenic zone (Baseline)BaselineTo assess the ability of HR-ESI to localize the epileptogenic zone. Spatial congruence between the brain areas involved by the sources of interictal spikes and the epileptogenic zone, defined by either a MRI lesion concordant with the electroclinical data, or the brain area resected in patients who achieved good outcome following surgery.
Impact of method of sources reconstruction, conditions of EEG recordings and sampling rate3 months (= V1)To study the influence of some factors that could impact results of HR-ESI: type of method of sources reconstruction, conditions of EEG recordings (awake state versus sleep), and sampling rate. Congruence of the brain areas identified by HR-ESI according to the methods of sources reconstruction, the type of spikes (awake versus sleep) and the sampling rate.
health-economic modeling24 months (= V3)To perform a health-economic modeling to assess cost-utility and cost-effectiveness of the HR-ESI procedure. Evolution of Quality of life assessed with Child Health Utility 9 Dimensions (CHU9D) questionnaire
prognostic value of HFO24 months (= V3)To determine the prognostic value of epileptogenic source localization delineated by HR-ESI based on high-frequency oscillations (HFO), on successful epilepsy surgery. Prediction accuracy index, as assessed in fusing pre-op current equivalent dipoles to postop MRI, based on of a unique, well delineated and completely resected cluster of HFO, compared to other situations.

Countries

France

Contacts

Primary ContactPatrick Van Bogaert, Professor
Patrick.VanBogaert@chu-angers.fr+33 2 41 35 48 46

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026