Skip to content

QStat Cartridge in Obstetric Patients

Evaluation of the Clinical Performance of the Quantra® System With the QStat® Cartridge in Obstetric Patients

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06255496
Enrollment
296
Registered
2024-02-13
Start date
2024-05-09
Completion date
2025-10-30
Last updated
2025-11-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Blood Loss Massive, Post Partum Hemorrhage

Keywords

Quantra, Viscoelastic testing, Coagulation

Brief summary

This study will assess the performance of the Quantra System with the QStat Cartridge versus standard of care coagulation testing in pregnant women at risk of bleeding at delivery.

Detailed description

The Quantra System is a fully integrated and automated in vitro diagnostic device which uses SEER Sonorheometry, an ultrasound-based technology, to characterize the viscoelastic properties of a whole blood sample during coagulation. The QStat Cartridge was developed to monitor hemostasis in patients that may experience a range of coagulopathies of various etiologies including fibrinolytic defects. These patients include the tobstetric hemorrhage population. The cartridge consists of four independent channels each containing different sets of reagents, which provide four measurements performed in parallel yielding five parameters that depict the functional status of a patient's coagulation system. This multicenter, prospective, observational pilot study will evaluate the performance of the Quantra System with the QStat Cartridge as compared to standard of care coagulation testing in pregnant women at risk of bleeding at delivery.

Interventions

DIAGNOSTIC_TESTQuantra Hemostasis Analyzer with the QStat Cartridge

Diagnostic device to monitor coagulation properties of a whole blood sample at the point-of-care.

Sponsors

HemoSonics LLC
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 50 Years
Healthy volunteers
No

Inclusion criteria

* Subject is greater than18 years. * Subject is pregnant or at least 24 h postpartum * Conventional coagulation tests and/or viscoelastic testing are ordered for concern of possible coagulopathy based on one or more clinical scenarios including hemorrhage, suspected or confirmed placental abruption, amniotic fluid embolism, or placenta accreta spectrum * Subject or subject's LAR is willing to provide informed consent, either prospectively or by deferred consent.

Exclusion criteria

* Subject is younger than 18 years old. * Subject or subject's LAR is unwilling or unable to provide informed consent, either prospectively or by deferred consent. * Subject is incarcerated at the time of the study. * Subject is currently enrolled in a distinct study that might confound the results of the proposed study * Subject is affected by a condition that, in the opinion of the clinical team, may pose additional risks

Design outcomes

Primary

MeasureTime frameDescription
Comparison of Quantra Clot Time to laboratory aPTT test resultsAt the time hemorrhage is suspected, anticipated within 24 hours after birthCoagulation function assessed by Quantra Clot Time (CT, sec) and activated partial thromboplastin (aPTT, sec) test
Comparison of Quantra Fibrinogen Contribution to Clot Stiffness to laboratory coagulation fibrinogen test resultsAt the time hemorrhage is suspected, anticipated within 24 hours after birthCoagulation function assessed by Quantra Fibrinogen Contribution to Clot Stiffness (FCS, hPa) and Clauss fibrinogen (mg/dL) test
Comparison of Quantra Clot Time to ROTEM delta INTEM CT test resultsAt the time hemorrhage is suspected, anticipated within 24 hours after birthCoagulation function assessed by Quantra Clot Time (CT, sec) and ROTEM INTEM CT (sec) test
Comparison of Quantra Fibrinogen Contribution to Clot Stiffness to ROTEM delta FIBTEM test resultsAt the time hemorrhage is suspected, anticipated within 24 hours after birthCoagulation function assessed by Quantra Fibrinogen Contribution to Clot Stiffness (FCS, hPa) and ROTEM FIBTEM (mm) test

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026