Skip to content

Examining Factors Influencing Thoracolumbar Mobility in Runners

Examining Factors Influencing Thoracolumbar Mobility in Amateur Runners and Sedentary Individuals

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06269224
Enrollment
90
Registered
2024-02-21
Start date
2022-09-01
Completion date
2024-01-01
Last updated
2024-02-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Fascia, Mobility, Range of Motion, Runners

Keywords

running, Latissimus Dorsi, Tone, Elasticity

Brief summary

The presence of to is thoracolumbar (TL) mobility a significant aspect in the context of running. Most of the factors may be related to certain kinematic parameters of the lumbopelvic-hip complex during running.

Detailed description

Context: The presence of to is thoracolumbar (TL) mobility a significant aspect in the context of running. Most of the factors may be related to certain kinematic parameters of the lumbopelvic-hip complex during running. Objective: To compare the TL mobility of individuals at different running levels and sedentary individuals. Design: Cross-sectional. Participants: The first group consisted of 35 runners who had been running for the last two years (RTY) while the second group had 35 runners who had been running for the last six months (RSM). The third group had 35 sedentary individuals. Main Outcomes Measures: Sports-related and sociodemographic information was recorded. The Myoton device was used over the Latissimus Dorsi (LD) muscle on both dominant and nondominant sides to measure muscle tone (Hz), elasticity, and stiffness (N/m) values. Trunk flexibility and flexibility of lumbar extensor muscles were measured with tape measurement (cm). The trunk range of motion (ROM, ˚) was measured using goniometer. Thoracolumbar Fascia Length Test and Modified Schober Test were used for thoracolumbar (TLF) fascia flexibility. Analysis of variance was used for statistical analysis. SPSS version 17.0 was used for all statistical analyses. The primary outcome was defined as lumbar extensor tightness. Numeric data obtained from the subjects were presented as mean, standard deviation (mean±SD) and percentage (%). The primary outcome was defined as lumbar extensor tightness. The sample size for each group was calculated to be 30 with a power of 80% and a significance level of 0.05. Considering potential dropouts, 35 participants were included in each group. The groups were not homogenous. As a nonparametric test, the 'Kruskal-Wallis test' was employed for the three-group comparison. The Mann-Whitney U test was used for the two-group comparison. Statistical significance was set at P \< .05.

Interventions

OTHERParticipants were recreational runners who run between 20 to 50 km weekly; each one has 35 runners.

The Myoton device was used over the Latissimus Dorsi (LD) muscle on both dominant and nondominant sides to measure muscle tone (Hz), elasticity, and stiffness (N/m) values. Trunk flexibility and flexibility of lumbar extensor muscles were measured with tape measurement (cm). The trunk range of motion (ROM, ˚) was measured using goniometer. Thoracolumbar Fascia Length Test and Modified Schober Test were used for thoracolumbar (TLF) fascia flexibility. The weekly training distance (km), duration (h) and daily water consumption (lt) rates were recorded. The percentage of individuals experiencing lower extremity injuries and lower back pain within the RSM group was calculated.

Sponsors

Hacettepe University
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
30 Years to 45 Years
Healthy volunteers
No

Inclusion criteria

* The participants were within the age range of 30 to 45.

Exclusion criteria

* The history of lower extremity or lumbar-related surgery within the last year and a body mass index (BMI) exceeding the normal threshold of 24.5 kg/m².

Design outcomes

Primary

MeasureTime frameDescription
Myoton Assessment1 monthThe passive mechanical properties of the muscle (Tone, Stiffness, and Elasticity) were measured using the Myoton-3 myotonometer medical device (Myoton Ltd., Estonia, EU) (ICC: 0.80-0.93). The patients were positioned prone with a thin rolled towel placed under their foreheads and their arms in a 180˚ flexion position for a fifteen-minute period of rest. In our study, a point 5 cm below the lower tip of the scapula was identified along the imaginary line of the LD muscle. The probe was at a 90˚ angle to the skin. The measurements were repeated ten times at one-second intervals and the average values were recorded. These values were then calculated for dominant and nondominant sides.

Countries

Turkey (Türkiye)

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026