Concordance Between the Measurement of Whole Blood Fibrinogen by the qLabs®FIB Analyzer and Its Measurement by Conventional Method (Clauss Fibrinogen) in the Context of Severe Postpartum Haemorrhage

Concordance Between the Measurement of Whole Blood Fibrinogen by the qLabs®FIB Analyzer and Its Measurement by Conventional Method (Clauss Fibrinogen) in the Context of Severe Postpartum Haemorrhage: a Prospective Multicenter Non-interventional Study

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06255002
Acronym
FIB-HPPS
Enrollment
70
Registered
2024-02-12
Start date
2024-06-03
Completion date
2026-03-02
Last updated
2026-05-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Postpartum Hemorrhage

Keywords

Severe postpartum haemorrhage, Fibrinogen concentration, qLabs®FIB Monitoring system, Clauss fibrinogen assay

Brief summary

In France in 2021, 11.6% of deliveries were complicated by a postpartum haemorrhage (PPH), including 3.0% by severe PPH (the bleeding volume exceeds 1000 ml). Severe PPH is the 5th cause of maternal death (8.4% or 1.2 deaths per 100,000 live births). These deaths were considered preventable in 90% of cases. A plasma fibrinogen concentration below 2 g/L is considered as a critical threshold which constitutes a marker of severity of PPH and is significantly associated with the occurrence of severe PPH. Measuring the concentration of fibrinogen using a rapid test, simple to perform and interpret, available in the delivery room could optimize the management of severe PPH. The qLabs®FIB analyzer distributed by the Stago Biocare laboratory for the rapid determination of the fibrinogen concentration at the patient's bedside could meet this objective.

Detailed description

In France in 2021, 11.6% of deliveries were complicated by postpartum hemorrhage (PPH), including 3.0% by severe PPH (the bleeding volume exceeds 1000 ml). Severe PPH is the 5th cause of maternal death (8.4% or 1.2 deaths per 100,000 live births). These deaths were considered preventable in 90% of cases. A plasma fibrinogen concentration below 2 g/L is considered as a critical threshold which constitutes a marker of severity of PPH and is significantly associated with the occurrence of severe PPH. Measuring the concentration of fibrinogen using a rapid test, simple to perform and interpret, available in the delivery room could optimize the management of severe PPH. The qLabs®FIB analyzer distributed by Stago Biocare laboratory for the rapid determination of the fibrinogen concentration at the patient's bedside could meet this objective. The hypothesis of the study is a concordance between the measurement of fibrinogen by the qLabs®FIB Monitoring system and by the Clauss fibrinogen assay in laboratory to identify patients with a fibrinogen level \< 2 g/L. The prospects are to provide an easy-to-use delocalized biology tool for early diagnosis of a fibrinogen concentration \< 2g predictive of an unfavorable evolution in the context of severe PPH.

Interventions

BIOLOGICALFibrinogen concentration by the qLabs®FIB Monitoring system

A drop of blood (\~15 μL) is taken from the blood sample for the complete haemostasis assessment (prothrombin level, activated partial thromboplastin time, fibrinogen). This assessment is part of the usual management of severe postpartum haemorrhage. It is carried out urgently in the hospital's medical biology laboratory at the start of treatment (T1) and during or at the end of treatment of the haemorrhage (T2). This drop of blood will allow the measurement of the fibrinogen concentration by the qLabs®FIB Monitoring system for the study at these two times.

Sponsors

Assistance Publique - Hôpitaux de Paris
Lead SponsorOTHER
URC-CIC Paris Descartes Necker Cochin
CollaboratorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum

Inclusion criteria

Adult patients having been informed of the study and not having objected to their participation and treated for severe postpartum haemorrhage defined as bleeding greater than 1000 ml within 24 hours postpartum, whatever the route delivery (vaginal route and caesarean section).

Exclusion criteria

* Opposition to participation in the study * Presence of a constitutional fibrinogen deficiency * Patients under guardianship or curatorship

Design outcomes

Primary

MeasureTime frameDescription
Agreement between fibrinogen measurement by qLabs®FIB and by the Clauss methodThrough study completion, an average of 1 yearCalculation of the average bias and the 95% limits of agreement between the measurement of qLabs®FIB fibrinogen in the delivery room and Clauss fibrinogen at the medical biology laboratory using the Bland and Altman graphic method. A difference of 0.1 g between the two techniques will be considered acceptable to identify patients with a fibrinogen level \< 2 g/L.

Secondary

MeasureTime frameDescription
Evaluation of the ease of use of qLabs®FIB by the anesthesia teamThrough study completion, an average of 1 yearEase of use of the qLabs®FIB assessed by a numerical scale between 0-10 by the anesthesia team.
Evaluation of the time taken to obtain the fibrinogen concentration using the 2 methodsThrough study completion, an average of 1 yearTime to obtain the fibrinogen result with the qLabs®FIB and the Clauss method at the medical biology laboratory using the emergency circuit proposed by the laboratory.
Evaluation of measurement failure by qLabs®FIBThrough study completion, an average of 1 yearNumber of failed fibrinogen measurements with qLabs®FIB defined as the absence of results returned by the monitor.

Countries

France

Contacts

PRINCIPAL_INVESTIGATORHawa KEITA-MEYER, MD-PhD

Assistance Publique - Hôpitaux de Paris

STUDY_DIRECTORMarc SAMAMA, MD-PhD

Assistance Publique - Hôpitaux de Paris